2725 32ND AVE NE 2024 PROPANE NORTHWEST Plans 2025-08-20
>
Address Records
>
32ND AVE NE
>
2725
>
PROPANE NORTHWEST
>
Plans
>
2725 32ND AVE NE 2024 PROPANE NORTHWEST Plans 2025-08-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/20/2025 11:39:44 AM
Creation date
8/20/2025 11:38:22 AM
Metadata
Fields
Template:
Address Document
Street Name
32ND AVE NE
Street Number
2725
Tenant Name
PROPANE NORTHWEST
Permit
TANK2405-002
Year
2024
Notes
installing a 30000 gallon propane storage tank
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Form 9.3 <br /> Analysis Summary on Fire Department Evaluations <br /> A B C D E F <br /> Number Number of <br /> "zeros" "Yes" <br /> Item Reference entered in checked in <br /> # Chapter Title Section&Title Form# Column C, Column C <br /> Lines 6 of Form 8.4 <br /> through 8 of <br /> Form 8.1 <br /> 1 Fire department 8.1 Data on the Fire 8.1 <br /> capability,adequacy Department <br /> of water supply and 8.2 Fire response water <br /> 2 Emergency Planning needs and availability 8.4 1 <br /> If the entry number in row 1, Column E of Form 9.3 is greater than zero, <br /> consider one or more of the following design alternatives: <br /> 1. Discuss with the local Fire Department the needs of the LP-Gas facility <br /> and the evaluation results on the capability and training inadequacies of <br /> the Department. <br /> 2. Consider developing a cadre of personnel within the LP-Gas facility to <br /> respond to emergencies. <br /> 3. Institute container special protection system based on active protection <br /> approaches or passive approaches. Complete Form 9.6 and Form 9.7 <br /> below. <br /> If the entry number in row 2, Column F of Form 9.3 is equal to zero, consider <br /> one or more of the following design alternatives: <br /> 1. Provide special protection (other than water spray or monitor systems) to <br /> containers, satisfying the requirements of section 6.29.5 of NFPA 58, <br /> 2020 edition. Complete Form 9.6 to ensure compliance. <br /> 2. Consider implementing the various options indicated in Table 9.1. <br /> A - 26 <br />