My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1605 SE EVERETT MALL WAY WALMART 2025-09-10
>
Address Records
>
SE EVERETT MALL WAY
>
1605
>
WALMART
>
1605 SE EVERETT MALL WAY WALMART 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 2:48:40 PM
Creation date
8/21/2025 12:35:01 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1605
Tenant Name
WALMART
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
273
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TFP344 <br /> Page 4of4 <br /> P/N 50 - XXX - X - XXX <br /> a. ForTY5131 <br /> SIN SPRINKLER TEMPERATURE andTY5231 <br /> FINISH RATING sprinklers <br /> only. <br /> 500 11.2K UPRIGHT(3/4 in. NPT) TY5131 1 NATURAL BRASS 155 155°F(68°C) b. For retrofit <br /> applications <br /> 502 11.2K PENDENT(3/4 in.NPT) TY5231 9 CHROME PLATED® 200 200°F(93°C) only. <br /> 503 11.2K UPRIGHT(1/2 in.NPT) TY5831® 286 286°F(141°C)® <br /> TABLE D <br /> SERIES ELO-231FRB UPRIGHT&PENDENT 11.2K SPRINKLERS, QUICK RESPONSE <br /> PART NUMBER SELECTION <br /> "FITTING SIDE" The Series ELO-231FRB Upright and Care must be exercised to avoid <br /> TOWARDS SPRINKLER Pendent Sprinklers must be installed damage to the sprinklers before, <br /> FITTING in accordance with the following during, and after installation. Sprin- <br /> instructions: klers damaged by dropping, striking, <br /> Step 1. Upright sprinklers are to wrench twist/slippage,or the like, must <br /> �\ be installed in the upright position, be replaced.Also,replace any sprinkler <br /> pendent sprinklers are to be installed that has a cracked bulb or that has lost <br /> / in the pendent position. liquid from its bulb. For additional infor- <br /> WRENCH mation, refer to the Installation section. <br /> / RECESS Step 2. With pipe thread sealant The owner is responsible for the <br /> (END 'A") applied to the pipe threads, hand- inspection,testing,and maintenance of <br /> tighten the sprinkler into the sprinkler their fire protection system and devices <br /> FIGURE 2 fitting. in compliance with this document, as <br /> W-TYPE3 Step 3. Tighten the sprinkler into well as with the applicable standards <br /> SPRINKLER WRENCH the sprinkler fitting using only the of the National Fire Protection Asso- <br /> W-Type 3 Sprinkler Wrench (Ref. ciation (e.g., NFPA 25), in addition to <br /> Figure 2). With reference to Figure 1, the standards of any other authorities <br /> Installation the W-Type 3 Sprinkler Wrench is to be having jurisdiction.Contact the install- <br /> TYCO Series ELO-231 FRB 11.2K applied to the wrench flats. ing contractor or product manufacturer <br /> Quick Response, Standard Coverage, with any questions. <br /> Upright and Pendent Sprinklers must Care and It is recommended that automatic <br /> be installed in accordance with this Maintenance sprinkler systems be inspected,tested, <br /> section. and maintained by a qualified Inspec- <br /> General Instructions TYCO Series ELO-231 FRB 11.2K Quick tion Service in accordance with local <br /> Response,Standard Coverage,UprightEEM requirements and/or national codes. <br /> and Pendent Sprinklers must be main- <br /> Do not install any bulb-type sprinkler tained and serviced in accordance with Li r"ited <br /> if the bulb is cracked or there is a loss this section. Warranty <br /> of liquid from the bulb. With the sprin- Before closing a fire protection system <br /> kler held horizontally,a small air bubble control valve for maintenance work on For warranty terms and conditions,visit <br /> should be present. The diameter of the the fire protection system that it con- www.tyco-fire.com. <br /> air bubble is approximately 1116 in. trols, permission to shut down the <br /> (1,6 mm)for the 155°F(68°C)to 3132 in.(2,4mm)forthe286°F(14VQtempera- affected fire protection system must Ordering <br /> ture ratings. be obtained from the proper authorities <br /> and all personnel who may be affected procedure <br /> A leak tight 1/2 in. NPT sprinkler joint by this action must be notified. <br /> should be obtained by applying a Sprinklers that are found to be leaking Contact your local distributor for avail- <br /> minimum-to-maximum torque of 7 to or exhibiting visible signs of corrosion ability.When placing an order, indicate <br /> 14 lb-ft (9,5 to 19,0 N•m). A leak-tight must be replaced. the full product name and Part Number <br /> 3/4 in. NPT sprinkler joint should be (P/N). <br /> obtained by applying a minimum-to- Automatic sprinklers must never be <br /> maximum torque of 10 to 20 lb-ft(13,4 painted, plated, coated or other- Sprinkler <br /> to 26,8 N•m). Higher levels of torque wise altered after leaving the factory. Specify: Series ELO-231FRB 11.2K <br /> can distort the sprinkler inlet with con- Modified sprinklers must be replaced. Quick Response (specify Pendent <br /> sequent leakage or impairment of the Sprinklers that have been exposed to or Upright) Sprinkler, (specify SIN), <br /> sprinkler. corrosive products of combustion, but (specify) temperature rating, (specify) <br /> Do not attempt to make up for insuf- have not operated,should be replaced finish, P/N (specify from Table D) <br /> ficient adjustment in the escutcheon if they cannot be completely cleaned Sprinkler Wrench <br /> plate by under- or over-tightening the by wiping the sprinkler with a cloth or Specify: W-Type 3 Sprinkler Wrench, <br /> sprinkler. Readjust the position of the by brushing it with a soft bristle brush. P/N 56-895-1-001 <br /> sprinkler fitting to suit. <br /> 1400 Pennbrook Parkway,Lansdale,PA 19446 1 Telephone+1-215-362-0700 m 2022 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson <br /> 1 nson ORO <br /> NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Controls <br /> TEFLON Is a trademark of The Ch.n o Company FC,LLC <br />
The URL can be used to link to this page
Your browser does not support the video tag.