TFP530 <br /> Page 7 of 8 <br /> clearance hole, may delay the time to Limited Ordering <br /> sprinkler operation in a fire situation. <br /> A Vent Hole is provided in the Bulb Seat Warranty Procedure <br /> (Figure 1)to indicate if the Dry Sprinkler <br /> is remaining dry. Evidence of leakage For warranty terms and conditions,visit Contact your local distributor for <br /> from the Vent Hole indicates potential www.tyco-fire.com. availability. When placing an order, <br /> leakage past the Inlet seal and the need indicate the full product name and part <br /> to remove the sprinkler to determine number(P/N). <br /> the cause of leakage(e.g.,an improper <br /> installation or an ice plug). Close the Dry-Type Sprinkler <br /> fire protection system control valve and When ordering Series DS-2 Dry-Type <br /> drain the system before removing the Sprinklers, 11.21K Pendent,Standard(5 <br /> sprinkler. mm bulb) and Quick Response (3 mm <br /> bulb),and Standard Coverage,specify <br /> Sprinklers which are found to be the following information: <br /> leaking or exhibiting visible signs of <br /> corrosion must be replaced. • SIN: <br /> TY5255-Standard Response <br /> Automatic sprinklers must never be TY5235-Quick Response <br /> painted, plated, coated, or other- <br /> wise altered after leaving the factory. • Order Length: <br /> Modified sprinklers must be replaced. Dry-Type Sprinklers are furnished <br /> Sprinklers that have been exposed to based upon Order Length as <br /> corrosive products of combustion, but measured from the face of the <br /> have not operated,should be replaced ceiling to the face of the sprinkler <br /> if they cannot be completely cleaned fitting see Figures 2 through 5.After <br /> by wiping the sprinkler with a cloth or the measurement is taken, round it <br /> by brushing it with a soft bristle brush. to the nearest 1/4 in. increment. <br /> Care must be exercised to avoid • Inlet Connections: <br /> damage to the sprinklers - before, 1 in. NPT <br /> during, and after installation. Sprin- (Standard) <br /> klers damaged by dropping, striking, ISO 7-R 1 <br /> wrench twist/slippage,or the like, must (For information on ISO Inlet Thread <br /> be replaced. Also, replace any sprin- Connections, contact your Johnson <br /> kler that has a cracked bulb or that has Controls Sales Representative.) <br /> lost liquid from its bulb,see Installation Temperature Rating <br /> Section. <br /> The owner is responsible for the Sprinkler Finish <br /> inspection,testing,and maintenance of Escutcheon Type and Finish, as <br /> their fire protection system and devices applicable <br /> in compliance with this document, as Part Number from Table D <br /> well as with the applicable standards <br /> of the NATIONAL FIRE PROTECTION Replacement Escutcheons <br /> ASSOCIATION, such as NFPA 25, in Order replacement escutcheons <br /> addition to the standards of any other separately. <br /> authorities having jurisdiction. Contact Specify: (specify type),(specify)finish, <br /> the installing contractor or product P/N (specify): <br /> manufacturer with any questions. <br /> Flush and Recessed <br /> Automatic sprinkler systems are rec- White Color .......................854902 <br /> ommended to be inspected, tested, Chrome Plated.....................854912 <br /> and maintained by a qualified Inspec- Brass Plated.......................854922 <br /> tion Service in accordance with local Deep <br /> requirements and/or national codes. White Color .......................854802 <br /> Chrome Plated.....................854812 <br /> Brass Plated.......................854822 <br /> Sprinkler Wrench <br /> Specify W-Type 17 Sprinkler Wrench, <br /> P/N 56-010-4-118 <br /> Sprinkler Boot <br /> Specify Model DSB-2 Dry Sprinkler <br /> Boot, P/N 63-000-0-002 <br /> This Part Number includes one (1) <br /> Boot, two (2) Strap Ties, and 1/3 oz <br /> of Adhesive (a quantity sufficient for <br /> installing one boot). <br />