My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-27 2025-09-09
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-27
>
3003 W CASINO RD BLDG 40-27 2025-09-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/9/2025 3:40:05 PM
Creation date
8/18/2025 11:20:33 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-27
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Seatronics, Inc. Boeing 40-27 Elevator project Section 1 <br /> Job: 10403203 Fire Alarm System Submittal Manual Page 3 <br /> 2. FAULT/TROUBLE CONDITIONS: <br /> 2.1 Conditions in the system that may cause failure, or impair operation of the system shall cause the <br /> following: <br /> a. Cause the TROUBLE indicator lamp on the FACP to illuminate. <br /> b. Cause the internal sounder device in the FACP to activate. <br /> c. Display proper message on FACP LCD display with TROUBLE location information. <br /> d. Display trouble point location on the remote annunciators <br /> e. Transmit a TROUBLE signal to CenturyLink's remote monitoring station. <br /> f. Activate the FACP digital dialer/communicator and transmit a TROUBLE signal to the Central <br /> Station monitoring company. <br /> The following is an abbreviated list of the types of faults that will cause a trouble condition to report <br /> to the FACP. <br /> a. Open, shorted or grounded wiring on any detection circuit. <br /> b. Open, shorted or grounded wiring on any manual circuit. <br /> c. Any missing or removed addressable device such as smoke detectors, point monitoring <br /> modules or manual stations. <br /> d. Open, shorted or grounded wiring on any NAC (horn/strobe) circuit. <br /> e. Activation of any panel "Bypass" or"Override"function. <br /> f. Control Panel stand-by battery fault. <br /> g. Loss of primary 120 VAC power to panel for more than 90 seconds. <br /> h. Loss of 24VDC power to the flame detector in the generator building. <br /> i. Failure of the system dialer/communicator to properly"check-in" to the Central Station <br /> monitoring company once every 24 hours or loss of either or both phone lines connected to the <br /> dialer. <br /> End <br /> Seatronics, Inc. PO BOX 1138 Auburn, WA 98001 253-939-6060 <br />
The URL can be used to link to this page
Your browser does not support the video tag.