My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2725 32ND AVE NE 2024 PROPANE NORTHWEST Plans 2025-08-20
>
Address Records
>
32ND AVE NE
>
2725
>
PROPANE NORTHWEST
>
Plans
>
2725 32ND AVE NE 2024 PROPANE NORTHWEST Plans 2025-08-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/20/2025 11:39:44 AM
Creation date
8/20/2025 11:38:22 AM
Metadata
Fields
Template:
Address Document
Street Name
32ND AVE NE
Street Number
2725
Tenant Name
PROPANE NORTHWEST
Permit
TANK2405-002
Year
2024
Notes
installing a 30000 gallon propane storage tank
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Form 9.1 <br /> Analysis Summary on Product Control and Local Conditions of Hazard <br /> A B C D E <br /> Number of <br /> Item Reference <br /> # Chapter Title Section&Title Form# "No" <br /> checked <br /> 5.1 Product Control in 5.1 or 5.2 0 <br /> Containers <br /> 1 Product Control Measures in 5.4 0 <br /> 5. <br /> Containers&Transfer Piping 5.2 Product Control in <br /> Transfer Piping 5.5 0 <br /> 0 <br /> 5.7 0 <br /> 6.1 Physical Protection 6.1 0 <br /> Measures <br /> 6.2 Ignition Source 6.2 0 <br /> Control <br /> 6.3.1 Separation distances; <br /> 2 Analysis of Local Conditions Container and 6.3 0 <br /> of Hazard outside exposures <br /> 6.3.2 Separation distances; <br /> Transfer points and 6.4 0 <br /> outside exposures <br /> 6.4 Special Protection 6.5 0 <br /> Measures 6.6 0 <br /> § The number of"No" for Forms from Chapter 5 is the difference between the required number of appurtenances <br /> according to NFPA 58-2020, and a lesser number found to be actually installed on the container or the transfer <br /> piping. <br /> If, in any row of column E ("No") of Form 9.1, the entry number is greater than <br /> zero, the proposed LP-Gas facility is not in compliance with the requirements of <br /> NFPA 58-2020 for product control appurtenances or other safety measures. The <br /> design of the proposed facility must be modified to conform to the code <br /> requirements. In addition, the following items should be noted. <br /> • If there are any "No" checks in Form 6.3, then the separation distance <br /> requirements for containers are not satisfied. An option that may be <br /> considered is the reduction in separation distance to 10 feet for underground <br /> and mounded containers by providing "Redundant and Fail-Safe Product <br /> Control Measures." In this case, complete Form 9.4 below to ensure that each <br /> requirement of "Redundant and Fail-Safe Product Control Measures" is <br /> provided. <br /> • If there are any "No" checks in Form 6.4, then the separation distance <br /> requirements for transfer points are not satisfied. In this case, relocate the <br /> transfer points so that the separation distances conform to the code <br /> requirements or provide the Low Emission Transfer Equipment. Complete <br /> Form 9.5 below and ensure that all requirements for Low Emission Transfer <br /> Equipment are fulfilled. <br /> A - 24 <br />
The URL can be used to link to this page
Your browser does not support the video tag.