Laserfiche WebLink
Option Cards <br /> Kidde VS Series panels are supported by a complete line of mod- RZI16-2 Remote Zone Interface Module <br /> ules and related equipment that enhance performance and extend <br /> system capabilities. Option cards plug directly into the control :a_ <br /> panel main circuit board or are connected to it with a ribbon cable.After installation,terminals remain accessible.The cabinet pro-vides ample room for wire routing, keeping wiring neat at all times. <br /> o <br /> Single and Dual Loop Controller Cards The RZI16-2 Addressable Remote Zone Interface Module is an <br /> The V-SLC2-1 is a single loop controller card that can be used addressable device that provides connections for sixteen Class B <br /> with the VS1 as a replacement for the standard 64-point loop, or Initiating Device Circuits and two Class B Supervised Output <br /> with the VS4 as a 250-point expansion module. Circuits.The inputs and outputs can be configured individually for <br /> The V-SLC2-2 is a 500-point dual loop controller card for the VS4 several device types. <br /> that provides two IDC circuits, each with 125 detector addresses The RZI16-2 requires 18 consecutive addresses on the Signaling <br /> and 125 module addresses. Line Circuit(SLC).Addresses are assigned electronically.There are <br /> no address switches to set. <br /> Specifications V-SLC2-1 V-SLC2-2 <br /> Device Addresses VS4:one loop,250 VS4:two loops,500 The RZI16-2 incorporates two 8-segment DIP switches that are <br /> device addresses device addresses used to select the Alarm or Supervisory default device type for <br /> VS1:64 addresses each of the 16 IDC circuits.The module also includes one 4-seg- <br /> Wiring Class B or Class A ment DIP switch used to select the default Relay or NAC output <br /> Operating Voltage 24 VDC device type. Device types other than the default are accomplished <br /> Operating Current Standby:55 mA Standby:45 mA through programming. <br /> (fully loaded loop) Alarm:80 mA Alarm:70 mA <br /> Note:These ratings do not include the use of two-wire smoke modules. RZI16-2 Specifications <br /> Communication Line Max.20.6 V peak-to-peak Voltage <br /> Voltage 24V/Aux nominal: 24 VDC <br /> Terminal Rating 12 to 18 AWG(0.75 to 2.5 mmz) Supervisory current: 250 mA at 24 VDC nominal <br /> Alarm current: 1000 mA <br /> Circuit Current 0.5 A max. 24V/Aux minimum: 18.4 VDC <br /> Max total loop 66 Q 24V/Aux maximum: 26.4 VDC <br /> resistance NAC1, NAC2 nominal: 24 VDC <br /> Max total loop 0.5 uF Current <br /> capacitance Standby current <br /> Isolators 64 isolators maximum per loop(total both for 4.7 k EOL(U.S.) 4.8 mA/circuit <br /> isolator bases and modules) Standby current for <br /> Ground Fault 0 to 5 kn 3.9 k EOL(Canada) 5.7 mA/circuit <br /> Impedance Alarm current <br /> Operating 32 to 120°F(0 to 49°C) at nominal voltage 31.1 mA/circuit <br /> Environment 0 to 93%noncondensing at 90°F(32°C) Relay outputs <br /> Quantity 2 <br /> Type Rating(pilot duty) Programmable 24 VDC at 2.5 A <br /> Input circuit wiring 25 D per wire <br /> SA-ETH Ethernet Interface Card resistance <br /> SA-ETH wiring The SA-ETH card provides a Initiating device circuits <br /> To network standard 10/100 Base T Ether- Quantity 16 <br /> Network cable fg connection <br /> net network connection for EOL resistor 4.7 1<4(U.S.);3.9 1<4 Canada <br /> connecting to an intranet,a local Zone voltage 22.78 V for 4.7 kO(U.S.) <br /> I network, or the Internet.The 22.08 V for 3.9 kO(Canada) <br /> + card can be used to download Alarm current 31.1 mA/channel at nominal voltage <br /> Alarm impedance range <680 f2 <br /> 0l�lf� configuration programming from Trouble impedance range >5.55 kf2 <br /> ° ® the VS-CU to the panel. Supervised output circuits <br /> ❑n The Ethernet card is installed on EOL resistor 15<0 <br /> ® the plastic assembly and con- Quantity 2 <br /> ® Short circuit detection <2.6 kf2 <br /> nects to the main circuit board Open circuit detection >61.9 k0 <br /> Ethernet card via a ribbon cable. Contact ratings 24 VDC at 2.5 A(5 A for two NACs) <br /> SA-ETH specifications Compatible cabinets MFC(A),VS4,APS <br /> Ethernet 10/100 Base T <br /> Operating environment <br /> Temperature 32 to 120°F(0 to 49°C) <br /> Humidity 0 to 93%RH,noncondensing at 90°F <br /> (32°C) <br /> Page 5 of 8 DATA SF. V85005-0135 <br /> Not to be used for instz Issue 1 <br />