2725 32ND AVE NE 2024 PROPANE NORTHWEST Plans 2025-08-20
>
Address Records
>
32ND AVE NE
>
2725
>
PROPANE NORTHWEST
>
Plans
>
2725 32ND AVE NE 2024 PROPANE NORTHWEST Plans 2025-08-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/20/2025 11:39:44 AM
Creation date
8/20/2025 11:38:22 AM
Metadata
Fields
Template:
Address Document
Street Name
32ND AVE NE
Street Number
2725
Tenant Name
PROPANE NORTHWEST
Permit
TANK2405-002
Year
2024
Notes
installing a 30000 gallon propane storage tank
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Form 9.2 <br /> Analysis Summary on Exposure from and to the LP-Gas Facility <br /> A B C D E <br /> Number of <br /> Item Reference <br /> # Chapter Title Section&Title Form# "Yes" <br /> checked <br /> 7.1 Exposure to off-site <br /> properties and persons from 7.1 p <br /> 1 Exposure to and from Other in-plant propane releases <br /> Properties <br /> 7.2 Exposure to propane facility 7.2 p <br /> from external events <br /> If the entry number in column E ("Yes"), Form 9.2 corresponding to Form <br /> 7.1 is greater than zero, consider one or more of the following design <br /> alternatives: <br /> 1. Consider moving the container or the transfer point to a different <br /> location, if possible and space exists, so that the property or the person <br /> is beyond the hazard distance. <br /> 2. Provide "Redundant and Fail-safe Product Control Measures." <br /> Complete Form 9.4 to ensure compliance. <br /> 3. Institute other technical measures such as installing gas and flame <br /> detectors (connected to facility shutdown systems), sounding alarm <br /> outside facility premises, etc. <br /> 4. Institute administrative controls such as additional training for <br /> personnel, more frequent inspections of hoses and transfer piping, etc. <br /> If the entry number in column E ("Yes"), Form 9.2 corresponding to Form <br /> 7.2 is greater than zero, consider one or more of the following design <br /> alternatives: <br /> 1. Implement procedures to monitor neighboring activity. <br /> 2. Install means in the adjacent plant to shut down the LP-Gas plant in case <br /> of an emergency in that plant. <br /> A - 25 <br />