My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1605 SE EVERETT MALL WAY WALMART 2025-09-10
>
Address Records
>
SE EVERETT MALL WAY
>
1605
>
WALMART
>
1605 SE EVERETT MALL WAY WALMART 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 2:48:40 PM
Creation date
8/21/2025 12:35:01 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1605
Tenant Name
WALMART
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
273
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pipe Hangers <br /> TOLCO Fig. 200 - "Trimline" Adjustable Band Hanger <br /> TOLCO Fig. 20OF- "Trimline" Adjustable Band Hanger with Felt Lining for Copper Tubing <br /> TOLCO Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated <br /> TOLCO Fig. 200S - "Trimline" Adjustable Band Hanger with Removable Nut(For sizes 1"thru 2") <br /> Size Range: O t <br /> Fig. 200 - 1/2" (15mm)thru 8" (200mm) pipe A C US <9>1 <br /> Material: Steel, Pre-Galvanized Overall Height LISTED APPROVED <br /> B <br /> Function: For fire sprinkler and other general piping purposes. Knurled Center of pipe to top of knurled hanger rod nut. <br /> swivel nut design permits hanger adjustment after installation. D <br /> Top of pipe to bottom of hanger rod nut. <br /> Features: <br /> • 1/2" (15mm)thru 2" (50mm) sizes have flared edges for ease of Fig. <br /> installation on all pipe types and protects CPVC plastic pipe from 200--1/2& , <br /> abrasion. Captured knurled nut design (flared top) on 1"thru 2"sizes a 2001/4 D <br /> keep nut from separating with hanger. Hanger is easily installed ® l <br /> around pipe. tf )I <br /> * 1/2" (15mm), 3/4" (20mm), and 21/2" (65mm)thru 8" (200mm)) Spring <br /> tension on nut holds it securely in hanger before installation. Knurled ,Na <br /> nut is easily removed. <br /> * For (15mm) and 3/4" (20mm) sizes with non-captured knurl nuts <br /> order Fig. 200S <br /> Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) II Fig. <br /> in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and oo to 200-21hto200-8 <br /> 2 <br /> Factory Mutual Engineering Approved (FM) (3/4" (20mm)thru 8" (200mm)). 0-1 <br /> Conforms to Federal Specifications WW-H-171 E&A-A-1192A, Type 10 - <br /> 0-2 <br /> and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, <br /> Type 10. <br /> Maximum Temperature: 650'F (343'C) 40 <br /> Finish: Pre-Galvanized. Stainless Steel <br /> materials will be supplied with (2) hex nuts <br /> in place of a knurl nut. W <br /> c <br /> Order By: Part number and pipe size / <br /> f a <br /> ** Note: For metric hanger rod sizes add the i' a <br /> metric rod size to the figure number. ` <br /> Example: 200M8-11/2 or 200M10-11/2 <br /> Fig.200C Fig.20OF Fig.200 Fig.200&Fig.200S <br /> t M8 rod size is not UL Listed or FM Approved 20OC-1'/2 shown 200E-1'/2 shown shown with captured nut shown with <br /> 1"thru 2"sizes only non-captured nut <br /> Pipe Size Rod Size A B D Max.Rec.Load Approx.Wt./100 <br /> Part No.** in. (mm) in. mm** in. (mm) in. (mm) in. (mm) lbs. (M lbs. (kg) <br /> 200-1/2 '/2' (15) 3/8"-16 Wt or M10 T/a" (79.4) 21/8" (66.7) 1"/a2" (34.1) 400 (1.78) 11 (5.0) <br /> 2003/4 3/4" (20) 3/e"-16 Wt or M10 T/a" (79.4) 2'/2" (63.5) 1'/16" (27.0) 400 (1.78) 11 (5.0) <br /> 200-1 1" (25) 3/8"-16 Wt or M10 33/8" (85.7) 21/8" (66.7) 11/8" (28.6) 400 (1.78) 12 (5.5) <br /> 200-11/4 11/4" (32) 3/8"-16 Wt or M10 33/4" (94.0) 21/8" (73.0) 1a/32' (29.3) 400 (1.78) 13 (5.9) <br /> 200-11/2 11/2" (40) 3/8%16 Mt8 or M10 T/s' (98.4) 21/8" (73.0) 13h6" (30.2) 400 (1.78) 14 (6.4) <br /> 200-2 2" (50) 3/8"-16 M8t or M10 4'/2" (114.3) 39/5o" (80.8) 13/16" (30.2) 400 (1.78) 15 (6.9) <br /> 200-21/2 2'/2" (65) 3/8"-16 M10 5a/8' (142.9) 41/8" (104.7) 17/i6" (36.5) 600 (2.67) 27 (12.3) <br /> 200-3 T (75) 3/8%16 M10 57/8" (149.1) 4" (101.6) 11/4" (31.7) 600 (2.67) 29 (13.3) <br /> 200-31/2 T/2" (90) 3/8"-16 M10 73/s' (187.3) 51/4" (133.3) 23/16" (55.6) 600 (2.67) 34 (15.6) <br /> 200-4 4" (100) 3/8"-16 M10 73/8 (187.3) 5" (127.0) 13/8" (34.9) 1000 (4.45) 35 (16.0) <br /> 200-5 5" (125) 1/2%13 M12 9'/8' (231.8) 6'/4" (158.7) 3"/32" (84.9) 1250 (5.56) 66 (30.2) <br /> 200-6 6" (150) 1/2%13 M12 1078" (257.2) 63/4" (171.4) 2'/32" (56.3) 1250 (5.56) 73 (33.4) <br /> 200-8 8" (200) 1/2%13 M12 131/a" (333.4) 83/4" (222.2) 37/32" (81.7) 1250 (5.56) 136 (62.3) <br /> All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. <br /> B-Line series Fire Protection Solutions 23 Eaton <br />
The URL can be used to link to this page
Your browser does not support the video tag.