My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE BASE FILE 2025-09-29
>
Address Records
>
PACIFIC AVE
>
916
>
BASE FILE
>
916 PACIFIC AVE BASE FILE 2025-09-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2025 1:42:29 PM
Creation date
8/18/2025 9:28:15 AM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installation Application <br /> SIGA-CR and SIGA-CRR:modules mount to North American The operation of Signature Series control relays is determined by <br /> 21/2 inch(64 mm)deep 1-gang boxes and 1 t/2 inch(38 mm)deep their sub-type code or"Personality Code." <br /> 4 inch square boxes with 1-gang covers and SIGA-MP mounting <br /> plates.The terminals are suited for#12 to#18 AWG(2.5 mm2 to Personality Code 8:CONTROL RELAY(SIGA-CR/MCR) <br /> 0.75 mm2)wire size. -Dry Contact Output.This setting configures the module to <br /> provide one Form "C" DRY RELAY CONTACT to control Door <br /> Closers, Fans, Dampers, etc. Contact rating is 2.0 amp Q <br /> ✓ Compatible electrical box 24 Vdc;0.5 amp @ 120 Vac(or 0.25A Q 220 Vac for non-UL <br /> applications). Personality Code 8 is assigned at the factory. No <br /> user configuration is required. <br /> Personality Code 8: POLARITY REVERSAL RELAY MODULE <br /> (SIGA-CRR/MCRR).This setting configures the module to <br /> Wall plate,wnite reverse the polarity of its 24 Vdc output. Contact rating is 2.0 <br /> (1 gang) amp Q 24 Vdc(pilot duty). Personality Code 8 is assigned at the <br /> mm factory. No user configuration is required. <br /> a <br /> R c, <br /> 0 <br /> mm, <br /> a Compatibility <br /> M These modules are part of EDWARDS's Signature Series intelligent <br /> Status LEDs processing and control platform.They are compatible with EST3, <br /> m EST3X and iO Series control panels. <br /> LED viewing ports • • <br /> O, <br /> Warnings & Cautions <br /> This module will not operate without electrical power.As fires <br /> SIGA-MCR and SIGA-MCRR:mount the UIO motherboard frequently cause power interruption,we suggest you discuss <br /> inside a suitable EDWARDS enclosure with screws and washers further safeguards with your local fire protection specialist. <br /> provided. Plug the module into any available position on the <br /> motherboard and secure the module to the motherboard with the <br /> captive screws.Wiring connections are made to the terminals on Testing & Maintenance <br /> the motherboard(see wiring diagram). UIO motherboard terminals <br /> are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. The module's automatic self-diagnosis identifies when it is <br /> defective and causes a trouble message.The user-friendly <br /> L11 <br /> maintenance program shows the current state of each module <br /> —ulo Motherboard and other pertinent messages. Single modules may be turned <br /> off(deactivated)temporarily,from the control panel.Availability of <br /> maintenance features is dependent on the fire alarm system used. <br /> -- -- -�--� Scheduled maintenance(Regular or Selected)for proper system <br /> Plug-in(Ulo) operation should be planned to meet the requirements of the <br /> Module Authority Having Jurisdiction(AHJ). Refer to current NFPA 72 and <br /> -- -- fl--"I ULC CAN/ULC 536 standards. <br /> Cabinet or electrical enclosure <br /> Electronic Addressing -The loop controller electronically <br /> addresses each module, saving valuable time during system <br /> commissioning. Setting complicated switches or dials is not <br /> required. Each module has its own unique serial number stored <br /> in its on-board memory.The loop controller identifies each device <br /> on the loop and assigns a"soft"address to each serial number. <br /> If desired,the modules can be addressed using the SIGA-PRO <br /> Signature Program/Service Tool. <br /> EDWARDS recommends that this module be installed according <br /> to latest recognized edition of national and local fire alarm codes. <br /> Page 2 of 6 D A T_ E85001-0239 <br /> Not to be used for installa, purposes. Issue 1.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.