1605 SE EVERETT MALL WAY WALMART 2025-09-10
>
Address Records
>
SE EVERETT MALL WAY
>
1605
>
WALMART
>
1605 SE EVERETT MALL WAY WALMART 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 2:48:40 PM
Creation date
8/21/2025 12:35:01 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1605
Tenant Name
WALMART
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
273
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REFRIGERATION SCHEDULE SYSTEM M TC Refrig.BAS: NOVAR Condenser Type: Air H/R Media: N/A Subcooler Liquid Temps SG1 Comp RGT'F: 50 DESIGN DB-F.' 87.8 EXTERIOR DRY BULB(DB)'F: 90.4 <br /> Format: Supercanter Store#: 3053 System Type: Machine Room/Central DX Primary Refrigerant: R407A System Elec: 460V 3Ph 6011z Sat.Cond.Temp'F: 103 H/R Use: N/A SG1 Liquid Temp 75 SG2 Comp RGT'F: N/A DESIGN WB'F: 86.3 Based on 5 yr Extreme DB-ASHRAE Pub.: Year 2017 <br /> Proto Size: Renovation City/State: Everett,WA Consultant: DCE Estimated Refrigerant Charge N/A Defrost Else: 208V 60Hz 1 or 3 Ph Cond Design TD'F: 15 H/R Water GPM: N/A SG2 Liquid Temp N/A SG3 Comp RGT°F: N/A DESIGN INTERIOR DRY BULB-F: 75 EXTERIOR WET BULB(WB)-F: 63.8 <br /> ProtoCycle Date: 11/11/2022 Date Prepared 2/22/2023 Prepared by: German Martinez Rack and Condenser(Ibs) -- Sys.Pilot Elec: 120V 1 Ph Summer H/R Avail: N/A H/R Glycol Type: N/A SG3 Liquid Temp N/A Evap.Superheat°F: 10 DESIGN INTERIOR RH%: 55% Based on 0.4%Monthly Max WB-ASHRAE Pub.: Year 2017 <br /> Fixture and Field Piping(Its) N/A Cond.El- 460V 3 Ph 60Hz Winter H/R Avail: N/A H/R Glycol%: N/A ELEVATION it: 82 <br /> CIRCUIT INFORMATION FIXTURE ELECTRICAL INFORMATION MISC INFORMATION <br /> Case Fixture Length/Quantity Walk-In Box Size LSHX V or N? Evaporator Case/ Lights Anti-Sweat <br /> Evaporator &Model# Coil TXV/ Sub-Circuit Load Circuit Evap Walk-In Circuit Control Valves Defrost Defrost Heaters: Fans Amps Amps <br /> CKT# FT/#of Doors 2 Dr/4' 3 Dr/6' 4 Dr/& 5 Dr/12' L W H Case Model Case/Coil Manuf. Application Model# WI Evaps Distributor Nozzle MBH Load MBH Temp Air Temp EPR LLSV Type Amps Voltage Amps Voltage ipg,� 12gv Amps Comments <br /> C01 20 FT 2 1 MDC-50LCDS/MDC-50LC SOUTHERN Home Meal Replacement - - 26.6 26 ETR CDST-7-9 E5S140 OT 1.3 120/1 ETR ETR EXISTING TO REMAIN N q <br /> CO2 16 FT 2 B3XC-LEP HUSSMANN M.D.Produce Island - - 17.5 26 ETR CDST4-7 E3S140 OT - 1.2 12011 ETR ETR EXISTING TO REMAIN <br /> CO3 8 FT 1 P4386 BORGEN Floral - - 10.8 26 ETR CDST4-7 E3S140 OT - 0.9 120/1 ETR ETR EXISTING TO REMAIN : a <br /> LLppaa � <br /> rc �3� <br /> C04 28 FT 2 1 05DM-NRG HILL PHOENIX M.D.Produce - - 31.9 34 ETR CDST-7-9 ESS140 OT - 1.6 12011 ETR ETR EXISTING TO REMAIN _ <br /> C05* 8 FT 1 BMD"*RD2020.642 HILL PHOENIX Service Deli 5.6 24 30 CDST-4** E3'* OT 1.2 120/1 0.7 Z ��B W`E=rc w LL W F <br /> O 3mz�"�oz z"+zz€z <br /> C06 24 FT 2 05DM-NRG HILL PHOENIX M.D.Deli - - 29.7 28 ETR CDST-9-7 E58140 OT - 1.4 120/1 ETR ETR EXISTING TO REMAIN r u.,e��z w;a w u o o a <br /> �u;oS oq�o <br /> C07 12 7 10 BOHN Poultry Cooler W.I. WKE-130 N/A EGVE-1-C/#1/2 9.8 28 ETR CDST4-5 E35140 EL 17.4 208/1 1.0 208/1 EXISTING TO REMAIN n o <br /> C08 12 8 10 BOHN Deli Cooler W.I. ADT-120 N/A EGVE-1-C/#1/2 9.8 26 ETR CDST4-5 E3S140 OT 1.8 120/1 EXISTING TO REMAIN _ 1z 11:3 w w . : <br /> C09 12 FT 1 C3NBRSS-WM CSC WORLDWIDE M.D.Cake - - T8 20 ETR CDST4-5 E3S140 OT - 1.2 120/1 ETR ETR EXISTING TO REMAIN <br /> C10 11 9 10 BOHN Bakery Cooler W.I. ADT-120 N/A EGVE-1-C/#1/2 10.0 26 ETR CDST-0-5 E3S140 OT 1.8 120/1 EXISTING TO REMAIN <br /> C11 32 FT 2 05DM-NRG HILL PHOENIX M.D.Producew/misters - - 36.5 28 ETR CDST-7-9 E58140 OT - 1.9 120/1 ETR ETR EXISTING TO REMAIN <br /> C12 36 FT 3 05DM-NRG HILL PHOENIX M.D.Produce w/misters - - 41.0 28 ETR COST-7-9 E9S250 OT - 2.1 120/1 ETR ETR EXISTING TO REMAIN <br /> C13 24 FT 2 OHMH-NRG HILL PHOENIX M.D.Meat 32.0 22 ETR CDST-7-9 E5S140 OT 2.0 120/1 ETR ETR EXISTING TO REMAIN [D <br /> C14 28 FT 1 OHMH-NRG HILL PHOENIX M.D.Meat - - 37.3 22 ETR CDST-11 E9S250 OT - 2.5 120/1 ETR ETR EXISTING TO REMAIN 2-_ <br /> C15 MAIN CIRCUIT-SUBCIRCUITS ARE BELOW 26 18 12 Poultry Cooler W.I. TOTAL MAIN CIRCUIT: 26.1 28 ETR CDST-7-7 E5S140 OT 5.4 120/1 CIRCUIT LOAD&ELECTRICAL ARE TOTALS OF THE SUBCIRCUITS <br /> W m <br /> C15a BOHN 1/2 Produce Cooler W.I. WK-180 N/A EGVE-1-C/#3/4 13.1 28 ETR OT - 2.7 120/1 EXISTING TO REMAIN <br /> C151, BOHN 1/2 Produce Cooler W.I. WK-180 N/A EGVE-1-C/#3/4 13.1 28 ETR OT - 2.7 120/1 EXISTING TO REMAIN rn _& <br /> C18 20 FT 1 1 05DM-NRG HILL PHOENIX M.D.Produce 24.7 26 ETR CDST-9-7 E5S140 OT 1.2 120/1 ETR ETR EXISTING TO REMAIN I Z.m ` <br /> C17 SPARE STUB - EXISTING TO REMAIN <br /> F W_z8 <br /> Z O <br /> Suction Group#1 Required Capacity MBH 357.1 18 ^F Saturated Suction Temperature A <br /> d <br /> General Notes: <br /> U <br /> 1, The scheduled data for existing to remain components,circuit loads,and electrical conditions are reproduced from original documents and may no/reflect as-built odni ilons, <br /> 2, Contractor shall field verify existing status of data shown for modified racks and notify engineer of any discrepancies. <br /> g) Owner's designated refrigeration equipment manufacturer:Hussmann <br /> 4, Original design dry bulb temp used. <br /> 5) OEM to update subcooler load at new design conditions. %O Z <br /> 6.) Case manufacturer to size new pulse width modulation electronic expansion valves for new cases with integrated case controllers. O O <br /> *MODIFIED CIRCUIT/*"NEW VALVE CASE OR EVAPORATOR <br /> V <br /> Z o <br /> _12 ¢. 0 <br /> M a <br /> REFRIGERATION SCHEDULE SYSTEM RCU-1 Q <br /> Sat.Cond.Temp°F: 100 DESIGN DB°F: 90.4 EXTERIOR DRY BULB(DB)-F: 90.4 > W z o <br /> Format: Supercenter Store#: 3053 System Type: Condensing Unit Primary Refrigerant: R448a Cond Design TD°F: 10 DESIGN WB°F: 63.8 Based on 5 yr Extreme DB-ASHRAE Pub.: Year 2017 System Electrical: 208V 3Ph 60Hz > W� o <br /> Proto Size: Renovation City/State: Everett,WA Consultant: DCE Evap.Superheat°F: 10 Liquid Temp 100 DESIGN INTERIOR DRY BULB'F: 75 EXTERIOR WET BULB(WB)-F: 63.8 W 0 N <br /> ProtoCyGe Date: 11/11/2022 Date Prepared: 2/22/2023 Prepared by: German Martinez Elevation ft: 82 Return Gas Temp'F: 30 DESIGN INTERIOR RH%: 55% Based on 0.4%Monthly Max WB-ASHRAE Pub.: Year 2017 0 � W 0 <br /> Case Fixture Length/Quantity Walk-In Box Size LSHX Y or N? Evaporator Case/ Liquid Line Lights Anti-Sweat (��7� LJ U) <br /> Evaporator &Model# Coil TXV/ Circuit Evap Walk-In Solenoid Defrost Defrost Heaters Fans Amps Amps Total Line L J <br /> CKT# Case Model Case/Coil Manuf. Application Model# WI Evaps Temp(F) Air Temp(F) Valve Length(ft) Suction Horiz(in) Suction Riser(in) Liquid Line(in) LL) <br /> FT/#of Doors 2 Dr/4' 3 Dr/6' 4 Dr/8' 5 Dr/12' L W H Distributor Nozzle Load(MBH) Type Amps Voltage Amps Voltage (120v) (120v) > <br /> RCU-1 13 11 10 KRACK 1/2 Pickup Freezer W.I. KRD44E-148TDAK SIZED BY OEM SIZED BY OEM 11.3 -16 -8 E5 EL 11.6 208/3 2.4 208/1 - - 50 1 1. 7/8 5/8 LLl <br /> z <br /> NOTES: <br /> O <br /> 1.)Owner's designated refrigeration equipment manufacturer:Hussmann <br /> 2.)RCU and all components are new. <br /> 3.)Condensers shall be furnished with coastal coating. <br /> ISSUE BLOCK <br /> REFRIGERATION SCHEDULE SYSTEM RCU-2 Sat.Cond.Temp-F: 100 DESIGN DB°F: 90.4 EXTERIOR DRY BULB(DB)'F: 90.4 <br /> Format: Supercenter Store#: 3053 System Type: Condensing Unit Primary Refrigerant: R448a Cond Design TO'F: 10 DESIGN WB'F: 63.8 Based on 5 yr Extreme DB-ASHRAE Pub.: Year 2017 System Electrical: 208V 3Ph 60Hz <br /> Proto Size: Renovation City/State: Everett,WA Consultant: DCE Evap.Superheat°F: 10 Liquid Temp 100 DESIGN INTERIOR DRY BULB-F: 75 EXTERIOR WET BULB(WB)'F: 63.8 <br /> ProtoCyGe Date: 11/11/2022 Dale Prepared: 2/22/2023 Prepared by: German Martinez Elevation it 82 Return Gas Temp°F: 30 DESIGN INTERIOR RH%: 55% Based on 0.4%Monthly Max WB-ASHRAE Pub.: Year 2017 <br /> Case Fixture Length/Quantity Walk-In Box Size LSHX Y or N? Evaporator Case/ Liquid Line Lights Anti-Sweat <br /> Evaporator &Model# Coil TXV/ Circuit Evap Walk-In Solenoid Defrost Defrost Heaters Fans Amps Amps Total Line <br /> CKT# Case Model Case/Coil Manuf. Application Model# WI Evaps Temp(F) Air Temp(F) Valve Length(ft) Suction Horiz(in) Suction Riser(in) Liquid Line(in) <br /> FT/#of Doors 2 Dr/4' 3 Dr/6' 4 Dr/8' 5 Dr/12' L W H Distributor Nozzle Load(MBH) Type Amps Voltage Amps Voltage (120v) (120v) <br /> RCU-2 13 11 10 KRACK 1/2 Pickup Freezer W.I. KRD44E-148TDAK SIZED BY OEM SIZED BY OEM 11.3 -18 -10 E5 EL 11.6 20. 2.4 208/1 - - 50 1 118 7/8 5/8 <br /> NOTES: <br /> 1.)Owners designated refrigeration equipment manufacturer:Hussmann <br /> 2.)RCU and all components are new. <br /> 3.1 Condensers shall be furnished with coastal coating. <br /> CHECKED BY: DL <br /> DRAWN BY: GM <br /> PROTO: 90 <br /> PROTO CYCLE: 11/11/22 <br /> REFRIGERATION SCHEDULE SYSTEM RCU-3 Sal.Cond.Temp'F: 105 DESIGN DB°F: 90.4 EXTERIOR DRY BULB(DB)'F: 90.4 DOCUMENT DATE: 02/22/23 <br /> Format: Supercenter Store#: 3053 System Type: Condensing Unit Primary Refrigerant: R448a Cond Design TO°F: 15 DESIGN WB-F: 63.8 Based on 5 yr Extreme DB-ASHRAE Pub.: Year 2017 System Electrical: 208V 3Ph 60Hz <br /> Proto Size: Renovation City/State: Everett,WA Consultant: DCE Evap.Superheat°F: 10 Liquid Temp 105 DESIGN INTERIOR DRY BULB-F: 75 EXTERIOR WET BULB(WB)OF: 63.8 <br /> ProtoCyGe Date: 11/11/2022 Date Prepared: ?1`2?M023 Prepared by: German Martinez Elevation ft: 82 Return Gas Temp°F: 50 DESIGN INTERIOR RH%: 55% Based on 0.4%Monthly Max WB-ASHRAE Pub.: Year 2017 <br /> Case Fixture Length/Quantity Walk-In Box Size LSHX Y or N? Evaporator Case/ Liquid Line Lights Anti-Sweat <br /> Evaporator &Model# Coil TXV/ Circuit Evap Walk-In Solenoid Defrost Defrost Heaters Fans Amps Amps Total Line <br /> CKT# Case Model Case/Coil Manuf. Application Model# WI Evaps Temp(F) Air Temp(F) Valve Length(ft) Suction Horiz(in) Suction Riser(in) Liquid Line(in) <br /> FT/#of Doors 2 Dr/4' 3 Dr/6' 4 Dr/8' S Dr/12' L W H Distributor Nozzle Load(MBH) Type Amps Voltage Amps Voltage (120v) (120v) <br /> RCU-3 17 13 10 KRACK Pickup Cooler W.I. GLD66D-268TDAA SIZED BY OEM SIZED BY OEM 20.9 26 34 E6 EL 20.9 208/1 3 208/1 50 1 1/e 7/8 5/8 <br /> NOTES: <br /> 1.)Owner's designated refrigeration equipment manufacturer:Hussmann <br /> 2.)RCU and all components are new. <br /> 3.)Condensers shall be furnished with coastal coating. <br /> OWNER FURNISHED REFRIGERATION EQUIPMENT SCHEDULE DOCUMENTS THAT DO NOT <br /> HAVE THE ARCHITECT OR <br /> Manufacturer VENDOR Type VOLTAGE QTY ENGINEER OF RECORD <br /> EMERSON HUSSMANN CORPORATION Condensing Unit-Ememon208 208 V 3 SEAL AND SIGNATURE <br /> KRACK HUSSMANN CORPORATION GL66D-268 206 V 1 SHALL BE CONSIDERED <br /> NOT FOR CONSTRUCTION <br /> KRACK HUSSMANN CORPORATION KR44E-148 208V 2 <br /> REFRIGERATION <br /> GENERAL INFORMATION(ALL NEW COILS): SCHEDULES <br /> I <br /> 1. COILS FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR. E(JUL <br /> 2. INFORMATION CONTAINED WITHIN THIS SCHEDULE IS FOR OWNER'S PURCHASING REPRESENTATIVE.REFER TO REFRIGERATION <br /> SCHEDULE(S)FOR SPECIFIC INFORMATION REGARDING EQUIPMENT. <br /> 3. SUPPLIER SHALL VERIFY PRODUCT REQUIREMENTS INCLUDING BUT NOT LIMITED TO LIQUID TO SUCTION HEAT EXCHANGER,EXPANSION <br /> DEVICE TYPE,ELECTRICAL REQUIREMENTS,ETC.WITH REFRIGERATION SCHEDULE(S). <br /> NOTES: <br /> A.❑EVAPORATOR COIL SHALL BE FURNISHED WITH FACTORY INSTALLED VALVES,SENSORS,TRANSDUCERS,AND ALL OTHER EXISTING CONDITIONS WERE TAKEN FROM EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING <br /> APPURTENANCES,AS OUTLINED IN THE❑15690 EQUIPMENT SPECIFICATION,INCLUDING:EXPANSION VALVE,SCHRADER VALVES(TWO IN THE ORIGINAL DRAWINGS AND MAY NOT REFLECT A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND <br /> SUCTION LINE,ONE IN THE LIQUID LINE,❑UPSTREAM OF THE EXPANSION VALVE),SUCTION PRESSURE TRANSDUCER,AIR TEMPERATURE EXACT"AS-BUILT'CONDITIONS.CONTRACTOR SPECIFICATIONS IN THEIR RELATED FIELD.THE FAILURE <br /> SENSOR,SUCTION TEMPERATURE SENSOR,DEFROST TERMINATION TEMPERATURE SENSOR AND ALL OTHER COMPONENTS.REFER TO SHALL FIELD VERIFY ALL EXISTING CONDITIONS TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES <br /> DETAILS FOR FIELD INSTALLED CONTROL WIRING BETWEEN EVAPORATOR COIL AND WALK-IN UNIT CONTROLLER. PRIOR TO SUBMITTING FINAL BIDS.CONTRACTOR NOT RELIEVE THE RESPONSIBILITY OF PERFORMING <br /> SHALL CAREFULLY COORDINATE NEW WORK AND THE WORK PROPERLY.NO ADDITIONAL SHEET: <br /> DEMOLITION WITH ALL OTHER DISCIPLINES AND COMPENSATION SHALL BE ALLOWED BECAUSE OF ^/'� <br /> EXISTING CONDITIONS. CONDITIONS THAT OCCUR DUE TO FAILURE TO KL <br /> FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. <br />