My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1605 SE EVERETT MALL WAY WALMART 2025-09-10
>
Address Records
>
SE EVERETT MALL WAY
>
1605
>
WALMART
>
1605 SE EVERETT MALL WAY WALMART 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 2:48:40 PM
Creation date
8/21/2025 12:35:01 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1605
Tenant Name
WALMART
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
273
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
•Capable of four(4),Class"B"circuits <br /> •Capable of two(2)Class"A"circuits <br /> •Capable of one(1)Class"A"circuit and two(2)Class"B"circuits <br /> •Capable of(8)Class"B"or four(4)Class"A"circuits with optional PS-EXP module <br /> •Temporal(Code 3),constant voltage output,Wheelock Sync output orTrue input to output follower mode <br /> •Built-in Wheelock synchronization mode that can be fed to any or all of the output circuits <br /> •Input and output can be synchronized with"IN>OUT SYNC"mode(DSM,2nd POWERPATH—or FACP with <br /> synchronization protocol is required) <br /> •Audible silence capability <br /> •Filtered and electronically regulated output <br /> •2.5 Amp auxiliary power limited output with reset capability.(Removed upon AC loss or alarm.Automatic reset 30 seconds after <br /> AC power returns or the alarm condition is over)or 0.075 Amps(PS-6)or 0.240 Amps(PS-8)of auxiliary power limited output <br /> which remains on during AC loss or an alarm condition when configured for 24 hour battery backup <br /> Supervision <br /> •Compatible with 12V or 24V(FWR or DC)FACP <br /> •Signaling appliance circuits are supervised and steered to either IN1 or IN2 <br /> •10K Ohm,1 Watt(Wheelock Model#MPEOL)End of Line Resistor(EOLR)for supervision of all outputs <br /> •37 distinguishable trouble diagnostics <br /> •AC loss trouble reported over a separate set of contacts(delay of 1 second) <br /> •All troubles are reported over the common trouble contacts(AC loss can have a delay of 30 seconds or 170 minutes) <br /> •Automatic switchover to standby battery when AC fails <br /> •Thermal and short circuit protection with auto reset <br /> •Input and output status LED indicators <br /> •AC fail supervision <br /> •Battery presence and low battery supervision <br /> •Ground Fault Detection,with diagnostics to indicate which circuit fault is on <br /> •Latching LED's for NAC trouble annunciation and Diagnostic trouble LED's(latching can be disabled) <br /> Power <br /> •Not Battery Dependent <br /> •Automatic switch over to standby batteries when AC fails <br /> •Supports sealed lead acid or gel type batteries <br /> •Fused battery protection <br /> •Thermal and short circuit protection with auto reset <br /> •Supports both 7AH or 12AH batteries in the same cabinet <br />
The URL can be used to link to this page
Your browser does not support the video tag.