Laserfiche WebLink
INITIATING WIRING RECORD DRAWINGS convergjnt <br /> AS-BUILT/RECORD DRAWING REQUIREMENTS: o o a 0 o O Z O <br /> SIGNATURE LOOP WIRING LIMITATIONS: _- Q ¢ u a i= Fa 0 m a <br /> THE FOLLOWING INFORMATION SHOULD BE RECORDED ON A SEPARATE SET OF o u u z z N a O o <br /> LL <br /> SIGNATURE DUAL DRIVER CONTROLLER MODULES SUPPORTS UP TO 250 DRAWINGS FOR EACH PROJECT: w a F z a Z ,�„ N o o O <br /> INTELLIGENT SIGNATURE DETECTORS AND 250 INTELLIGENT SIGNATURE o a O a O Z O ~ O z O < u O a 450 Shattuck Avenue South,Renton,Washington 98057 <br /> MODULES 1. ANY CHANGES IN THE LOCATION OF ANY ASSOCIATED FIRE ALARM OR = F a F a F a F F F w w F o a u z Phone:425-272-2250 Fax:425-251-0949 <br /> WIRE LENGTH LIMITATIONS: INTERFACE EQUIPMENT.CONTROL PANELS,ANNUNCIATORS,DETECTORS, o d � S L� ¢ S a S a 5 u u w o w z a a <br /> CONTROL RELAYS,INPUT AND OUTPUT MODULES,TERMINAL CABINETS, ,.. z p N p p Q p a p O O u w _ (- z <br /> NON-TWISTED,NON-SHIELDED WIRE ETC. "� p z w z a z u, z z z ,�—� <br /> °�' m z > w w ~ '^ 0 z a o m This d-umentantl the infoeb.n/tlepicfions mnWinedl.hoWn <br /> 16AWG-20pf/FT&4.02 OHMS/1000 FEET 2. ANY CHANGES TO CIRCUIT WIRING.THIS INCLUDES DELETION OR SEQUENCE O F ~ > m m J J w a a o O Q z i3 he e.�iu3i�a Property or con�ergint Teohnoiogie:LLC aria shell <br /> 18AWG-2OpfIFT&6.38 OHMS/1000 FEET ADDITIONAL WIRING RUNS.ANY RE-ROUTING OF CIRCUIT WIRING.ANV F O w o o o o o K °'' m > OJ " be hantllea as proprietary aria wnfitlential information aria must be <br /> DETECTORS ONLY i6AWG-125 DETECTORS-9,275' ADDITIONS OR DELETIONS TO THE NUMBER,LOCATION,AND ORDER OF a a O r n . . > O O D. " z O retumetl upon request.This tlowmenl cannot be reprotlucetl by any <br /> m N a a a w a a z N D, > f° o a a a s ens without the wthen euthodutlon of Convergint Technologies LLC. <br /> MODULES ONLY 16AWG-125 MODULES-7,921' DEVICE WIRING ON A CIRCUIT. 3 O z a _ <br /> DETECTORS AND MODULES i6AWG-125 OF EACH-3,608' 3. ADDRESSES AND/OR LABELS FOR ALL ADDRESSABLE DEVICES. OPERATIONS g o 0>3 a N O a O s u g "+ a <br /> DETECTORS ONLY 18AWG-125 DETECTORS-5,839' 4. CANDELA SETTINGS OF ALL VISUAL NOTIFICATION DEVICES. a a g a g a a ~ a > of O " '>�' <br /> MODULES ONLY 18AWG-125 MODULES-4,986' 5. WATTAGE TAP SETTINGS OF ALL SPEAKER NOTIFICATION DEVICES. z0 O ,w,l O „I u � o 'n z Z a < 11 a ~a V z w <br /> DETECTORS AND MODULES 18AWG-125 OF EACH-2,271' O o z o o O o o Lp Z j a N <br /> ANY CHANGES SHALL BE DISCUSSED WITH CONVERGINT PROJECT MANAGER z o 0 o O o <br /> TWISTED PAIR,NON-SHIELDED WIRE TO ENSURE SYSTEM AND CODE PARAMETERS ARE MET.CONVERGINT SHALL F ¢ p LLO z a a a <br /> 16AWG-36pf/FT&4.02 OHMS 1000 <br /> FEET NOT BE HELD ACCOUNTABLE FOR CHANGES MADE WITHOUT APPROVAL. z >_. > G `- z g J w w F <br /> 18AWG-25pf/FT&6.38 OHMS/1000 FEET o C > F a a p 0 a <br /> DETECTORS ONLY 16AWG-125 DETECTORS-9,275' THIS INFORMATION SHALL BE NEAT AND LEGIBLE WHEN PRESENTED TO THE a a a C > > "' O > <br /> MODULES ONLY 16AWG-125 MODULES-7,921' TECHNICIAN AT THE CONCLUSION OF THE PROJECT.PLEASE NOTE CONTACT > a <br /> DETECTORS AND MODULES 16AWG-125 OF EACH-3,608' INFORMATION ON DRAWINGS FOR INDIVIDUALS WITH FAMILIARITY OF t5 ¢ a <br /> DETECTORS ONLY 18AWG-125 DETECTORS-5,839' INSTALLATION IN THE EVENT QUESTIONS ARISE DURING THE CLOSEOUT <br /> MODULES ONLY 18AWG-125 MODULES-4,986' PROCESS. X X X X X <br /> DETECTORS AND MODULES 18AWG-125 OF EACH-2.271' SMOKE DETECTOR <br /> TWIST 82PflF &4.02EDWIRE POWER REQUIREMENTS X X X X X X <br /> TWIST- PAIR,SHIELD <br /> OHMS/1000 FEET SMOKE DETECTOR-MAIN ELEVATOR LOBBY <br /> 18AWG-58pf/FT&6.38 OHMS/1000 FEET — <br /> DETECTORS ONLY i6AWG-125 DETECTORS-6,098' EACH MAIN FIRE ALARM PANEL REQUIRES(1)120VAC,20AMP DEDICATED SMOKE DETECTOR-ALL OTHER LOBBIES X X X X X X <br /> MODULES ONLY 16AWG-125 MODULES-6,098' CIRCUIT. <br /> DETECTORS AND MODULES i6AWG-125 OF EACH-3,608' ELEV.MACH.RM/TOP OF SHAFT SMOKE <br /> MODULES ONLY 18AWG-125 MODULES-4,986 DETECTOR(5) <br /> DETECTORS ONLY 18AWG-125 DETECTORS-5,839' EACH NAC BOOSTER PANEL REQUIRES(1)120VAC,15AMP DEDICATED CIRCUIT. X X X X X X X <br /> ' <br /> DETECTORS AND MODULES 18AWG-125 OF EACH-2,271' IN BUILDINGS EMPLOYING EMERGENCY STANDBY POWER SYSTEMS,THE FIRE SHUNT TRIP DUAL CIRCUIT HEAT DETECTOR(S) X X X X X X <br /> ALARM SHALL BE SUPPLIED WITH EMERGENCY POWER.THIS IS REQUIRED IN TOP OF SHAFT/MACH.RM. <br /> SIGNATURE 0­LOOP WIRING c-ASS E 0— SIGNATURE DATA LOOP.o-ASS HIGH-RISE AND SMOKE CONTROL APPLICATIONS.ALL OTHER APPLICATIONS <br /> ARE SUBJECT TO LOCAL BUILDING AND ELECTRICAL CODES. SHUNTTRIP POWER MONITOR X X X <br /> aoa,x n o of LaoP�h u u�� WHERE THE FIRE ALARM SYSTEM IS CONNECTED TO EMERGENCY <br /> POWER,THE FIRE ALARM SYSTEM MONITORS THE GENERATOR FOR MANUAL PULL STATION X X X X X <br /> RUNNING,FUEL LOW AND TROUBLE STATES. <br /> s e0 s em <br /> FOR ADDITIONAL DETAILS,REFER TO NFPA 72,CHAPTER 10. GENERAL TROUBLE CONDITION X X X <br /> GENERAL SUPERVISORY CONDITION X X X <br /> HEATDETECTOR X X X X X <br /> DUCT DETECTOR X X X <br /> WATERFLOW SWITCH X X X <br /> 4i .7-_� PRESSURE SWITCH X X X <br /> T-TAPPING.ACCEPTABLE STAR-TAPPING.UNACCEPTABLE <br /> TAMPERSWITCH X X X 1 <br /> NOTIFICATION WIRING X X X <br /> FACP-LOSS OF PRIMARY POWER <br /> SPEAKER CIRCUIT WIRING LIMITATIONS: <br /> WIRE LENGTH LIMITATIONS: <br /> THE MAXIMUM ALLOWABLE WIRE LENGTH IS THE FARTHEST DISTANCE THAT A <br /> SPEAKER CIRCUIT CAN EXTEND FROM THE AMPLIFIER TO THE LAST SPEAKER <br /> WITHOUT LOSING 0.5 dB OF SIGNAL.THE FOLLOWING ARE MAXIMUM DISTANCE <br /> BASED ON APPROXIMATE WATTAGE OF THE SPEAKER CIRCUIT.CIRCUIT LENGTHS <br /> ARE FURTHER BASED ON ORIGINATION OF A CIRCUIT FROM EITHER THE <br /> AMPLIFIER OR FROM THE CCi MODULE. <br /> ALLOWABLE LENGTH AT 25 Vrms,WITH 0.5 dB LOSS <br /> 16AWG-20 WATTS- <br /> 231' <br /> 1 <br /> 6AWG-30 WATTS-154' <br /> 16AWG-40 WATTS-116' <br /> ALLOWABLE LENGTH AT 70 Vrms,WITH 0.5 dB LOSS <br /> 16AWG-20 WATTS- <br /> 1815' <br /> 1 <br /> 6AWG-30 WATTS-1210' <br /> 16AWG-40 WATTS-907' <br /> NAC CIRCUIT(HORN,STROBE)WIRING LIMITATIONS: <br /> FOR 24VDC SYSTEMS,MINIMUM DEVICE OPERATING VOLTAGE IS 16VDC. <br /> VOLTAGE DROP CALCULATIONS ARE BASED ON 16VDC AND POWER SUPPLY <br /> DE-RATED AND ON DEPLETED BATTERY BACKUP PER THE PRESCRIBED PERIOD <br /> OF STANDBY AND ALARM RING TIME.THE VOLTAGE DROP WILL LIMIT THE <br /> CIRCUITS CAPACITY IN ALMOST ALL CASES AND CURRENT CANNOT BE USED AS <br /> THE ONLY CIRCUIT WIRING LIMITATION.ALTERATIONS TO CIRCUIT LENGTH <br /> FROM THOSE CALCULATED MAY CAUSE CIRCUITS TO BE OUT OF THE <br /> TOLERANCES GRANTED BY THE FIRE ALARM CODE.CHANGES TO DEVICE <br /> LOCATION OR CIRCUIT LENGTH SHALL BE COMMUNICATED TO THE CONVERGINT <br /> TEAM. <br /> NAC CIRCUIT WIRING AND ROUTING MUST NOT EXCEED WHAT IS SHOWN ON THE <br /> DESIGN DRAWINGS AND CALCULATIONS.A VOLTAGE DROP TEST IS PART OF <br /> MOST FIRE FINALS AND IS REQUIRED BY NFPA.A FAILED FIRE FINAL MAY <br /> REQUIRE REWIRING OF THE FAILED CIRCUITS. <br /> WIRE RESISTANCE RATINGS USED FOR CALCULATIONS: <br /> 18AWG-13 OHMS PER 1000' <br /> 16AWG-8 OHMS PER 1000, <br /> 14AWG-5.2 OHMS PER 1000' <br /> EXAMPLE: 1.0 AMP CIRCUIT LOAD USING#14 WIRE=409 FEET MAXIMUM. <br /> CLASS A OR B NOTIFICATION WIRING <br /> EOL <br /> FACP <br /> OR EOL RESISTOR ON <br /> NAC NON ADDRESSABLE <br /> CIRCUITS <br /> DEVICE DEVICE <br /> CLASS B,STYLE 4 WIRING <br /> REI JON-DESCWPTIOM DATE <br /> ISSUED FOR PERMIT 02-1-23 OR <br /> FACP I J00150M ISSUED FOR PERMIT <br /> OR <br /> NAC <br /> DEVICE DEVICE <br /> } <br /> a <br /> OIMKP1LtA H. <br /> C) PROJECT DESIGNER: NE 3, <br /> W <br /> Q CLASS A.STYLE 6 WIRING <br /> UAS SHOWN D.TF <br /> N <br /> Q SEPARATION OF CLASS A CIRCUITS-INSTALLATION EXCEPTIONS: <br /> U PROVIDENCE PACIFIC CAMPUS <br /> H CLASS A OUTGOING AND RETURN CONDUCTORS,EXITING AND RETURNING ELEVATOR T.I. <br /> TO THE CONTROL PANEL,ARE TO BE ROUTED SEPARATELY.THE MINIMUM 916 PACIFIC AVE <br /> N <br /> 04 RECOMMENDED SEPARATION IS 1 FT.VERTICALLY AND 4 FT. <br /> 98201 <br /> x HORIZONTALLY.THE FOLLOWING EXCEPTIONS STILL DO NOT ELIMINATE <br /> o THE 2ND PAIR OF WIRES.THEY ALLOW YOU TO USE A SINGLE RACEWAY <br /> M AND ELIMINATE THE SEPARATION FOR THESE CONDITIONS. <br /> H <br /> z 1. WHEN MAXIMUM CABLE,ENCLOSURE,OR RACEWAY IS LESS THAN 10 NOTES <br /> FEET.NO LIMIT TO NUMBER OF DEVICES. <br /> 2. UNLIMITED CONDUIT OR RACEWAY DROP TO AN INDIVIDUAL DEVICE. <br /> () <br /> 3. UNLIMITED CONDUIT OR RACEWAY DROP TO A ROOM NOT FIRE ALARM SYSTEM <br /> Z EXCEEDING 1000 SO,FT.NO LIMIT TO THE NUMBER OF DEVICES. <br /> Q wwG. <br /> o FA-0-2 <br />