Laserfiche WebLink
TFP344 <br /> Page 4of4 <br /> P/N 50 - XXX - X - XXX <br /> a. ForTY5131 <br /> SIN SPRINKLER TEMPERATURE andTY5231 <br /> FINISH RATING sprinklers <br /> only. <br /> 500 11.2K UPRIGHT(3/4 in. NPT) TY5131 1 NATURAL BRASS 155 155°F(68°C) b. For retrofit <br /> applications <br /> 502 11.2K PENDENT(3/4 in.NPT) TY5231 9 CHROME PLATED® 200 200°F(93°C) only. <br /> 503 11.2K UPRIGHT(1/2 in.NPT) TY5831® 286 286°F(141°C)® <br /> TABLE D <br /> SERIES ELO-231FRB UPRIGHT&PENDENT 11.2K SPRINKLERS, QUICK RESPONSE <br /> PART NUMBER SELECTION <br /> "FITTING SIDE" The Series ELO-231FRB Upright and Care must be exercised to avoid <br /> TOWARDS SPRINKLER Pendent Sprinklers must be installed damage to the sprinklers before, <br /> FITTING in accordance with the following during, and after installation. Sprin- <br /> instructions: klers damaged by dropping, striking, <br /> Step 1. Upright sprinklers are to wrench twist/slippage,or the like, must <br /> �\ be installed in the upright position, be replaced.Also,replace any sprinkler <br /> pendent sprinklers are to be installed that has a cracked bulb or that has lost <br /> / in the pendent position. liquid from its bulb. For additional infor- <br /> WRENCH mation, refer to the Installation section. <br /> / RECESS Step 2. With pipe thread sealant The owner is responsible for the <br /> (END 'A") applied to the pipe threads, hand- inspection,testing,and maintenance of <br /> tighten the sprinkler into the sprinkler their fire protection system and devices <br /> FIGURE 2 fitting. in compliance with this document, as <br /> W-TYPE3 Step 3. Tighten the sprinkler into well as with the applicable standards <br /> SPRINKLER WRENCH the sprinkler fitting using only the of the National Fire Protection Asso- <br /> W-Type 3 Sprinkler Wrench (Ref. ciation (e.g., NFPA 25), in addition to <br /> Figure 2). With reference to Figure 1, the standards of any other authorities <br /> Installation the W-Type 3 Sprinkler Wrench is to be having jurisdiction.Contact the install- <br /> TYCO Series ELO-231 FRB 11.2K applied to the wrench flats. ing contractor or product manufacturer <br /> Quick Response, Standard Coverage, with any questions. <br /> Upright and Pendent Sprinklers must Care and It is recommended that automatic <br /> be installed in accordance with this Maintenance sprinkler systems be inspected,tested, <br /> section. and maintained by a qualified Inspec- <br /> General Instructions TYCO Series ELO-231 FRB 11.2K Quick tion Service in accordance with local <br /> Response,Standard Coverage,UprightEEM requirements and/or national codes. <br /> and Pendent Sprinklers must be main- <br /> Do not install any bulb-type sprinkler tained and serviced in accordance with Li r"ited <br /> if the bulb is cracked or there is a loss this section. Warranty <br /> of liquid from the bulb. With the sprin- Before closing a fire protection system <br /> kler held horizontally,a small air bubble control valve for maintenance work on For warranty terms and conditions,visit <br /> should be present. The diameter of the the fire protection system that it con- www.tyco-fire.com. <br /> air bubble is approximately 1116 in. trols, permission to shut down the <br /> (1,6 mm)for the 155°F(68°C)to 3132 in.(2,4mm)forthe286°F(14VQtempera- affected fire protection system must Ordering <br /> ture ratings. be obtained from the proper authorities <br /> and all personnel who may be affected procedure <br /> A leak tight 1/2 in. NPT sprinkler joint by this action must be notified. <br /> should be obtained by applying a Sprinklers that are found to be leaking Contact your local distributor for avail- <br /> minimum-to-maximum torque of 7 to or exhibiting visible signs of corrosion ability.When placing an order, indicate <br /> 14 lb-ft (9,5 to 19,0 N•m). A leak-tight must be replaced. the full product name and Part Number <br /> 3/4 in. NPT sprinkler joint should be (P/N). <br /> obtained by applying a minimum-to- Automatic sprinklers must never be <br /> maximum torque of 10 to 20 lb-ft(13,4 painted, plated, coated or other- Sprinkler <br /> to 26,8 N•m). Higher levels of torque wise altered after leaving the factory. Specify: Series ELO-231FRB 11.2K <br /> can distort the sprinkler inlet with con- Modified sprinklers must be replaced. Quick Response (specify Pendent <br /> sequent leakage or impairment of the Sprinklers that have been exposed to or Upright) Sprinkler, (specify SIN), <br /> sprinkler. corrosive products of combustion, but (specify) temperature rating, (specify) <br /> Do not attempt to make up for insuf- have not operated,should be replaced finish, P/N (specify from Table D) <br /> ficient adjustment in the escutcheon if they cannot be completely cleaned Sprinkler Wrench <br /> plate by under- or over-tightening the by wiping the sprinkler with a cloth or Specify: W-Type 3 Sprinkler Wrench, <br /> sprinkler. Readjust the position of the by brushing it with a soft bristle brush. P/N 56-895-1-001 <br /> sprinkler fitting to suit. <br /> 1400 Pennbrook Parkway,Lansdale,PA 19446 1 Telephone+1-215-362-0700 m 2022 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson <br /> 1 nson ORO <br /> NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Controls <br /> TEFLON Is a trademark of The Ch.n o Company FC,LLC <br />