Laserfiche WebLink
Mr. Jeffery Kildare <br /> Plan Check Number: B2209-004 Second Building Review <br /> March 15, 2023 <br /> 3. Footing depth should be minimum 18" per the frost line depth. See IRC Table R301.2(1) and <br /> EMC Chapter 16.01.010(J). <br /> 4. See the West Wall on Sheet S101. Per IRC Table R602.3(5), the laterally unsupported stud <br /> height is maximum 10'. IRC Section R602.3.1 Exception 2 allows for studs spaced at 16"on <br /> center to have a maximum height of 18' however the studs supporting a roof load cannot have <br /> more than 6'tributary length. An alternative design should be provided that complies with <br /> Table R602.3(5) or R602.3.1 Exception 2. <br /> This review has been performed for general compliance with the building codes as adopted and <br /> amended by the state of Washington and the city of Everett. Corrections and comments made <br /> during the review process do not relieve the project from compliance with code and permit <br /> requirements. The designers-of-record are responsible for a complete design in accordance with <br /> the laws of the state of Washington. <br /> If you have any questions or require additional clarification, please contact us. <br /> Sincerely, <br /> Ryan Hammer <br /> Residential Plans Examiner <br /> (425)257-7299 <br /> rhammer@everettwa.gov <br /> S:\RHammer\2023 Reviews\B2209-004_R1.docx <br /> 0 3200 Cedar Street © 425.257.8810 O permitservices@everettwa.gov <br /> Everett, WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 3 of 3 <br />