Pipe Hangers <br /> TOLCO Fig. 200H - Heavy Duty Band Hanger(For Trapeze) <br /> t <br /> Size Range: 2" (50mm)thru 4" (100mm)trapeze pipe size. C �L us <br /> Material: Steel—Pre-Galvanized LISTED <br /> Function: Designed primarily to support substantially heavier loads than <br /> is normally intended for the nominal hanger size. Used <br /> extensively to support trapeze installations and the increased loads from <br /> both above and below the trapeze assembly. <br /> Features: Furnished with 3/8"-16 or'/2"-13 adjusting threaded ring nut. <br /> Approvals: Underwriters Laboratories listed in the USA(UL)and B <br /> Canada (cUL). Conforms to Federal Specification WW-H-171 E & <br /> A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/ <br /> MSS SP-69&SP-58, Type 10. A <br /> Maximum Temperature: 650°F (343°C) <br /> Finish: Pre-Galvanized <br /> Order By: Figure number, pipe size and rod size. <br /> Important Design Note. Because of the increased loads applied to the <br /> trapeze assembly, both the upper trapeze supports as well as the lower <br /> hanging unit must be able to hold the maximum loads intended. Fig.200H Fig.200H <br /> t If using metric rods the M8 rod size is not UL Listed <br /> �- ------- ------- <br /> 1 <br /> _ 1 1 <br /> r � <br /> 1 1 1 <br /> .L _______ --______ <br /> Fig.200H <br /> v <br /> gyp' Fig.200 <br /> m <br /> d 's . <br /> m <br /> N <br /> Pipe Size Rod Size A B Approx.Wt./100 <br /> Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) <br /> 20OH-2-'/8 2" (50) 3/8"-161 49/I6" (115.9) T/32" (81.7) 48 (21.8) <br /> 20OH-2-1/2 2" (50) 1/2"-13 423/32" (119.8) 33/8" (85.7) 45 (20.4) <br /> 200H-21/23/8 2'/2" (65) 3/8"-161 59/I6" (134.9) 323/32" (94.4) 59 (26.7) <br /> 200H-21/2-1/2 2'/2" (65) 1/2"-13 5'a/32" (138.9) 37/8" (98.3) 56 (25.4) <br /> 20OH-3-3/8 3" (75) 3/a"-16t 53/4" (146.0) 327/32" (97.6) 63 (28.6) <br /> 20OH-3-1/2 3" (75) 1/2"-13 57/8" (148.1) 331/32" (100.8) 60 (27.2) <br /> 20OH-4-3/8 4" (100) 3/8%16t 67/8" (174.6) V/4' (112.7) 76 (34.5) <br /> 2001-11-41/2 4" (100) 1/2%13 T/32" (178.6) 4'9/32" (1116.7) 73 (33.1) <br /> Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. <br /> All sizes are UL Listed to support up to 8"pipe at max spacing per NFPA 13. <br /> For 6"(15omm)and 8"(200mm)trapeze pipe, consult factory. <br /> All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. <br /> Eaton 24 B-Line series Fire Protection Solutions <br />