Laserfiche WebLink
CO® Worldwide www.tyco-fire.com <br /> Contacts <br /> Series TY.FRB, 5.6 K-factor <br /> Upright, Pendent, and Recessed Pendent Sprinklers <br /> Quick Response, Standard Coverage <br /> General FIVITIM _ __=_-_ _ - <br /> The TYCO Series TY-FRB Sprinklers T I <br /> Description described herein must be installed <br /> and maintained in compliance with <br /> The TYCO Series TY-FRB,5.6 K-factor, this document, as well as with the ' <br /> Upright (TY313) and Pendent (TY323) applicable standards of the National <br /> Sprinklers described In this data sheet Fire Protection Association, in addition ' <br /> are quick response,standard coverage, to the standards of any other authori- <br /> decorative 3 mm glass bulb-type spray ties having jurisdiction. Failure to do so <br /> sprinklers designed for use in light or may impair the performance of these <br /> ordinary hazard,commercial occupan- devices. <br /> cies such as banks, hotels, and shop- The owner is responsible for main- �-� .-t = <br /> ping malls. taining their fire protection system <br /> The recessed version of the Series and devices in proper operating con- <br /> TY-FRB Pendent Sprinkler, where dition. Contact the installing contrac- <br /> applicable, is intended for use in areas for or product manufacturer with any <br /> with a finished ceiling. This recessed questions. I <br /> pendent sprinkler uses one of the ems_ <br /> following: Sprinkler '..� <br /> • A two-piece Style 15 Recessed Identification ' <br /> Escutcheon with recessed adjust- <br /> ment up to 5/8 in. (15,9 mm) from <br /> the flush pendent position. Number (SIN) <br /> • A two-piece Style 20 Recessed TY313. . . . Upright 5.61K 1 2 in. NPT : ... <br /> Escutcheon with recessed adjust- <br /> ment up to 1/2 in. (12,7 mm) from TY323. . . .Pendent 5.61K, 1/2 in. NPT <br /> the flush pendent position. Technical <br /> The adjustment provided by the Data Operation <br /> Recessed Escutcheon reduces the <br /> accuracy to which the fixed pipe drops The glass bulb contains a fluid which <br /> to the sprinklers must be cut. Approvals expands when exposed to heat.When <br /> Intermediate level versions of Series Refer to Table A the rated temperature is reached, the <br /> TY-FRB Sprinklers are described in Maximum Working Pressure fluid expands sufficiently to shatter the <br /> Technical Data Sheet TFP357. Sprin- 175 psi(12.1 bar) glass bulb, allowing the sprinkler to <br /> kler guards and shields are described 250 psi(17.2 bar)` activate and water to flow. <br /> In Technical Data Sheet TFP780. 'The maximum working pressure of 250 psi(17.2 bar) pes i g n <br /> only applies to the listing by Underwriters Laborato- <br /> ries,Inc.(UL). <br /> Discharge Coefficient Criteria <br /> IMPORTANT K=5.6 GPM/psi'%(80,6 LPM/bar'%) The TYCO Series TY-FRB,5.6 K-factor, <br /> Refer to Technical Data Sheet Temperature Rating Upright (TY313) and Pendent (TY323) <br /> TFP2300 for warnings pertaining to Refer to Table A Sprinklers are intended for fire protec- <br /> regulatory and health information. Finishes tion systems designed in accordance <br /> Always refer to Technical Data Sprinkler: Refer to Table B with the standard installation rules <br /> Sheet TFP700 for the "INSTALLER recognized by the applicable Listing or <br /> WARNING" that provides cautions Recessed Escutcheon:White Coated, Approval agency (such as, UL Listing <br /> with respect to handling and instal- Black Coated,Chrome Plated,or Brass is based on the requirements of NFPA <br /> lation of sprinkler systems and com- Plated 13, and FM Approval is based on the <br /> ponents. Improper handling and Physical Characteristics requirements of FM's Loss Prevention <br /> installation can permanently damage Frame ............................Bronze Data Sheets).Only the Style 15 or Style <br /> a sprinkler system or its compo- Button......................Brass/Copper 20 Recessed Escutcheon is to be used <br /> nents and cause the sprinkler to fail Sealing Assembly ...Stainless Steel w/TEFLON for recessed pendent installations. <br /> to operate in a fire situation or cause Bulb...............................Glass <br /> it to operate prematurely. Compression Screw.................Bronze <br /> Deflector..........................Bronze <br /> Page 1 of 4 AUGUST 2018 TFP172 <br />