6801 SEAWAY BLVD 2024 MCKESSON CORP 2025-09-12
>
Address Records
>
SEAWAY BLVD
>
6801
>
MCKESSON CORP
>
6801 SEAWAY BLVD 2024 MCKESSON CORP 2025-09-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2025 1:29:26 PM
Creation date
8/18/2025 11:00:01 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
6801
Tenant Name
MCKESSON CORP
Year
2024
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Wiring & Configuration <br /> Device loop Auxiliary&smoke power outputs(TB3) <br /> The system provides one device loop circuit with a total capacity The control panel provides two auxiliary power TB3 <br /> of 125 detectors and 125 module addresses.The loop circuit is outputs that can be used for powering ancillary <br /> supervised for opens, shorts, and grounds. equipment such as remote annunciators and two No <br /> (1)wire smoke detectors. Aux 2 can be software � NC <br /> Circuit VS4 VS1 selected to operate continuously.The circuit is <br /> specifications <br /> Device loops One Class B or A One Class B or A loop, supervised for shorts and grounds. <br /> loop,supporting125 supporting 64 devices of (2) NO <br /> pp 9 Circuit specifications <br /> detectors and 125 any kind. Circuit voltage 21.9 to 28.3 V <br /> modules.Expandable to range (2) NC <br /> four loops. I Resettable circuit 24 VDC nominal at 500 mA (3) <br /> Communication Maximum 20 V peak-to-peak (Aux power 2) NO <br /> line voltage Continuous circuit 24 VDC nominal at 500 mA. <br /> Circuit current 0.5 A max (Aux power 1) Use this circuit for powering Q <br /> Circuit 660 total,0.5 NF,max two-wire smoke detectors. <br /> impedance (4) 0 <br /> Isolators 64 maximum Note:Any current above 0.5 amp connected to both Aux <br /> 1 and 2 will reduce the total available NAC power by that O <br /> Signal Supported on a system-wide basis(all device loops) amount. <br /> Synchronization when using an addressable notification appliance (1)Trouble <br /> circuit(NAC)module and Genesis or Enhanced <br /> Integrity notification appliances. (2)Supervisory <br /> Alarm,trouble,and supervisory relay(TB3) (3)Alarm <br /> Class 6 wiring ClassAwiring The trouble relay is normally-open, held closed, <br /> and opens on any trouble event or when the (4)Smoke/Aux <br /> SLC A Data Line SLC A panel is de-energized.The supervisory relay is <br /> normally-open, and closes on any supervisory <br /> SLC B + + + SLC B ,( ]PC3:T� d]v?E <br /> event.The alarm relay changes over on any <br /> Loop Loop Loop cerd device device Loop card Data Lined alarm event. <br /> Relay specifications <br /> Alarm Trouble Supervisory <br /> Notification appliance circuits(TB2) Type Form C Form A <br /> VS4 control panels come equipped with four notification appliance Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive <br /> circuits.VS1 control panels come with two NACs. Each circuit can Relay circuits can only be connected to power-limited sources. <br /> be individually configured for continuous,temporal, synchronized, <br /> and coded output. <br /> Specifications VS4 VS1 Annunciator loop(TB4) <br /> Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A The control panel provides a connection for up to eight serially <br /> with SA-CLA module driven and supervised remote annunciators. <br /> Voltage 24 VFWR <br /> Current 6.0 A total,2.5 A max. 3.75 A total,2.5 A max. Circuit specifications <br /> per circuit at 120/230 per circuit at 120/230 Device loops Class B(Style Y)or Class A(Style Z) <br /> VAC 60 Hz. VAC 60 Hz. Circuit voltage 2.55 V <br /> 5.0 A total,2.5 A max. 3.0 A total,2.5 A max. Circuit current 30 mA max <br /> per circuit at 230 VAC per circuit at 230 VAC Circuit Up to 8 annunciators or 4000 feet <br /> 50 Hz. 50 Hz. impedance <br /> Impedance 26 n total,0.35 pF max <br /> EOLR 15 K O,1/2 W Class B Class A <br /> Synchronization Supported system-wide <br /> Channel Channel Channel Channel <br /> Class E wiring Class A wiring TB4 TB4 <br /> o NAC1- + + (2) NAC1- + + <br /> NAC1+ _ _ 0 NAC1+ _ _ Annunciator Annunciator <br /> NAC2- + + EOLR 0 NAC2 + + CHI(+)IN CH1(+)IN <br /> NAC2+ _ _ 0 NAC2+ CHI(-)IN CHI(-)IN <br /> TB2 TB2 <br /> 0 NAC3- + + �CH2(+)IN CH2(+)IN <br /> NAC3+ _ EOLR 0+ &CH2(-)IN CH2(-)IN <br /> NAC4- + + - <br /> NAC4+ a 13 _0 + <br /> TB6 TB6 <br /> Marking indicates output signal polarity when the circuit is active.Polarity reverses <br /> when the circuit is not active.Wire notification appliances accordingly.Notification <br /> appliance polarity shown in active state. <br /> c <br /> Page 4 of 8 DATA S H, V85005-0135 <br /> Not to be used for insta Issue 1 6 <br />