6801 SEAWAY BLVD 2024 MCKESSON CORP 2025-09-12
>
Address Records
>
SEAWAY BLVD
>
6801
>
MCKESSON CORP
>
6801 SEAWAY BLVD 2024 MCKESSON CORP 2025-09-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2025 1:29:26 PM
Creation date
8/18/2025 11:00:01 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
6801
Tenant Name
MCKESSON CORP
Year
2024
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Typical Wiring <br /> The detector mounting bases accept#18 AWG(0.75mm2),#16 Audible Sounder Bases, Fire Mode <br /> (1.Omm2), #14 AWG(1.5mm2)I and#12 AWG(2.5mm2)wire sizes. AB4GT,AB4G,AB4G-LF sounder bases <br /> Sizes#16 AWG(1.Omm2)and#18 AWG(0.75mm2)are preferred <br /> for ease of installation. <br /> Standard Detector Base KI-SB KI-SB4 KI-ABDT, 0 0 OutputKI-ABIL <br /> e r KI-ABST, ® ® Output Mode <br /> KI-ABLT: Jumper cuts Default=Fire <br /> This is the basic mounting base Remote LED Volume Setting Cut/remove jumper for <br /> for Kidde KI Series detectors. Max resistance Default=High Fire plus CO <br /> The GSA-LED Remote LED is wire Cut/remove <br /> _ exceed jumper for KI-ABST: <br /> supported by this + must <br /> not 10 ohms low dEl ® ® Tone Setting <br /> Base. O 5 , DATA.DATA-DATA. Default=Temporal <br /> Tenn Description sic+ SIG- OUT IN IN/OUT Cut/remove jumper for <br /> 1 Not Used Steady <br /> 2 DATA IN/OUT(+) O <br /> O�` : <br /> 3 Not Used KI-ABDT <br /> 4 DATA IN(-) Not Used <br /> 4 Remote LED(-) DATA IN 1-) 0 e O DATA OUT I-) <br /> 5 Remote LED(+) <br /> 6 Not Used <br /> 7 DATA OUT(-) DATA IN 1+) DATA OUT(A 24 Vdc in <br /> From Signature Controller To Next Device From power supply 24 Vdc out <br /> or Previous Device or previous base + + To next base or EOL relay <br /> 4 <br /> Data in _ Data out <br /> Isolator Detector Base, KI-IB, KI-1134 From KI Device Controller + + to next KI Series device <br /> or previous device <br /> This base includes a built-in line fault isolator for use on Class A <br /> circuits.A detector must be installed for it to operate.The isolator <br /> base does not support the GSA-LED Remote LED. Warnings & Cautions <br /> The isolator operates as follows: <br /> O o 6 This detector does not operate without electrical power.As <br /> -a short on the line causes all iso- o O fires frequently cause power interruption, discuss further <br /> lators to open within 23 msec ® o° safeguards with the local fire protection specialist. <br /> -at 10 msec intervals, �°o <br /> beginning on one side ® °�` This detector does not sense fires in areas where smoke <br /> of the Class A DATA IN(-) z DATA OUT(-) cannot reach the detector. Smoke from fires in walls, roofs, <br /> circuit nearest the loop or on the opposite side of closed doors may not reach the <br /> controller,the isolators detector. <br /> close to provide the DATA IN(+) DATA OUT(+) <br /> From Signature Controller To Next Device <br /> next isolator down the or Previous Device • Photoelectric detectors have a wide range of fire-sensing <br /> line with power Term Description capabilities and are best suited for detecting slow, smolder- <br /> 1 Not Used <br /> -when the isolator next 2 DATA IN/OUT(+) ing fires. <br /> to the short closes,it reopens within 10 4 DATA <br /> )Used <br /> msec. 5 Not Used In Canada, install according to CAN/ULC-S524 Standard for <br /> 6 DATA OUT the Installation of Fire Alarm Systems, CSA C22.1 Canadian <br /> The process repeats beginning on the 7 Not Used Electrical Code,and the local authority having jurisdiction. <br /> other side of the loop controller. <br /> Relay Detector Base, KI-RB, KI-RB4 <br /> Normally-Normally- <br /> Common Closed Open <br /> This base includes a relay. Nor- <br /> mally Open or Normally Closed <br /> operation is selected during <br /> installation.The dry contact is 0 5 6 <br /> rated for 1 amp(pilot duty)Q o <br /> 30 Vdc.The relay's position is <br /> supervised to avoid accidentally <br /> jarring it out of position.The KI-RB DATA IN(-) Zo DATA OUTc-) <br /> can be operated as a control <br /> relay if programmed to do so at DATA IN(+) To DATA <br /> Device <br /> From Signature Controller <br /> the control panel.The relay base or Prevlow Device <br /> support the GSA-LED Term Description <br /> does not su <br /> pp 1 Normally Open <br /> Remote LED. CONTACT RATING 2 DATA IN/OUT(+) <br /> 1.0 Amp @ 30 VDC 3 Common <br /> (Pilot Duty) 4 DATA IN(-) <br /> 5 Not Used <br /> 6 Normally-Closed <br /> 7 DATA OUT(-) <br /> Page 3 of 4 DATA SHEET K85001-0646 <br /> Not to be used for installation purposes. Issue 1 <br />