&NAUTOCALL <br /> TrueAlarm Analog Sensors- Photoelectric and Heat; Standard Bases and Accessories <br /> Sensor bases You can change different TrueAlarm sensor types to meet location <br /> A4098-9792,standard sensor base requirements.You can use this feature to substitute sensors during <br /> building construction.When conditions are temporarily dusty,you can <br /> A4098-9789,sensor base with wired connections install heat sensors without reprogramming the control unit.Although <br /> A2098-9808 remote LED alarm indicator or A4098-9822 relay.The the control unit indicates an incorrect sensor type,the heat sensor <br /> relay is unsupervised and requires separate 24 VDC. operates at a default sensitivity and provides heat detection for building <br /> Supervised relay bases protection at that location. <br /> A4098-9791,four-wire sensor base,use with remote or locally <br /> mounted A2098-9737 relay,requires separate 24 VDC Mounting reference <br /> A4098-9780,two-wire sensor base,use with remote or locally Figure 3:Mounting reference <br /> mounted A4098-9860 relay,no separate power required <br /> You can program supervised relay operation,and manually operate it Electrical Box Requirements:(boxes are by others) <br /> from the control unit Without relay in the box:4"octagonal or 4"square,1-1/2"deep; <br /> Includes wired connections for remote LED alarm indicator or single gang,2"deep <br /> A4098-9822 relay,relay is unsupervised and requires separate 24 With relay in the box:4"octagonal or 4"square,1-1/2"deep, <br /> VDC with 1-1/2"extension ring <br /> Sensor base options 4"(102 mm)Square Box 4"(102 mm)Octagonal Box <br /> A2098-9737,remote or local mount supervised relay Surface mount reference <br /> DPDT contacts for resistive or suppressed loads <br /> power limited rating of 3 A at 28 VDC <br /> non-power limited rating of 3 A at 120 VAC,requires external 24 VDC U <br /> coil power f <br /> A4098-9860,remote or local mount supervised relay 1-1/2"(38 mm) <br /> SPDT dry contacts,power limited rating of 2 A at 30 VDC,resistive. minimum box depth Flush mount reference,mount even with final <br /> Non-power limited rating of 0.5 A at 125 VAC,resistive surface,or with up to 1/4"(6.4 mm)maximum recess <br /> A4098-9822,LED annunciation relay Supervised Relay' <br /> P Relay(mounts <br /> Activates when base LED is on steady,indicating local alarm or (mounts in base electrical box or in base electrical box) <br /> trouble remotely) <br /> DPDT contacts for resistive or suppressed loads,power limited rating <br /> of 2 A at 28 VDC.Non-power limited rating of 1/2 A at 120 VAC, J7 requires external 24 VDC coil power <br /> Relay Size: 2-1/2"X 1-1/2"X 1" <br /> 4098-9832,adapter plate (3.75 in 3)(64 mm X 38 mm X 25.4 mm) <br /> Required for surface or semi-flush mounting to 4 in.square electrical <br /> box and for surface mounting to a 4 in.octagonal box Supervised RelayZ(mounts in base <br /> You can use the 4098-9832 adapter plate for cosmetic retrofitting to electrical box or remotely;2-3/8"X 1-1/4"X 11/32" <br /> an existing 6 3/8 in.diameter base product (1 in 3)(60.4 mm X 31.8 mm X 8.6 mm) <br /> A2098-9808,remote red LED alarm indicator <br /> Mounts on single gang box NOTE:Review total wire count,wire size,and accessories being <br /> wired to determine required box volume. <br /> Figure 2:Remote red LED alarm indicator <br /> ��. 6-3/8"(162 mm) <br /> Adapter Plate,required for <br /> 1/4" mounting to surface mounted boxes <br /> (6.4 mm) and 4"square flush box <br /> ALARM 4-7/8"(124 mm) <br /> 15/16" <br /> (24 mm) 0 <br /> TrueAlarm Bases <br /> Table 1:Product mounting-Model reference <br /> Product Model <br /> Relay A4098-9822 <br /> Description Supervised relay Example 1 A2098-9739 <br /> TrueAlarm sensor bases contain integral addressable electronics that Example 2 A4098-9860 <br /> monitor the status of the detachable photoelectric or heat sensors.The Adapter plate 4098-9832 <br /> sensors transmit digitalized output to the system fire alarm control unit TrueAlarm bases A4098-9780,A4098-9789, <br /> every four seconds. A4098-9791,A4098-9792 <br /> Page 2 AC4098-0019 Rev.33 06/2023 <br />