My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6801 SEAWAY BLVD 2024 MCKESSON CORP 2025-09-12
>
Address Records
>
SEAWAY BLVD
>
6801
>
MCKESSON CORP
>
6801 SEAWAY BLVD 2024 MCKESSON CORP 2025-09-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2025 1:29:26 PM
Creation date
8/18/2025 11:00:01 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
6801
Tenant Name
MCKESSON CORP
Year
2024
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Option Cards <br /> Kidde VS Series panels are supported by a complete line of mod- RZI16-2 Remote Zone Interface Module <br /> ules and related equipment that enhance performance and extend <br /> system capabilities. Option cards plug directly into the control :a_ <br /> panel main circuit board or are connected to it with a ribbon cable.After installation,terminals remain accessible.The cabinet pro-vides ample room for wire routing, keeping wiring neat at all times. <br /> o <br /> Single and Dual Loop Controller Cards The RZI16-2 Addressable Remote Zone Interface Module is an <br /> The V-SLC2-1 is a single loop controller card that can be used addressable device that provides connections for sixteen Class B <br /> with the VS1 as a replacement for the standard 64-point loop, or Initiating Device Circuits and two Class B Supervised Output <br /> with the VS4 as a 250-point expansion module. Circuits.The inputs and outputs can be configured individually for <br /> The V-SLC2-2 is a 500-point dual loop controller card for the VS4 several device types. <br /> that provides two IDC circuits, each with 125 detector addresses The RZI16-2 requires 18 consecutive addresses on the Signaling <br /> and 125 module addresses. Line Circuit(SLC).Addresses are assigned electronically.There are <br /> no address switches to set. <br /> Specifications V-SLC2-1 V-SLC2-2 <br /> Device Addresses VS4:one loop,250 VS4:two loops,500 The RZI16-2 incorporates two 8-segment DIP switches that are <br /> device addresses device addresses used to select the Alarm or Supervisory default device type for <br /> VS1:64 addresses each of the 16 IDC circuits.The module also includes one 4-seg- <br /> Wiring Class B or Class A ment DIP switch used to select the default Relay or NAC output <br /> Operating Voltage 24 VDC device type. Device types other than the default are accomplished <br /> Operating Current Standby:55 mA Standby:45 mA through programming. <br /> (fully loaded loop) Alarm:80 mA Alarm:70 mA <br /> Note:These ratings do not include the use of two-wire smoke modules. RZI16-2 Specifications <br /> Communication Line Max.20.6 V peak-to-peak Voltage <br /> Voltage 24V/Aux nominal: 24 VDC <br /> Terminal Rating 12 to 18 AWG(0.75 to 2.5 mmz) Supervisory current: 250 mA at 24 VDC nominal <br /> Alarm current: 1000 mA <br /> Circuit Current 0.5 A max. 24V/Aux minimum: 18.4 VDC <br /> Max total loop 66 Q 24V/Aux maximum: 26.4 VDC <br /> resistance NAC1, NAC2 nominal: 24 VDC <br /> Max total loop 0.5 uF Current <br /> capacitance Standby current <br /> Isolators 64 isolators maximum per loop(total both for 4.7 k EOL(U.S.) 4.8 mA/circuit <br /> isolator bases and modules) Standby current for <br /> Ground Fault 0 to 5 kn 3.9 k EOL(Canada) 5.7 mA/circuit <br /> Impedance Alarm current <br /> Operating 32 to 120°F(0 to 49°C) at nominal voltage 31.1 mA/circuit <br /> Environment 0 to 93%noncondensing at 90°F(32°C) Relay outputs <br /> Quantity 2 <br /> Type Rating(pilot duty) Programmable 24 VDC at 2.5 A <br /> Input circuit wiring 25 D per wire <br /> SA-ETH Ethernet Interface Card resistance <br /> SA-ETH wiring The SA-ETH card provides a Initiating device circuits <br /> To network standard 10/100 Base T Ether- Quantity 16 <br /> Network cable fg connection <br /> net network connection for EOL resistor 4.7 1<4(U.S.);3.9 1<4 Canada <br /> connecting to an intranet,a local Zone voltage 22.78 V for 4.7 kO(U.S.) <br /> I network, or the Internet.The 22.08 V for 3.9 kO(Canada) <br /> + card can be used to download Alarm current 31.1 mA/channel at nominal voltage <br /> Alarm impedance range <680 f2 <br /> 0l�lf� configuration programming from Trouble impedance range >5.55 kf2 <br /> ° ® the VS-CU to the panel. Supervised output circuits <br /> ❑n The Ethernet card is installed on EOL resistor 15<0 <br /> ® the plastic assembly and con- Quantity 2 <br /> ® Short circuit detection <2.6 kf2 <br /> nects to the main circuit board Open circuit detection >61.9 k0 <br /> Ethernet card via a ribbon cable. Contact ratings 24 VDC at 2.5 A(5 A for two NACs) <br /> SA-ETH specifications Compatible cabinets MFC(A),VS4,APS <br /> Ethernet 10/100 Base T <br /> Operating environment <br /> Temperature 32 to 120°F(0 to 49°C) <br /> Humidity 0 to 93%RH,noncondensing at 90°F <br /> (32°C) <br /> Page 5 of 8 DATA SF. V85005-0135 <br /> Not to be used for instz Issue 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.