Street Name
PACIFIC AVE
Street Number
916
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Typical Wiring <br /> Modules will accept#18 AWG (0.75mm2), #16(1.Omm2), #14 AWG (1.50mm2)and#12 AWG (2.5mm2)wire sizes. <br /> Note: Sizes#16 AWG (1.Omm2)and#18 AWG(0.75mm2)are preferred for ease of installation. See Signature Loop Controller catalog <br /> sheet for detailed wiring requirement specifications. <br /> Normally- Normally- <br /> Open Common Closed <br /> L447, <br /> TB2 <br /> 8 7 6 <br /> � v c <br /> Red LED O Green LED <br /> (Alarm/Active) (Normal) <br /> 4 3 2 1 <br /> TB1 T T t <br /> T Notes <br /> 0 Refer to Signature Loop Controller Installation <br /> DATA IN <br /> Sheet for wiring specifications. <br /> (+) DATA OUT(+) l <br /> )} Q2 NFPA 72 requires that the SIGA-CR/SIGA-MCR <br /> DATA IN() DATA OUT() be installed in the same room as the device it is <br /> From Signature Controller To Next Device controlling.This requirement may not apply in all <br /> or Previous Device Y markets.Check with your local AHJ for details. <br /> Al Q The SIGA-UI06R and the SIGA-UI02R do not <br /> SIGA-CR Control Relay come with TB14. <br /> ®The SIGA-UI06 does not come with TB8 through <br /> TB13. <br /> Normally Open Common Normally Closed 5�Supervised and power-limited. <br /> © If the source is nonpower-limited,maintain a <br /> space of 1/4 inch from power-limited wiring or use <br /> FPL,FPLP,FPLR,or an equivalent in accordance <br /> with the National Electrical Code. <br /> O2 8 Maximum#12 AWG(2.5mm2)wire. <br /> Q1 2 3 4 Min.#18(0.75mm2). <br /> 1 <br /> Data In+ <br /> Z Q <br /> 4 S B 4 <br /> 3 3 <br /> 2 S 2 <br /> 1 B N(s) 1 <br /> TB7 TB14 <br /> + No connections required for <br /> Data Out MCR.Other modules may <br /> N require connections. <br /> d <br /> z <br /> u� 4 <br /> 3 <br /> 2 <br /> Green LED(Normal) 1 <br /> Red LED(Active) ��00 TB15 <br /> 00 <br /> 1234 <br /> A <br /> No connections required for <br /> MCR.Other modules may <br /> require connections. <br /> SIGA-MCR Control Relay <br /> Page 3 of 6 D ATA S H E E E85001-0239 <br /> Not to be used for installat._ Issue 1.1 <br />