Laserfiche WebLink
(DponnER PAD300-H D <br /> ma sYMM of Aftwo Heat Detector <br /> Features <br /> • Selectable Rate of Rise and/or Fixed Heat Detector <br /> • Low Profile <br /> • Reliable Detection Technology <br /> • LED Alarm Indicator G <br /> • Ambient Temperature Listing of 32°F to 150°F <br /> • Simple DIP Switch Address Setting,No Programming Tool r �' <br /> Required <br /> • Magnetic Test Switch <br /> • Product includes 5-year warranty <br /> • UUKL Listed for Smoke Control <br /> 0328-0538 <br /> Description Technical Specifications <br /> The PAD300-HD is a listed analog addressable rate of rise and/or Operating Voltage 24 VDC <br /> fixed temperature heat detector compatible with any fire alarm control <br /> panel that has the Potter Addressable Device(PAD)protocol.The heat Detector Current Draw 300 µA <br /> sensing portion utilizes a proven thermistor for accurate and reliable Alarm Indicator 1 LED <br /> heat detection. The detector and base (not included) are made of a Alarm Set-point Range 135°F to 185°F(57°C to 85°C) <br /> durable plastic in an off-white to blend in with the ceiling. <br /> Rate of Rise Detection 8.3°C/min.15°F/min. <br /> The PAD300-HD is UL listed with a selectable fixed temperature (Selectable Option) ( ) <br /> point from 135' to 185' Fahrenheit and can be used for rate of rise <br /> applications. See detector spacing limitations below. This flexibility Installation Temperature Range 32°F to 150°F(0°C to 66°C) <br /> allows the installer to cover a wide variety of applications with a single <br /> unit. Operating Relative Humidity <br /> The PAD300-HD and the control panel communicate over a proven <br /> Range 0%to 93%INon-condensing) <br /> and robust digital communication path and the system analyzes the Start-up Time Max. 1 sec. <br /> information at the particular device.The total polling speed is less than Maximum Number of Addresses <br /> five(5)seconds,well under the UL requirements. Per Loop 127 <br /> The detector is compatible with any of the PAD300 series detector <br /> bases and simply twists on.The PAD300-HD is addressed using DIP Maximum Number of Lighted 30 <br /> switches in the rear of the detector and can be easily programmed in Indicators in Alarm Per Loop <br /> the field without special tools. <br /> Color Eggshell White <br /> Setting the Address Weight(Without Base) 68 g(2.4 oz) <br /> Each addressable device on the SLC loop must have a unique address Height: 1.5 in(38 mm) <br /> from 1 to 127 to function properly. The address is set using DIP Dimensions(Without Base) Diameter 3.93 in(100mm) <br /> switches. <br /> Before connecting a device to the SLC loop, take the following <br /> precautions to prevent potential damage to SLC or device.Verify the <br /> following: <br /> 1. Power to the device is removed. <br /> 2. Field wiring is correctly installed. <br /> 3. Field wiring has no open or short circuits. <br /> Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br /> 8830210-REV C 6/23 PAGE 1 OF 2 <br />