My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1605 SE EVERETT MALL WAY WALMART 2025-09-10
>
Address Records
>
SE EVERETT MALL WAY
>
1605
>
WALMART
>
1605 SE EVERETT MALL WAY WALMART 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 2:48:40 PM
Creation date
8/21/2025 12:35:01 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1605
Tenant Name
WALMART
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
273
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AIR CURTAIN SCHEDULE MECHANICAL SYMBOLS <br /> AREA WEIGHT FAN MOTORS ELECTRICAL DATA <br /> MARK SERVED MANUFACTURER MODEL (LBS) HP 110LTS PH FLA MCA MOCP NOTES 18"x12" RECTANGULAR DUCT 18"WIDE <br /> AC 1 OGP BERNER CHD10-2072A 169 0.75 120 1 16.0 20.0 25 A,H,I,K,M BY 12"DEEP <br /> POWEREDAIRE ETA 2-72 <br /> GENERAL INFORMATION(ALL DEVICES): 12"4! 12"DIAMETER ROUND DUCT <br /> 1. AIR CURTAINS FURNISHED AND INSTALLED BY CONTRACTOR. <br /> 2. PROVIDE A DEDICATED ELECTRICAL CIRCUIT FOR EACH AIR CURTAIN WHEN MULTIPLE AIR CURTAINS ARE INSTALLED AT A SINGLE OPENING. <br /> SUPPLY DUCT IN SECTION <br /> NOTES: <br /> A. FURNISH WITH FACTORY MOUNTED NON-FUSED TOGGLE DISCONNECT SWITCH LOCATED ON TOP OF AIR CURTAIN. RETURN OR EXHAUST DUCT IN <br /> B. FURNISH WITH MANUFACTURER'S 120V PHOTOELECTRIC SENSOR SWITCH,SENSOR REFLECTOR,AND REQUIRED ACCESSORIES TO ENERGIZE ALL AIR CURTAINS SECTION <br /> AT EACH DOOR ON HIGH SPEED WHEN DOOR OPENS AND DE-ENERGIZE AIR CURTAINS WHEN DOOR CLOSES. <br /> C. UNIT SHALL BE TOP MOUNTED.FOR CURTAIN INSTALLATIONS NOT DETAILED ON ARCHITECTURAL DRAWINGS,SUSPEND CURTAINS FROM UNISTRUT INSTALLED �--I <br /> BELOW DOOR TRACK AND SPANNING ENTIRE DOOR OPENING AS REQUIRED.SUPPORT UNISTRUT FROM STRUCTURE. ELBOW WITH TURNING VANES <br /> D. AS REQUIRED,ALL OPENINGS WITH TWO AIR CURTAINS TO BE FURNISHED WITH A FIELD MOUNTED AND WIRED RELAY TO ALLOW FOR ONE SWITCH TO ACTIVATE III lii <br /> TWO AIR CURTAINS. <br /> E. BERNER UNIT SHALL BE FURNISHED WITH FACTORY INSTALLED SINGLE PHASE CONTROL PANEL,LEFT END. <br /> F. BERNER UNIT SHALL BE FURNISHED WITH TANDEM PERFORMANCE KITS. TEE WITH TURNING VANES <br /> G. BERNER UNIT SHALL BE FURNISHED WITH FACTORY INSTALLED INTELLISWITCH DIGITAL CONTROLLER. <br /> H. FURNISH WITH A FIELD MOUNTED AND WIRED 24V MAGNETIC LIMIT DOOR SWITCH AND TIME DELAY TO ENERGIZE AIR CURTAIN WHEN DOOR OPENS AND <br /> CONTINUE OPERATION FOR 60 SECONDS AFTER DOOR CLOSES. ROUND(OR OVAL)ELBOW "-' <br /> I. FURNISH WITH MANUFACTURER'S WALL MOUNTING PLATE FOR INSTALLATION ABOVE DOOR OPENING WITH BOTTOM OF UNIT FLUSH WITH TOP OF DOOR.IF AIR a z„LLp "'gF <br /> CURTAIN MUST BE OFFSET TO CLEAR DOOR HARDWARE OR OTHER OBSTRUCTION,UNIT SHALL BE TOP MOUNTED AND SUPPORTED FROM STRUCTURE. <br /> REFERENCE MECHANICAL AIR CURTAIN INSTALLATION DETAIL. �N ow>u LLrc VOLUME/BALANCE DAMPER aoa <br /> J. INSTALL BOTTOM OF AIR CURTAIN NO HIGHER THAN B'-0"AFF.INSTALL PER MANUFACTURER'S INSTRUCTIONS. Z �Yz 0wo= y =F <br /> K. AIR CURTAIN SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMCA 220. u = <br /> L. UNITS SHALL BE BLACK IN COLOR. SUPPLY AIR DIFFUSER WITH g 3Qi <w <br /> M. BERNER FURNISHED WITH FACTORY INSTALLED FAN SPEED CONTROL WITH TAMPER PROOF COVER. ROUND SUPPLY DUCT o ak w o G y z g <br /> =y o�'a€n'=� <br /> RETURN OR EXHAUST AIR DIFFUSER <br /> ao « <br /> AIR DEVICE SCHEDULE WITH ROUND DUCT <br /> MARK SERVICE MANUFACTURER MODEL STYLE FRAME TYPE FACE SIZE NOTES 24"x24" BRANCH DUCT AND/OR NECK SIZE u <br /> CD SUPPLY AIR TUTTLE&BAILEY S1200 ROUND NECK LAY-IN I..x24" B,D,E CD DIFFUSER OR GRILLE TYPE <br /> E.H.PRICE SCD CEILING DIFFUSER 450 CFM <br /> CARNES SFTB 0 $ <br /> CD1 SUPPLY AIR TUTTLE&BAILEY M ROUND NECK SURFACE REFER TO B,E,I,L,M,N C <br /> E.H.PRICE SMD CEILING DIFFUSER MOUNT DRAWINGS O THERMOSTAT U s <br /> CARNES SKFA <br /> RAG1 SUPPLY AIR TUTTLE&BAILEY M 1/2"xi/2"x1/2" SURFACE REFER TO C,E,I,M,N OS TIMER f2 <br /> E.H.PRICE SMD EGGCRATE MOUNT DRAWINGS < `N <br /> CARNES SKFA CEILING GRILLE <br /> TEMPSENSOR <br /> RAW RETURN AIR TUTTLE&BAILEY T75 FIXED BLADE SURFACE REFER TO B,E,I <br /> SX <br /> E.H.PRICE 510Z WALL GRILLE MOUNT DRAWINGS 0 w <br /> CARNES RSRBH CONNECT TO EXISTING p <br /> SAW SUPPLY AIR TUTTLE&BAILEY T64 LOUVERED FACE SURFACE REFER TO B,E,F,H <br /> E.H.PRICE 52ODS REGISTER MOUNT DRAWINGS ETR EXISTING TO REMAIN <br /> CARNES RTDBV <br /> VOLUME/BALANCE DAMPER SCHEDULE <br /> FIRE DAMPER <br /> TYPE MANUFACTURER/MODEL Fo <br /> ROUND AES/WMVCD O 0 Z <br /> RUSKIN/WMRS25 O O O <br /> RECTANGULAR AES/AMD4 O 0 <br /> RUSKIN/WMD25 U1 Q <br /> GENERAL INFORMATION(ALL DEVICES): <br /> 1. INSTALL BOTTOM OF WALL MOUNTED AIR DEVICES AT ELEVATION INDICATED ON DRAWINGS UNLESS NOTED OTHERWISE. <br /> 2. BALANCE DAMPER CONTACTS:❑ _ N ~ <br /> AES-(800)786-0402 (n <, a <br /> RUSKIN-(816)761-7476 Q O <br /> o wM <br /> NOTES: W 0 o <br /> A. 6-WAY(DBi-DB3)OR 4-WAY(DB4-DB8)THROW UNLESS SHOWN OTHERWISE WITH FLOW ARROWS ON PLAN. W Z <br /> N <br /> B. ALL STEEL CONSTRUCTION. j W <br /> C. ALL ALUMINUM CONSTRUCTION. W V <br /> D. BRANCH DUCT SIZE SHALL BE SAME AS NOTED DIFFUSER NECK SIZE UNLESS NOTED OTHERWISE. O U J LU O N <br /> E. STANDARD WHITE FINISH. <br /> F. PROVIDE NECK FOR DUCT CONNECTION. L N <br /> G. DROP BOX DIFFUSERS FURNISHED BY OWNER INSTALLED BY CONTRACTOR.REFERENCE SPECIFICATIONS. Lt.l <br /> H. PROVIDE INTEGRAL OPPOSED BLADE DAMPERS ON ALL DRUM LOUVERS ON DROP BOXES WITH BRANCH DUCTWORK ATTACHED TO THE SUPPLY PLENUM. <br /> I. PROVIDE MANUFACTURER'S OPPOSED BLADE DAMPER ACCESSIBLE THROUGH FACE UNLESS NOTED OTHERWISE. W <br /> J. PROVIDE WITH FASTENERS FOR COMPLETE(NON-HINGED)REMOVABILITY OF GRILLE.DO NOT PROVIDE FILTER UNLESS NOTED OTHERWISE. w <br /> K. TWO 2"SLOTS WITH MANUFACTURER'S INSULATED PLENUM(TUTTLE&BAILEY LP,PRICE JSPI,CARNES CXPC.) <br /> L. REFER TO PLANS FOR DIRECTIONAL ARROWS INDICATING CFM THROWS FOR PROPER GRILLE SELECTION.NO DIRECTIONAL ARROWS INDICATES 4-WAY <br /> THROW. <br /> M. PROVIDE ROUND NECK ADAPTER 0 <br /> N. PROVIDE CEILING TRANSITION REGISTER BOX WITH 16"OR 24"PLATE FOR ROUGH-IN. <br /> ISSUE BLOCK <br /> CHECKED BY: JEE <br /> DRAWN BY: RGD <br /> PROTO: 90 <br /> PROTO CYCLE: 11/11/22 <br /> DOCUMENT DATE: 02/22/23 <br /> TOP BEAM <br /> CLAMP TYP <br /> 3" <br /> MAX TOP CHORD OF JOIST ROOF <br /> ROOF <br /> 2"x2"x1/4"ANGLE OR <br /> 6" 1 5l8"xi 5l8"UNISTRUT <br /> NOT FOR <br /> DUCT HANGER STRAP <br /> 6" <br /> REF SPECIFICATIONS CONSTRUCTION <br /> REFSTRUCTURALFOR LOADS MUST BE LOADS MUST BE <br /> BOTTOM OF <br /> ATTACHMENT HUNG WITHIN 3" 1"MIN. HUNG WITHIN 3" <br /> OF PANEL POINTS STRUCTURE OF PANEL POINTS <br /> REF STRUCTURALFOR REFSTRUCTURAL <br /> MOUNTING DETAIL THREADED ROD SCREWS TYP <br /> TYP 60"MAX. <br /> SHEET METAL <br /> RECTANGULAR DUCT REFSTRUCTURAL <br /> 2"x2"xi/4"ANGLE OR <br /> RECTANGULAR DUCT 1 5/8"x1 5/8"UNISTRUT RECTANGULAR DUCT <br /> OFFSET AWAY NOTE:AIR CURTAIN IS REQUIRED TO BE PERPENDICULAR TO STRUCTURE PARALLEL TO STRUCTURE <br /> FROM WALL INSTALLED 3/8 INCH(BERNER)OR 1/2 INCH <br /> AIR CURTAIN (POWERED AIRE)AWAY FROM WALL FOR LOADS MUST BE <br /> EVERY INCH ABOVE CLEAR DOOR OPENING <br /> DOOR OPTIONAL ROUTING BEAM CLAMP <br /> HARDWARE HUNG WITHIN 3" IN CONCEALED DUCT HANGER STRAP <br /> (IF APPLICABLE) �( MAX OF PANEL POINTS AREAS REF SPECIFICATIONS <br /> 1` 3^ REF STRUCTURAL <br /> ROOF ROOF <br /> OFFSET ABOVE CLEAR <br /> DOOR OPENING 2"x2"xi/4"ANGLE OR <br /> TOP OF 1 5/8"x1 5/8"UNISTRUT <br /> ENTRY DOOR <br /> 6„ 6 <br /> L=W/4,4"MIN <br /> /, /` BOTTOM OF <br /> STRUCTURE LOADS MUST BE <br /> DUCT HANGER STRAP OF PANEHUNG L POINTS <br /> REFREF SPECIFICATIONS .yAO SCREWS TYP <br /> P PP P� NP` go DUCTSUPPORTBAND <br /> EXTERIOR INTERIOR I / AIR ND DUCT <br /> PPLY ��`5 0SO3 SAME SIZE AS STRAP MECHANICAL <br /> LOAD RATED 7,6 <br /> FASTENERS DETAILS AND <br /> NOTES: W SCHEDULES <br /> 1.ENSURE AIR CURTAIN INSTALLATION ALLOWS PROPER DOOR OPERATION,AIR CURTAIN AIRFLOW, SUPPLY REGISTER,REF FLOOR PLAN FOR SIZE <br /> ❑ AND ACCESS TO AIR CURTAIN AND DOOR HARDWARE(IF APPLICABLE)FOR MAINTENANCE. AND LOCATION,MOUNT REGISTERS @ 30 DEGREE <br /> 2.AIR CURTAIN IS REQUIRED TO BE OFFSET FROM WALL IF INSTALLED HIGHER THAN 1"ABOVE DOOR ANGLE DOWN FROM HORIZONTAL IN OPEN OFFICES <br /> ❑ OPENING. AND STOCKROOM AREA,EXCEPT THOSE ROUND SUPPLY <br /> 3.FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS AND POST-INSTALLATION AIRFLOW SHOWN ON BOTTOM OF DUCT ON THE PLAN AIR DUCT <br /> ❑ PATTERN VERIFICATION,REF SPECIFICATIONS. NOTES: <br /> 1.SPIN-IN FITTINGS W/SCOOPS ARE NOT ACCEPTABLE PERPENDICULAR TO JOIST PARALLEL TO JOIST <br /> 2.REF PLANS FOR RUNOUT SIZES <br /> 3.45"LEAD IN <br /> 0IAIR CURTAIN INSTALLATION �,�HIGH EFFICIENCY BRANCH DUCT FITTING �DUCT SUPPORT AND GRILLE SHEET: <br /> NTS L NTS <br /> NTS ^n 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.