Laserfiche WebLink
&NAUTOCALL <br /> TrueAlarm Analog Sensors- Photoelectric and Heat; Standard Bases and Accessories <br /> TrueAlarm sensors In a slowly developing fire,the temperature may not increase rapidly <br /> enough to operate the rate-of-rise feature.However,when the <br /> Features temperature reaches the rated fixed temperature setting,it triggers an <br /> alarm. <br /> Sealed against rear air flow entry You can program TrueAlarm heat sensors as a utility device to monitor <br /> Interchangeable mounting for temperature extremes in the range of 32°F to 155°F(0°C to 68°C). <br /> EMI/RFI shielded electronics This feature can provide freeze warnings,or alert you to HVAC system <br /> Heat sensors: problems.Refer to panel specifications for availability. <br /> - Selectable rate-compensated,fixed temperature sensing with or Figure 5: A4098-9733 heat sensor with base <br /> without rate-of-rise operation <br /> Table 2:Rated spacing distance between sensors -7/8"(124 mm) <br /> Fixed Temp. UL and ULC FM Spacing,Either Fixed <br /> Setting Spacing Temperature Setting LED status indicator <br /> 1350F(57.2°C) 60 ft x 60 ft 20 ft x 20 ft(6.1 m)for fixed <br /> 190°F(88°C) (18.3 m) temperature only.RTI=Quick 2 3/8 <br /> 50 ft x 50 ft(15.2 m)for fixed (60 mm) <br /> 155°F(68°C) (1 ft x2.2 m)) ft temperature with either rate-of-rise <br /> selection.RTI=Ultra Fast <br /> Note:190°F(88°C)ratings only apply to the A4098-9734 sensor. <br /> Smoke sensors Figure 6: A4098-9734 high temperature heat sensor with base <br /> Photoelectric technology sensing - -T <br /> 360'smoke entry for optimum response -7/8"(124 mm) <br /> Built-in insect screens <br /> LED status indicator <br /> A4098-9714 photoelectric sensor 2-3/8" <br /> TrueAlarm photoelectric sensors use a stable,pulsed LED light source (60 mm) <br /> and a silicon photodiode receiver to deliver low power smoke sensing. <br /> There are three user-selectable sensitivities for special applications <br /> for each individual sensor:0.2%,0.5%,and 1%for each foot.Standard <br /> sensitivity is 1.25%to 3.1%for each foot.The fire alarm control unit can IF <br /> vary the sensitivity for normal applications between 1.25%and 3.1%for WARNING:In most fires,hazardous levels of smoke and toxic gas <br /> each foot. can build up before a heat detection device would initiate an alarm.In <br /> Note:Fixed sensitivity settings higher than 1.0%for each foot are not cases where Life Safety is a factor,the use of smoke detection is highly <br /> UL268 7th Edition compliant. recommended. <br /> The sensor head design provides 360'smoke entry for response to Application reference <br /> smoke from any direction. Due to its photoelectric operation,air velocity Only choose sensor locations after careful consideration of the physical <br /> is not normally a factor,except for impact on area smoke flow. layout and contents of the area that you want to protect.Refer to NFPA <br /> Figure 4: A4098-9714 photoelectric sensor with base 72,the National Fire Alarm and Signaling Code.On smooth ceilings,you <br /> can use a smoke sensor spacing of 30 ft(9.1 m)as a guide. <br /> -7/8"(124 mm) For detailed application information including sensitivity selection,refer <br /> II'--LED status indicator to A4098 Detectors,Sensors,and Bases Application Manual(574-709AQ. <br /> 2-1/8" <br /> (54 mm) <br /> A4098-9733 and A4098-9734 heat sensors <br /> TrueAlarm heat sensors are self-restoring and provide rate- <br /> compensated,fixed temperature sensing with or without rate-of-rise <br /> temperature sensing.The sensor measures the local temperature for <br /> analysis at the fire alarm control unit. <br /> You can select rate-of-rise temperature detection at the control unit for <br /> either 15°F or 20°F,(8.3°C or 11.1°C)for each minute.Fixed temperature <br /> sensing is independent of rate-of-rise sensing and you can program it <br /> to operate at 135°F or 155°F(57.2°C or 68°C).The A4098-9734 sensor <br /> provides an additional 190°F(88°C)set point. <br /> Page 3 AC4098-0019 Rev.33 06/2023 <br />