My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1605 SE EVERETT MALL WAY WALMART 2025-09-10
>
Address Records
>
SE EVERETT MALL WAY
>
1605
>
WALMART
>
1605 SE EVERETT MALL WAY WALMART 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 2:48:40 PM
Creation date
8/21/2025 12:35:01 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1605
Tenant Name
WALMART
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
273
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pipe Hangers <br /> TOLCO Fig. 200H - Heavy Duty Band Hanger(For Trapeze) <br /> t <br /> Size Range: 2" (50mm)thru 4" (100mm)trapeze pipe size. C �L us <br /> Material: Steel—Pre-Galvanized LISTED <br /> Function: Designed primarily to support substantially heavier loads than <br /> is normally intended for the nominal hanger size. Used <br /> extensively to support trapeze installations and the increased loads from <br /> both above and below the trapeze assembly. <br /> Features: Furnished with 3/8"-16 or'/2"-13 adjusting threaded ring nut. <br /> Approvals: Underwriters Laboratories listed in the USA(UL)and B <br /> Canada (cUL). Conforms to Federal Specification WW-H-171 E & <br /> A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/ <br /> MSS SP-69&SP-58, Type 10. A <br /> Maximum Temperature: 650°F (343°C) <br /> Finish: Pre-Galvanized <br /> Order By: Figure number, pipe size and rod size. <br /> Important Design Note. Because of the increased loads applied to the <br /> trapeze assembly, both the upper trapeze supports as well as the lower <br /> hanging unit must be able to hold the maximum loads intended. Fig.200H Fig.200H <br /> t If using metric rods the M8 rod size is not UL Listed <br /> �- ------- ------- <br /> 1 <br /> _ 1 1 <br /> r � <br /> 1 1 1 <br /> .L _______ --______ <br /> Fig.200H <br /> v <br /> gyp' Fig.200 <br /> m <br /> d 's . <br /> m <br /> N <br /> Pipe Size Rod Size A B Approx.Wt./100 <br /> Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) <br /> 20OH-2-'/8 2" (50) 3/8"-161 49/I6" (115.9) T/32" (81.7) 48 (21.8) <br /> 20OH-2-1/2 2" (50) 1/2"-13 423/32" (119.8) 33/8" (85.7) 45 (20.4) <br /> 200H-21/23/8 2'/2" (65) 3/8"-161 59/I6" (134.9) 323/32" (94.4) 59 (26.7) <br /> 200H-21/2-1/2 2'/2" (65) 1/2"-13 5'a/32" (138.9) 37/8" (98.3) 56 (25.4) <br /> 20OH-3-3/8 3" (75) 3/a"-16t 53/4" (146.0) 327/32" (97.6) 63 (28.6) <br /> 20OH-3-1/2 3" (75) 1/2"-13 57/8" (148.1) 331/32" (100.8) 60 (27.2) <br /> 20OH-4-3/8 4" (100) 3/8%16t 67/8" (174.6) V/4' (112.7) 76 (34.5) <br /> 2001-11-41/2 4" (100) 1/2%13 T/32" (178.6) 4'9/32" (1116.7) 73 (33.1) <br /> Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. <br /> All sizes are UL Listed to support up to 8"pipe at max spacing per NFPA 13. <br /> For 6"(15omm)and 8"(200mm)trapeze pipe, consult factory. <br /> All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. <br /> Eaton 24 B-Line series Fire Protection Solutions <br />
The URL can be used to link to this page
Your browser does not support the video tag.