Beam Clamps <br /> TOLCO Fig. 65 - Reversible Steel C-Type Beam Clamp 3/4" (19.omm)Throat Opening <br /> Size Range: <br /> Fig. 65 - 1/2"-13 rod sizes, and 5/8"-11 rod sizes C @11111111 <br /> Fig. 65XT - 3/e"-16 rod size (see below) LISTED <br /> Material: Steel with hardened cup point set screw and jam nut <br /> Function: Recommended for hanging from steel beam where flange thickness does B <br /> not exceed 3/4" 09.Omm). D <br /> Features: All steel construction eliminates structural deficiencies associated with <br /> casting type beam clamps. May be used on top or bottom flange of beam. (Beveled +F6" <br /> lip allows hanging from top flange where clearance is limited.) May be installed with <br /> set screw in up or down position. Offset design permits unlimited rod adjustment byallowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. <br /> Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada (cUL). <br /> Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, <br /> 3/8"-16 rod will support'/2" (15mm)thru 4" (100mm) pipe <br /> 1/2"-13 rod will support thru 8" (200mm) pipe Set Screw and <br /> Locknut Included <br /> Finish: Plain or Electro-Galvanized. Contact customer service for alternative finishes <br /> and materials. <br /> Order By: Figure number and finish <br /> Fig. 65 Patent#4,570,885 <br /> Part Rod Size B C D E <br /> No. A in. (mm) in. (mm) in. (mm) in. (mm) <br /> 65-1/2 1/2"-13 V/2" (38.1) 3/a" (19.0) 1" (25.4) 'h6" (14.3) <br /> 65-5/a 5/8"-11 V/i' (38.1) 3/4" (19.0) 1" (25.4) '/ia" (14.3) <br /> Part F Approx.Wt./100 <br /> No. in. (mm) Lbs. (kg) <br /> 65-1/2 V/4" (31.7) 55 (24.9) <br /> 65-5/8 V/4" (31.7) 55 (24.9) ' <br /> TOLCO Fig. 65XT - Reversible Steel C-Type Beam Clamp 3/4" (19.omm) Throat Opening <br /> Feature: Extruded holes allows for more thread V. <br /> engagement of threaded rod and set screw. � 125.4► c �L IS <br /> Finish: Plain or Electro-Galvanized LISTED tg . <br /> Order By: Figure number and finish ® (39.7) FM <br /> Approvals: Underwriters Laboratories Listed 6�e y APPROVED <br /> (cULus)and FM Approved (FM)for up to 4" 3/4' <br /> (100mm) pipe. h9.o► <br /> Designed to meet or exceed requirements of <br /> FM DS 2-0 and NFPA 13. set Screw and <br /> Locknut Included 7'/e' (22'2) <br /> (34.9) <br /> Part For Approx.Wt/100 <br /> No. Rod Size Lbs. (kg) <br /> 65XT 3/8"-16 28.0 (12.7) <br /> All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. <br /> Eaton 14 B-Line series Fire Protection Solutions <br />