BERC2 CLIP � 8" 12 GA. HANGER 8" � <br /> \ MAX. WIRE 4'-0" o.c. MAX. / BERC2 CLIP <br /> \ (SEE DETAIL 1) <br /> POP RIVET MAIN RUNNER i <br /> \ OR CROSS TEE WALL <br /> �n WALL \ <br /> CROSS TEE CROSS TEE ANGLE ACOUSTICAL / <br /> \ BOARD / WALL <br /> WALL 1/8" POP RIVET (NO POP RIVETS) ANGLE <br /> PROVIDE 3/4" SPACE AT WALL <br /> MEMBER AT OPPOSING WALL <br /> WALL ANGLE (ATTACHED WALLS) (UNATTACHED WALLS) <br /> #8 x 1/2" ROUND WASHER HEAD TEK <br /> WALL ANGLE SCREW (SELF— TAPPING) NOTE: <br /> NOTE: SCREW IS NOT TIGHTENED DOWN ATTACHED WALL HANGER AND PERIMETER WIRES MUST BE PLUMB WITHIN 1: 6 UNLESS <br /> AGAINST BERC2 CLIP (TWO ADJACENT WALLS) COUNTER SLOPING WIRES ARE PROVIDED <br /> LATERAL—FORCE BRACING: <br /> UNATTACHED WALL SEISMIC BERC2 CLIP 9 IS THE USE OF VERTICAL STRUTS AND SPLAY WIRES. <br /> (TWO ADJACENT WALLS) —FACTORY INSTALLED AT TWO ADJACENT WALLS. CEILING AREAS OF 1000 SQ.FT. OR LESS SHALL BE EXEMPT FROM <br /> —SCREW TIGHTENED FOR SHIPPING IN ROOMS WHERE LATERAL—FORCE BRACING REQUIREMENTS. <br /> CEILING CROSSES MOD LINE, LOOSEN SCREW ON SITE CEILINGS WITH INTERSTITIAL SPACE LESS THAN 12" TO FRAMING <br /> BY SET UP CREW ARE NOT REQUIRED TO HAVE LATERAL—FORCE BRACING. <br /> —NOT REQUIRED FOR CEILINGS LESS THAN OR EQUAL SEISMIC SEPARATION JOINTS: <br /> TO 144 SF AND SURROUNDED BY WALLS CONNECTED TO ALL CONTINUOUS CEILING AREAS EXCEEDING 2500 SQ.FT. SHALL <br /> THE STRUCTURE ABOVE. HAVE A SEISMIC SEPARATION JOINT. <br /> —SOURCES: ASCE 7-16 SECTION 13.5.6 EXCEPTION 1, <br /> ASTM E580 SECTION 1.4 <br /> SEISMIC ATTACHMENT AT WALLS 2 STANDARD T-BAR DETAIL <br /> N.T.S. (ARMSTRONG SEISMIC 'Rx' SUSPENSION SYSTEM (ESR 1308)] N.T.S. <br /> O SEISMIC BERC CLIP O <br /> SUSPENDED T—BAR —FACTORY INSTALLED <br /> CEILING GRID AT TWO ADJACENT WALLS 2 x 2 SUPPLY <br /> SEE DETAIL (2/A-5) SEE DETAIL (1/A-5) AIR DIFFUSER <br /> 0 1 0 7rz-71 0 <br /> LL ' I <br /> O <br /> WALL MOUNTED <br /> EXHAUST FAN <br /> TYP. OF 3 <br /> REFLECTED CEILING PLAN_ <br /> SCALE: 1/4" = 1'-0" <br /> CUSTOMER APPROVAL <br /> ❑ APPROVED <br /> STATEMENT OF SPECIAL INSPECTIONS ❑ APPROVED EXCEPT AS NOTED <br /> The materials, systems, components, and work required to have special REVISE AS NOTED AND RESUBMIT <br /> inspections are listed below. Inspections will be completed by the APPROVED By Date <br /> engineer of record. <br /> Special inspection for suspended ceiling system: PRELIMINARY <br /> Periodic inspection of the suspended ceiling system to verify that it <br /> complies with ESR-1308. NOT FOR CONSTRUCTION <br /> 12-7-21 PRELIM REVIEW- DG LDG COPYRIGHT2021, BLAZER INDUSTRIES, INC. ■ MOBILE ADARR for. Approved forConst: Job No: 20080 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF BLAZER INDUSTRIES, INC.AND SHALL ■■ gi <br /> �`j/�� 10 x 46 Port of Everett Norton Expansion File Copy: <br /> NOT BE REPRODUCED, USED, OR DISCLOSED � <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE �� NDU INC. Drawn By: LDG <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. P.O.BOxa89 we,O*R z 325- 48 WA Pacific Mobile Everett WA A=5 <br /> ■■ 945 Olney St. ■ Aumsville,OR 97325-0489 � Issue Date: 12-7-21 <br />