Laserfiche WebLink
KEYNOTES <br /> 15.700 REMOVE AIR DEVICES AND DUCTWORK SHOWN <br /> DASHED UNLESS OTHERWISE NOTED AND CAP <br /> OFF DUCTWORK TO REMAIN.PATCH AND SEAL <br /> DUCTWORK AS NEEDED INCLUDING SEALING <br /> DUCTWORK TO REMAIN PER SPECIFICATIONS. <br /> 15.705 CONNECT TO EXISTING SUPPLY/RETURN <br /> DUCTWORK INDICATED. <br /> O <br /> O �— <br /> F H; H�HHU <br /> ozk EW�G =g <br /> - o80 < <br /> N <br /> E C <br /> 7 �8 <br /> Z 8� <br /> Z tA) <br /> ON <br /> 00 Z <br /> 0 oO <br /> 0 1 'a <br /> Jr O <br /> = JN r <br /> O <br /> Q <br /> >o 0 <br /> Z <br /> W <br /> o uJ U)o <br /> w <br /> uJ � W <br /> Z <br /> 0 <br /> 0 <br /> ISSUE BLOCK <br /> May need to change supply <br /> Diffuser size larger to match <br /> duct and add an Oposed <br /> Blade Damper <br /> 11 13 <br /> le e <br /> MANAGER TRAINING UP UPS E Q Q O <br /> SUPPORT 12"x12" R SAG' BREAKROOM <br /> CD CD ETR <br /> ETR ETR 4" HALLWAY <br /> SAW RAG MEN <br /> — 600 18"0 ETR ETR CHECKED BY: JEE <br /> CD 14"x14"ETR <br /> 10"0 ETR 15.705 <br /> ETR S20 <br /> 16'x16"ETR 14.0 TYP - 18"0 DRAWN BY: RGD <br /> ETR <br /> d IIm� 14"x14" — PROTO: 90 <br /> �J�J ETR S 19 W W MEN' —I 10 PROTO CYCLE: 11/11/22 <br /> RTU-20 / <br /> RTU-19 12"x1 TR 5 TON DOCUMENT DATE: 02122I23 <br /> HALLWAY STON 1650 RTU-21 <br /> 1650 ETR STON <br /> ETR 1650 <br /> ETR <br /> REAR OF E AREA MECHANICAL PLAN <br /> 2 <br /> NOT FOR <br /> Make grill size CONSTRUCTION <br /> to match duct <br /> better <br /> 11 12 13 <br /> MGR 12"x12"ETR UPC/ <br /> SUPPORT TRAINING PERSONAL I INVOICING CD UPS <br /> OFFICE CD <br /> ETR CID I I I ETR- LMEN \ L <br /> ETR Ct--��F--din rI �� <br /> ETR RAG 6xM"ETR 'F1I—I-�' I 18"0 ETR ETR -JI <br /> i" IG'1� I <br /> 14"x14"ETR ETR 14"0 ETR I �_ ETR <br /> 10"0 ETR 5-1 5-20 IER'S I BREAKROOM <br /> __J /T <br /> r i'Jt <br /> C ❑ <br /> RTU-21 <br /> 5TON <br /> L9 — — -- —J r� <br /> 5 TON 12"x12"ETR 5 TON J 1-,0 1650 DEMO DIFFUSERS, 1650 ETR <br /> ETR BRANCH DUCT AND — <br /> MAIN ASSHOWN ETR 5-21 <br /> 15.700 <br /> ENLARGED <br /> REAR OFFICE AREA MECHANICAL DEMO PLAN MECHANICAL <br /> ' 1/8"=V-0" PLANS <br /> APPROVED <br /> Offce of Community,Planning&Economic Development <br /> PLANNING DEPARTMENT <br /> NAME: Jessica J—i EXISTING CONDITIONS WERE TAKEN FROM EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING <br /> DATE: 11/07/2023 ORIGINAL DRAWINGS AND MAY NOT REFLECT A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND <br /> EXACT"AS-BUILT"CONDITIONS.CONTRACTOR SPECIFICATIONS IN THEIR RELATED FIELD.THE FAILURE <br /> SHALL FIELD VERIFY ALL EXISTING CONDITIONS TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES <br /> PRIOR TO SUBMITTING FINAL BIDS.CONTRACTOR NOT RELIEVE THE RESPONSIBILITY OF PERFORMING <br /> SHALL CAREFULLY COORDINATE NEW WORK AND THE WORK PROPERLY.NO ADDITIONAL SHEET: <br /> DEMOLITION WITH ALL OTHER DISCIPLINES AND COMPENSATION SHALL BE ALLOWED BECAUSE OF M 1 <br /> EXISTING CONDITIONS. CONDITIONS THAT OCCUR DUE TO FAILURE TO <br /> FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. <br />