Laserfiche WebLink
Pipe Hangers <br /> TOLCO Fig. 200 - "Trimline" Adjustable Band Hanger <br /> TOLCO Fig. 20OF- "Trimline" Adjustable Band Hanger with Felt Lining for Copper Tubing <br /> TOLCO Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated <br /> TOLCO Fig. 200S - "Trimline" Adjustable Band Hanger with Removable Nut(For sizes 1"thru 2") <br /> Size Range: O t <br /> Fig. 200 - 1/2" (15mm)thru 8" (200mm) pipe A C US <9>1 <br /> Material: Steel, Pre-Galvanized Overall Height LISTED APPROVED <br /> B <br /> Function: For fire sprinkler and other general piping purposes. Knurled Center of pipe to top of knurled hanger rod nut. <br /> swivel nut design permits hanger adjustment after installation. D <br /> Top of pipe to bottom of hanger rod nut. <br /> Features: <br /> • 1/2" (15mm)thru 2" (50mm) sizes have flared edges for ease of Fig. <br /> installation on all pipe types and protects CPVC plastic pipe from 200--1/2& , <br /> abrasion. Captured knurled nut design (flared top) on 1"thru 2"sizes a 2001/4 D <br /> keep nut from separating with hanger. Hanger is easily installed ® l <br /> around pipe. tf )I <br /> * 1/2" (15mm), 3/4" (20mm), and 21/2" (65mm)thru 8" (200mm)) Spring <br /> tension on nut holds it securely in hanger before installation. Knurled ,Na <br /> nut is easily removed. <br /> * For (15mm) and 3/4" (20mm) sizes with non-captured knurl nuts <br /> order Fig. 200S <br /> Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) II Fig. <br /> in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and oo to 200-21hto200-8 <br /> 2 <br /> Factory Mutual Engineering Approved (FM) (3/4" (20mm)thru 8" (200mm)). 0-1 <br /> Conforms to Federal Specifications WW-H-171 E&A-A-1192A, Type 10 - <br /> 0-2 <br /> and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, <br /> Type 10. <br /> Maximum Temperature: 650'F (343'C) 40 <br /> Finish: Pre-Galvanized. Stainless Steel <br /> materials will be supplied with (2) hex nuts <br /> in place of a knurl nut. W <br /> c <br /> Order By: Part number and pipe size / <br /> f a <br /> ** Note: For metric hanger rod sizes add the i' a <br /> metric rod size to the figure number. ` <br /> Example: 200M8-11/2 or 200M10-11/2 <br /> Fig.200C Fig.20OF Fig.200 Fig.200&Fig.200S <br /> t M8 rod size is not UL Listed or FM Approved 20OC-1'/2 shown 200E-1'/2 shown shown with captured nut shown with <br /> 1"thru 2"sizes only non-captured nut <br /> Pipe Size Rod Size A B D Max.Rec.Load Approx.Wt./100 <br /> Part No.** in. (mm) in. mm** in. (mm) in. (mm) in. (mm) lbs. (M lbs. (kg) <br /> 200-1/2 '/2' (15) 3/8"-16 Wt or M10 T/a" (79.4) 21/8" (66.7) 1"/a2" (34.1) 400 (1.78) 11 (5.0) <br /> 2003/4 3/4" (20) 3/e"-16 Wt or M10 T/a" (79.4) 2'/2" (63.5) 1'/16" (27.0) 400 (1.78) 11 (5.0) <br /> 200-1 1" (25) 3/8"-16 Wt or M10 33/8" (85.7) 21/8" (66.7) 11/8" (28.6) 400 (1.78) 12 (5.5) <br /> 200-11/4 11/4" (32) 3/8"-16 Wt or M10 33/4" (94.0) 21/8" (73.0) 1a/32' (29.3) 400 (1.78) 13 (5.9) <br /> 200-11/2 11/2" (40) 3/8%16 Mt8 or M10 T/s' (98.4) 21/8" (73.0) 13h6" (30.2) 400 (1.78) 14 (6.4) <br /> 200-2 2" (50) 3/8"-16 M8t or M10 4'/2" (114.3) 39/5o" (80.8) 13/16" (30.2) 400 (1.78) 15 (6.9) <br /> 200-21/2 2'/2" (65) 3/8"-16 M10 5a/8' (142.9) 41/8" (104.7) 17/i6" (36.5) 600 (2.67) 27 (12.3) <br /> 200-3 T (75) 3/8%16 M10 57/8" (149.1) 4" (101.6) 11/4" (31.7) 600 (2.67) 29 (13.3) <br /> 200-31/2 T/2" (90) 3/8"-16 M10 73/s' (187.3) 51/4" (133.3) 23/16" (55.6) 600 (2.67) 34 (15.6) <br /> 200-4 4" (100) 3/8"-16 M10 73/8 (187.3) 5" (127.0) 13/8" (34.9) 1000 (4.45) 35 (16.0) <br /> 200-5 5" (125) 1/2%13 M12 9'/8' (231.8) 6'/4" (158.7) 3"/32" (84.9) 1250 (5.56) 66 (30.2) <br /> 200-6 6" (150) 1/2%13 M12 1078" (257.2) 63/4" (171.4) 2'/32" (56.3) 1250 (5.56) 73 (33.4) <br /> 200-8 8" (200) 1/2%13 M12 131/a" (333.4) 83/4" (222.2) 37/32" (81.7) 1250 (5.56) 136 (62.3) <br /> All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. <br /> B-Line series Fire Protection Solutions 23 Eaton <br />