3003 W CASINO RD 2025 BLDG 40-53 Plans 2025-08-19
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-53
>
Plans
>
3003 W CASINO RD 2025 BLDG 40-53 Plans 2025-08-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2025 12:00:53 PM
Creation date
8/19/2025 12:00:39 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-53
Permit
FA2501-007
Year
2025
Notes
MONITOR WF AND TAMPER SWITCH WITH EXISTING FIRE ALARM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(E) POTTER VS R <br /> The Symbol of Protection Vane Type Waterflow Alarm Switch W/Retard <br /> Installation (see Fig. 1) <br /> These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will <br /> be accessible. The device should not be installed within 6" (15 cm)of a fitting which changes the direction of the waterflow or within 24" (60 cm) <br /> of a valve or drain. <br /> NOTE:Do not leave cover off for an extended period of time. <br /> Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill(see Fig. 1).Clean the inside pipe of all growth or other material <br /> for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. <br /> Insert the vane so that the arrow on the saddle points in the direction of the waterflow. Take care not to damage the non-corrosive bushing in the <br /> saddle.The bushing should fit inside the hole in the pipe.Install the saddle strap and tighten nuts alternately to required torque(see the chart in Fig. <br /> 1).The vane must not rub the inside of the pipe or bind in any way. <br /> A CAUTION <br /> Do not trim the paddle.Failure to follow these instructions may prevent the device from operating and will void the warranty.Do not obstruct or otherwise prevent the trip <br /> stem of the flow switch from moving when water flows as this could damage the flow switch and prevent an alarm.If an alarm is not desired,a qualified technician should <br /> disable the alarms stem. <br /> Fig.1 Retard Adjustment <br /> DO NOT LEAVE COVER OFF FOR <br /> AN EXTENDED PERrOD OF TIME The delay can be adjusted by rotating the retard adjustment knob <br /> from 0 to the max setting(60-90 seconds).The time delay should be <br /> set at the minimum required to prevent false alarms <br /> TIGHTEN NUTS <br /> A1,TERNATELY CAUTION <br /> �/ Hole must be drilled perpendicular to the pipe and vertically centered <br /> o Refer to the Compatible Pipe/Installation Requirements chart for size <br /> MOUNT ON PIPE SO CO1T0Ct IriCO1TeCt <br /> ARROW ON SADDLE O <br /> POINTS IN DIRECTION <br /> OF WATERFLOW <br /> SOmm <br /> ROLL PADDLE IN <br /> OPPOSITE DIRECTION ADAPTER ADAPTER <br /> DIRECTION OF OF WATERFLOW <br /> WATERFLOW <br /> (Flowing water activates 20mm 2-MAX. <br /> device in one direction only.) DN50 ONLY <br /> DWG IfA6-II USE(2)5180162 ADAPTERS AS SHOWN ABOVE <br /> Compatible Pipe/Installation Requirements <br /> Model Nominal Pipe Nominal Pipe Pipe Wall Thickness Hole Size U-Bolt Nuts <br /> Size O.D. Lightwall Schedule 10(UL) Schedule 40(UL) BS-1387(LPC) DN(VDS) Torque <br /> inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm ft-lb n-m <br /> VSR-2 2 DN50 2.375 60.3 .065 1.651 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 <br /> VSR-21/2 2.5 - 2.875 73.0 .084 2.134 0.120 3.05 0.203 5.16 - - - - 1.25+.125/-.062 33.0±2.0 <br /> VSR-21/2 - DN65 3.000 76.1 - - 0.142 3.6 0.102 2.6 <br /> VSR-3 3 DN80 3.500 88.9 .083 2.108 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 <br /> VSR-31/2 3.5 - 4.000 101.6 - - 0.120 3.05 0.226 5.74 - - - - 20 27 <br /> VSR-4 4 DN100 4.500 114.3 .084 2.134 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 <br /> 2.00±.125 50.8t2.0 <br /> VSR-5 5 - 5.563 141.3 - - 0.134 3.40 0.258 6.55 - - - - <br /> VSR-6 6 DN150 6.625 168.3 2.921 1 0.134 3.40 1 0.280 7.11 0.197 5.0 0.157 4.0 <br /> VSR-8 8 1 DN200 8.625 219.1 0.148 3.76 1 0.322 1 8.18 1 0.248 6.3 0.177 4.5 <br /> Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br /> 5401146-REV N 10/21 PAGE 2 OF 5 <br />