Laserfiche WebLink
Application Testing & Maintenance <br /> The KI-PD detects extremely small particles of combustion and Each detector automatically identifies when it is dirty or defective <br /> triggers an alarm at the first sign of smoke.Thanks to its high- and causes a"dirty detector" message.The detector's sensitiv- <br /> performance forward-scattering reflective response technology, ity measurement can also be transmitted to the loop controller.A <br /> the photoelectric smoke sensor responds quickly and reliably to sensitivity report may be printed to satisfy NFPA sensitivity mea- <br /> a wide range of fire types, especially slow burning fires fuelled by surements,which must be conducted at the end of the first year <br /> combustibles typically found in modern multi-use buildings. and every two years thereafter. <br /> The user-friendly maintenance program shows the current state <br /> Compatibility of each detector and other pertinent messages. Single detectors <br /> may be turned off temporarily from the control panel.Availability of <br /> The KI-PD detector is compatible with Kidde VS and VM series maintenance features is dependent on the fire alarm system used. <br /> panels. <br /> Accessories <br /> Installation Detector mounting bases have wiring terminals that are acces- <br /> KI Series detector bases mount sible from the"room-side"after mounting the base to the electrical <br /> to North American 1-gang boxes, box.The bases mount to North American 1-gang boxes and to <br /> 3-1/2 inch or 4 inch octagon d 3/2 inch or 4 inch octagon boxes, 1/2 inches(38 mm)deep.They <br /> Self-locking tab also mount to European BESA and 1-gang boxes with 60.3 mm <br /> boxes,and to 4 inch square elec- fixing centers.The KI-SB4, KI-RB4,and KI-IB4 mount to North <br /> trical boxes 1-1/2 inches(38 mm) American 4 inch sq.electrical boxes in addition to the above <br /> deep.They mount to European boxes.They include the GSA-TS4 Trim Skirt,which is used to <br /> BESA and 1-gang boxes with 60.3 cover the"mounting ears"on the base.The KI-ABST mounts to a <br /> mm fixing centers. See mounting ? LED Indicator 4 inch square box only. <br /> base installation and wiring for <br /> more information. o <br /> WWW <br /> Sensing and reporting technology KI-ABST/T/LF KI-SB KI-IB KI-RB GSA-LED <br /> The microprocessor in each detector provides additional benefits- Audible Base Standard Base Isolator Base Relay Base Remote LED <br /> Self-diagnostics and History Log,Automatic Device Mapping, and Remote LED GSA-LED-The remote LED connects to the KI-SB <br /> Fast, Stable Communication. or KI-SB4 Standard Base only. It features a North American size <br /> Self-diagnostics and History Log - Each KI Series detector 1-gang plastic faceplate with a white finish and red alarm LED. <br /> constantly runs self-checks to provide important maintenance in- GSA-TS4 Trim Skirt-Supplied with 4 inch bases, it can also <br /> formation.The results of the self-check are automatically updated be ordered separately to use with the other bases to help hide <br /> and permanently stored in the detector's non-volatile memory surface imperfections not covered by the smaller bases. <br /> Automatic Device Mapping-The loop controller learns where Sounder Bases- KI Series sounder bases are designed for use <br /> each device's serial number address is installed relative to other where localized or group alarm signaling is required. <br /> devices on the circuit.The mapping feature provides supervision • KI-ABST bases provide sounder capability to KI Series heat <br /> of each device's installed location to prevent a detector from being and smoke detectors.They are not intended for use with <br /> reinstalled(after cleaning etc.)in a different location from where it combination carbon monoxide detectors in Fire-plus-CO <br /> mode. <br /> was originally. e KI-ABDT bases provide sounder capability to KI Series <br /> Fast Stable Communication-On-board intelligence means less smoke and heat detectors, as well as carbon monoxide <br /> information needs to be sent between the detector and the loop detectors when used with a GSA-T3T4 Temporal Pattern <br /> controller. Other than regular supervisory polling response,the Generator. <br /> detector only needs to communicate with the loop controller when . KI-ABLT bases provide 520 Hz low frequency sounder <br /> it has something new to report. capability to KI Series smoke and heat detectors, as well as <br /> carbon monoxide detectors when used with a GSA-T3T4 <br /> Temporal Pattern Generator.The KI-ABLT is suitable for ap- <br /> plications requiring low frequency audible tones. <br /> Page 2 of 4 DATA SHEET K85001-0646 <br /> Not to be used for installation purposes. Issue 1 <br />