Laserfiche WebLink
(E) POTTER VSR <br /> The Symbol of Protection Vane Type Waterflow Alarm Switch W/Retard <br /> Features Permit#: FA2501-007 <br /> Site Address: 3003 W Casino Rd <br /> • Assembled in USA Applicant: Alexander Gow(Elec)Equip Co <br /> • 0-90 second field replaceable time delay retard Application Date: 01/12/2025 <br /> • Easy to read retard time delay adjustment knob Description: Monitor WF and Tamper switch <br /> • UL Listed models for 2"-6"steel pipe schedules 5 through 40 with existing fire alarm <br /> • UL Listed and FM approved models for 2"-8"steel pipe schedules Review Date: 01/13/2025 <br /> 10 through 40 <br /> • Two SPDT(form C)contacts <br /> • Weatherproof <br /> • Easy to read wire terminal designations <br /> AWARNING <br /> • Installation must be performed by qualified personnel and in <br /> accordance with all national and local codes and ordinances. � EVEeETT ; <br /> • Shock hazard.Disconnect power source before servicing.Serious EVERETT <br /> injury or death could result. Everett Fire Dept.Permit Review <br /> • Risk of explosion.Not for use in hazardous locations.Serious Status:Approved <br /> injury or death could result. Reviewed By:kbrown <br /> 01/13/2025 10:46:48 <br /> CAUTION AM <br /> Waterflow switches that are monitoring wet pipe sprinkler systems shall OPC <br /> r SIGNALING <br /> not be used as the sole initiating device to discharge AFFF, deluge, ;< Oor chemical suppression systems. Waterflow switches used for this C L C L US <br /> application may result in unintended discharges caused by surges, APPROVED LISTED <br /> trapped air,or short retard times. <br /> Description Technical Specifications <br /> The Model VSR is a vane type waterflow switch for use on wet <br /> sprinkler systems. It is UL Listed for use on a steel pipe; schedules 5 Conduit Two knockouts provided for 1/2"conduit.Individual <br /> through 40,sizes 2"-6"and is UL Listed and FM Approved for use on Entrances switch compartments suitable for dissimilar voltages <br /> steel pipe; schedules 10 through 40,sizes 2"thru 8"(50 mm thru 200 Two sets of SPDT(Form C) <br /> mm). LPC approved sizes are 2" thru 8" (50 mm thru 200 mm). See Contact 10.0 Amps at 125/250VAC <br /> Ordering Information chart. Ratings 2.0 Amps at 30VDC Resistive <br /> The VSR may also be used as a sectional waterflow detector on large 10 mAmps min.at 24VDC <br /> systems.The VSR contains two single pole,double throw,snap action Cover-Weather/UV/Flame Resistant High Impact <br /> switches and an adjustable,instantly recycling pneumatic retard. The Enclosure Composite <br /> switches are actuated when a flow of 10 GPM(38 LPM)or more occurs Base-Die-cast aluminum <br /> downstream of the device. The flow condition must exist for a period NEMA 4/IP54 Rated Enclosure suitable for indoor or <br /> of time necessary to overcome the selected retard period. outdoor use with factory installed gasket when used with <br /> Environmental appropriate conduit fitting. <br /> Enclosure Specifications Temperature Range: 40°F-120°F,(4.5°C-49°C)-UL <br /> The VSR switches and retard device are enclosed in a weather/UV/ Non-corrosive sleeve factory installed in saddle. <br /> flame resistant high impact composite plastic. The cover is held in Flow <br /> place with two tamper resistant screws which require a special key Sensitivity <br /> for removal. A field installable cover tamper switch is available as Range for 4-10 GPM(15-38 LPM)-UL <br /> an option which may be used to indicate unauthorized removal of Signal <br /> the cover. See bulletin number 5401103 for installation instructions Maximum 18 FPS(5.5 m/s) <br /> of this switch. Surge <br /> Service 450 PSI(31 BAR)-UL <br /> Pressure <br /> Automatic Sprinkler NFPA-13 <br /> This document contains important information on the installation Service Use One or two family dwelling NFPA-13D <br /> Residential occupancy up to four stories NFPA-13R <br /> and operation of the VSR.Please read all instructions carefully and National Fire Alarm Code NFPA-72 <br /> notify the building owner or their authorized representative before <br /> any work is done on the fire sprinkler or fire alarm system.A copy Specifications subject to change without notice. <br /> of this document is required by NFPA 72 to be maintained on site. <br /> Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br /> 5401146-REV N 10/21 PAGE 1 OF 5 <br />