My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
607 SE EVERETT MALL WAY MIS ANTOJITOS 2025-09-10
>
Address Records
>
SE EVERETT MALL WAY
>
607
>
MIS ANTOJITOS
>
607 SE EVERETT MALL WAY MIS ANTOJITOS 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 1:11:53 PM
Creation date
8/19/2025 10:00:34 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
607
Tenant Name
MIS ANTOJITOS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
T&D Weaver Construction <br /> Plan Check Number: M2303-045, First Building Review <br /> March 21, 2023 <br /> 2. Roof Plan 1/1-1-04 shows a new MUA fan centered on the framing. The following comments <br /> should be addressed: <br /> a. The weight of the unit should be specified in the schedule on Sheet H-07. See IBC Section <br /> 1603.1.8. <br /> b. Calculations should be submitted for review substantiating the capacity of the roof framing <br /> to support the new rooftop equipment, including the underhung hood, in addition existing <br /> dead and roof loads (e.g., snow, etc.). See IBC Section 1604.2. <br /> 3. The hood should comply with the minimum 18-inch required clearance per IMC Section 507.2.6. <br /> The clearance is required on all sides and the top. Alternatively, the drawings should specify <br /> construction complying with the reduced clearances per Table 308.4.2. Note that modifications <br /> to the building structure are required to be performed as part of the Building permit application <br /> per comments above. <br /> 4. Continuing with the previous comment, the exhaust duct for the hood is required to provide the <br /> minimum 18-inch required clearance per IMC Section 506.3.6. Alternatively, construction per <br /> one of the exceptions should be specified. <br /> 5. Details specifying the vertical support and lateral restraint for the hood should be included in <br /> the drawings. The details should be specific to the current project; the manufacturer's generic <br /> typical details do not satisfy this requirement. See IBC Sections 1603.1, 1604.2, and 1604.4. <br /> 6. The upblast exhaust fan details on Sheet H-07 should specify a flexible electrical cable and <br /> restraint. See IMC Section 506.5.4. <br /> This review has been performed for general compliance with the building codes as adopted and <br /> amended by the state of Washington and the city of Everett. Corrections and comments made <br /> during the review process do not relieve the project from compliance with code and permit <br /> requirements. The designers-of-record are responsible for a complete design in accordance with <br /> the laws of the state of Washington. <br /> If you have any questions or require additional clarification, please contact us. <br /> Respectfully, <br /> Drew Martin, P.E., S.E. <br /> Associate Engineer/ Commercial Plans Examiner <br /> (425)257-8813 <br /> dmartin@everettwa.gov <br /> S:\BMartin\2023\M2303-045_R1.docx <br /> S <br /> 3200 Cedar Street 425.257.8810 everetteps@everettwa.gov <br /> Everett,WA 98201 425.257,8857 fax everettwa.gov/permits <br /> Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.