My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2600 FEDERAL AVE PORT OF EVERETT 2026-01-15
>
Address Records
>
FEDERAL AVE
>
2600
>
PORT OF EVERETT
>
2600 FEDERAL AVE PORT OF EVERETT 2026-01-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2026 9:00:57 AM
Creation date
8/20/2025 1:20:17 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
2600
Tenant Name
PORT OF EVERETT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
527
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
g A <br /> PACKAGE *SPVU * HIGH EFFICIENCY WALL MOUNT HEAT PUMP SCHEDULE <br /> SINGLE POINT <br /> DID FAN SENSIBLE HEATING HEAT CONNECTION <br /> BLOWER BLOWER EFFICIENCY VENTIL. COOLING COOLING CAPACITY HEATING HEAT STRIPS <br /> UNIT BARD UNIT UNIT MOTOR AIRFLOW SPEED BLOWER GRADE VENTIL. (FA) FILTER OUTDOOR ENTERING ENTERING CAPACITY CAPACITY 47degs COP UNIT UNIT STRIPS OUTPUT MCA MOCP UNIT <br /> TAG UNIT MODEL NUMBER SIZE QTY TYPE CFM SETTING HP (FEG) DEVICE CFM TYPE EER (DB) TEMP (DB) TEMP (WB) TEMP BTUH BTUH BTUH 47degs HERTZ VOLTS PHASE KW BTUH AMPS AMPS WGT ADDITIONAL NOTES <br /> HP-1 W48HC-A15ZP4XXR 4.0 1 ECM 1686 MED 3/4 ---- ECON ---- MERV-8 11 95 80 67 48,330 37,679 41,378 3.3 60 240 1 15 51,195 87 90 505 1,2,3,4,5,6,7,8,9,10, <br /> ADDITIONAL NOTES: <br /> (DOO <br /> 1 - CAPACITY LISTED ABOVE ARE IN ACCORDANCE WITH ANS/ARI STANDARD 390-2003 FOR SPVU (SINGLE PACKAGE VERTICAL UNITS) Sequence of operation: <br /> 2 - COMPLIES WITH EFFICIENCY REQUIREMENTS OF ANSI/ASHRAE/IESNA 90.1-2016 1- Upon a Cooling call from the room thermostat the unit will be in mechanical cooling <br /> 3 - BARD THERMOSTAT (8403-060), 7-DAY PROGRAMMABLE mode. <br /> 4 - BARD INDOOR REMOTE SENSOR. (8403-062) 2- Upon a heating call from the room thermostat the unit will be in mechanical heating, <br /> 5 - DELETED 2nd stage heat strips will come on if the room temperature drops below <br /> 6 - HEAT STRIPS KIT WITH CIRCUIT BREAKER its setpoint and during defrost. <br /> 7 - DELETED 3- DELETED <br /> 8 - 2" PLEATED FILTER, MERV-8 4- These modes with keep repeating and required by the thermostat. <br /> 9 - UNIT COLOR IS *BUCKEYE GRAY* 5- If this unit is equipped with a exterior door shut down kit the unit mechanical system <br /> PLENUM VARIFICATION 10 - OUTDOOR THERMOSTAT SET AT 40DEG'S & LAC CONTROL (R) CONTROL will shut down after the exterior has been open for minutes. The ventilation <br /> portion will keep operating. Once the door closes the unitit will restart if there is still <br /> 11 - DELETED <br /> a call from the thermostat. <br /> 12 - (BSDTIMER) KIT - PROVIDES A MEANS ON SHUTTING DOWN OF THE MECHANICAL COOLING AND HEATING SYSTEM, VENTILATION CONTINUES TO OPERATE, VIA EXTERIOR DOOR SWITCH (OPTIONAL) <br /> SCALE: 1/2" = 1'-0" <br /> ** M.C. TO REFER TO INSTALLATION INSTRUCTIONS FOR START UP AND EQUIPMENT SET <br /> ** M.C. TO CHECK SITE VOLTAGE AND SET CORRECT TAP ON TRANSFORMER <br /> ** M.C. TO SET AND PROGRAM THERMOSTAT PER CUSTOMERS REQUIREMENTS <br /> ** M.C. TO SET AND CHECK ECONOMIZER AND VENTILATION PRE PROJECT REQUIREMENTS <br /> 0 0 <br /> MECHANICAL NOTES: RELIEF VENT WITH <br /> BACKDRAFT DAMPER <br /> WA - 2018 IMC WAC AND 2018 WSEC TYP. OF 4 <br /> 1. VENTILATION PROVIDED VIA NATURAL VENTILATION IN ACCORDANCE WITH IMC SECTION 402 IN O <br /> LIEU OF DOAS REQUIREMENTS. [WSEC SECTION C 403.3.5 EXCEPTION 11 4 TON 15 kW <br /> 2. MECHANICAL EQUIPMENT INSTALLATION IN OR ON THIS BUILDING SHALL BE IN ACCORDANCE WITH WALL HUNG <br /> THE REQUIREMENTS OF IMC WAC CHAPTER 6 UNLESS OTHERWISE EXEMPTED. HEAT PUMP <br /> 3. DUCT MATERIAL IS 26 GA. GALVANIZED WITH 2.2" FSK INSULATION. DUCTWORK SHALL BE <br /> SUPPORTED. [IMC WAC SECTION 603] 12 <br /> 4. ROUND FLEX DUCT SHALL BE UL LISTED CLASS 1, STANDARD 181 - FACTORY MADE AIR TO <br /> 2 <br /> DUCTSAND AIR CONNECTORS.THE MINIMUM THERMAL PERFORMANCE SHALL BE AT R-6, AND <br /> MEASURED IN ACCORDANCE WITH ATSM C 518 OR ATSM C 177 AT 75DEG F MEAN 12 <br /> TEMPERATURE. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION <br /> INSTRUCTIONS. <br /> 5. MATERIAL IN DUCTS SHALL HAVE A FLAME SPREAD INDEX OF LESS THAN 25, SMOKE PLENUM #PWS134 <br /> DEVELOPMENT OF 50. [IMC SECTION 602] <br /> 6. LOW PRESSURE DUCT SYSTEMS SHALL HAVE LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS O <br /> AND CONNECTIONS OF SUPPLY AND RETURN DUCTS AND PLENUMS SECURELY FASTENED AND <br /> SEALED WITH WELDS, GASKETS, MASTICS (ADHESIVES), MASTIC-PLUS EMBEDDED-FABRIC WALL MOUNTED <br /> SYSTEMS OR APPROVED TAPES INSTALLED IN ACCORDANCE WITH IMC WAC SECTION 603.9. WALL MOUNTED <br /> 7. DUCT INSULATION SHALL COMPLY WITH IMC WAC SEC 604. EXHAUST FAN EXHAUST FAN <br /> 8. WHEN ISOLATION SLEEVES ARE USED AT LINE CONNECTIONS TO PLENUMS, THEY SHALL COMPLY <br /> TYP. OF 3 TYP. OF 3 <br /> WITH IMC WAC CHAPTER 6. MECHANICAL PLAN <br /> 9. IF DIFFUSERS HAVE NO MANUAL DAMPERS, USE FLOW CONTROL AT WYES. TYPICAL AS NOTED ON TYPICAL DOOR SWITCH WITH <br /> PLAN. TIME DELAY WIRING FOR HEAT PUMPS <br /> 10. MINIMUM OUTSIDE AIR VENTILATION PER IMC WAC TABLE 403.3.1.1. THIS DRAWING IS SHOWN WITH A JUMPER WIRE SCALE: 1/4" = V-0" <br /> INSTALLED ON TERMINALS#1 TO#2"DOOR <br /> 11. OUTSIDE AIR DAMPERS SHALL COMPLY WITH WSEC, SECTION C403.7.8. SWITCH JUMPER" WIRE.REMOVE JUMPER WHEN <br /> DOOR SWITCH IS INSTALLED,WIRED AS SHOWN. <br /> 12. ALL NEW SYSTEMS REQUIRE ECONOMIZERS UNLESS EXEMPTED BY EXCEPTIONS. [WSEC SECTION <br /> 403.5] O O <br /> 13. DOOR SWITCH CONTROLS SHALL BE INSTALLED IN ACCORDANCE WITH WSEC 403.4.1.6 AT ALL F---------�� 1� <br /> DOORS THAT OPEN TO THE OUTDOORS. ------ R�--- RT MECHANICAL SYMBOLS <br /> �� <br /> 14. MECHANICAL DRAWINGS SHOW DUCTWORK SIZES TO BE CLEAR INSIDE DIMENSION. I 2 W2El ®G <br /> 15. ELECTRICIAN MUST VERIFY ALL ELECTRICAL REQUIREMENTS AND LOCATIONS. 3® SYMBOL DESCRIPTION <br /> 16. CONTRACTOR SHALL ARRANGE ALL HVAC UNITS AND ASSOCIATED ITEMS FOR ACCESS W3® ®C <br /> 14® E® Y ®® 2'x2 SUPPLY AIR DIFFUSER <br /> CLEARANCES. I I <br /> 17. THERMOSTAT SCHEDULING TO BE PERFORMED ON SITE BY OTHERS. <br /> I I e ED <br /> L ® ®Y1 ______ EXHAUST FAN DUCT/RELIEF AIR GRILLE DUCT <br /> 18. ALL HVAC EQUIPMENT LEAVES FACTORY WIRED FOR 240 VOLT OPERATION. 6ED <br /> 19. THE ACCEPTABLE OPERATING RANGE FOR THE 240V & 208V TAPS ARE: 70 DH® B EXHAUST FAN WITH HOOD <br /> TAP RANGE ® 01 ® <br /> FIELD 8 ®W1 <br /> 240 253 -216 INSTALLED O O <br /> 14"x14" RELIEF VENT WITH BACKDRAFT DAMPER <br /> WIRES ADD NEW UNIT LOW VOLTAGE <br /> 208 220-187 TERMINAL TERMINAL BLOCK <br /> BARD -X - SUPPLY DUCT w/DIAMETER INDICATOR <br /> 20. SITE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR MAKING SURE THE RIGHT TAP IS BLOCK <br /> CONNECTED FOR THE APPLIED SITE VOLTAGE. 8607-021 <br /> L--- O THERMOSTAT <br /> 21. AIR FILTERS IN HVAC UNITS OR SYSTEMS ARE TO BE CHANGED EVERY 30 DAYS BY OTHERS ON �DOOR SWITCH(FIELD SUPPLIED) <br /> SWITCH IS OPEN WHEN DOOR <br /> SITE. IS IN THE OPEN POSITION <br /> 22. REGISTER AIR FLOW TEST AND BALANCE OF HVAC SYSTEM TO BE PROVIDED AND PERFORMED BY SWITCH IS CLOSED WHEN DOOR RS REMOTE SENSOR <br /> OTHERS ON SITE WHEN REQUIRED. L -T IS IN THE CLOSED POSITION <br /> 23. HVAC SITE CONTRACTOR IS RESPONSIBLE FOR BALANCING THE SYSTEM. BALANCING SHALL BE IN THIS KIT WILL COMPLY WITH WSECC403-4.1.6 <br /> ACCORDANCE WITH IMC WAC 403.3.1.5. CUSTOMER APPROVAL <br /> ❑ APPROVED <br /> ❑ APPROVED EXCEPT AS NOTED PRELIMINARY <br /> ❑ REVISE AS NOTED AND RESUBMIT <br /> APPROVED By Date NOT FOR CONSTRUCTION <br /> 12-7-21 PRELIM REVIEW- DG LDG COPYRIGHT2021, BLAZER INDUSTRIES, INC. ■ MOBILE ADARR for. Approved forConst: Job No: 20080 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY ri <br /> OF BLAZER INDUSTRIES, INC.AND SHALL ■■ �`j/�� 10 x 46 Port of Everett Norton ExpansionFile Copy: <br /> NOT BE REPRODUCED, USED, OR DISCLOSEDTO OTHERS EXCEPT AS AUTHORIZED BY THE 0�� DUSTRIES,INC. Drawn By: LDG <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. P.O.BOX489 www.blazerind.com WA Pacific Mobile Everett WA Issue Date: 12-7-21 M 1 <br /> ■■ 945 Olney St. ■ Aumsville,OR 97325-0489 <br />
The URL can be used to link to this page
Your browser does not support the video tag.