SPECIALTY PLUMBING FIXTURE SCHEDULE TOILET PLUMBING FIXTURE SCHEDULE PLUMBING SYMBOLS
<br /> MARK FIXTURE MANUFACTURER MODEL FIXTURE DESCRIPTION ALL PRODUCTS ON THIS SCHEDULE ARE FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR.REFER TO SPECIFICATIONS.
<br /> WPG WATER PRESSURE AMETEK 656 2.5 INCH STAINLESS STEEL CASE,ALL WETTED PARTS STAINLESS STEEL, BRANCH SIZES(MIN) -SS- SANITARY SEWER
<br /> GAUGE TRERICE D83LFSS LIQUID FILLED,1/4 INCH NPT CONNECTOR,1.6%ACCURACY,30"HG VAC
<br /> WEISS INSTRUMENTS LF252 TO 100 PSI RANGE. MARK FIXTURE CW HW WASTE VENT MANUFACTURER MODEL TRIM AND ACCESSORIES NOTES —GW— GREASE WASTE
<br /> WHA WATER HAMMER JOSAM SERIES 75000 LEAD FREE CONFORM TO PDI WH-201,ANSI Al12.26.1M,ASSE 1010. L17 LAVATORY DECK 112" 1/2" 1 1/2" 1 1/2" VERONA SM00046-3SCN VERONA:WALL MOUNTED,ONE-PIECE QUARTZIA DECK(BIANCO SAND) F
<br /> ARRESTOR PRECISION PLUMBING PRODUCTS STAINLESS STEEL#316 SERIES 3-STATION REMBRANDT RSM-UM7300-90"-00-SB REMBRANDT:WALL MOUNTED,ONE-PIECE QUARTZ DECK(SNOW BLIND) —OW— OIL WASTE
<br /> WATTS SS SERIES BOWL:CHINA SHELL CH-6360 UNDERMOUNT 18"x13"CHINA BOWL(S)
<br /> WILKINS MODEL 1250XL SERIES VERONA BASE:ACORN EN1121AO-002 ENVIRO-GLAZED WHITE ENCLOSURE.
<br /> JAY R.SMITH HYDROTROLS REMBRANDT BASE:METZFAB MET-PRT420-000 WHITE ENCLOSURE. —ST— STORM SEWER
<br /> SIOUX CHIEF HYDRA-RESTER FAUCET:TOTO TEL145-D1OE#CP-0.5 GPM SENSOR OPERATED SELF-GENERATING POWER SYSTEM.CHROME PLATED BRASS P-TRAP
<br /> MI
<br /> FCH MWH WITH CLEANOUT,GRID STRAINER WITH TAILPIECE. —RD— ROOF DRAIN LINE
<br /> CONNECTION ACCESSORIES:(2)STOP VALVES PER DECK,THERMOSTATIC MIXING VALVE KIT(TMV,HOSES&FITTINGS)SET TMV TO 105'F.
<br /> FCV30 FLOW CONTROL BELL&GOSSETT #CB LF"CIRCUIT SETTER PLUS" LEAD FREE NAMEPLATE AND 1/2"VALVE BODY SIZE UNLESS SHOWN TMV:ZURN ZW1070XL
<br /> VALVE FLOW DESIGN ICSS050 OTHERWISE ON PLANS.SET AND BALANCE TO 0.25 GPM OR PROVIDE —ORD— OVERFLOW ROOF DRAIN LINE
<br /> 0.25 GPM CARTRIDGE UNLESS SHOWN OTHERWISE ON PLANS AND PER GENERAL INFORMATION(ALL FIXTURES):❑
<br /> MANUFACTURER'S INSTALLATION INSTRUCTIONS. 1. SUBSTITUTIONS NOT PERMITTED.REF SPECIFICATIONS FOR APPROVED MANUFACTURERS OF THE FOLLOWING TRIM AND ACCESSORIES: —-— DOMESTIC COLD WATER
<br /> C -P-TRAP WITH CLEANOUT PLUG:POLISHED CHROME-PLATED TUBULAR BRASS,17 GAUGE WITH BRASS NUTS AND SLIP INSERTS.
<br /> E) -SS BRAIDED WATER SUPPLY:FLEXIBLE BRAIDED STAINLESS STEEL(SS)OUTER SHEATHING WITH REINFORCED PVC INNER TUBING.
<br /> —--- o
<br /> DCV DOUBLE-CHECK VALVE WATTS SS007QT-S ASSE 1015,316 STAINLESS STEEL BODY,QUARTER TURN TEST COCKS, El -STOP VALVES:CHROME PLATED BRASS,QUARTER TURN ANGLE STOP VALVES. DOMESTIC HOT WATER w = o o.>
<br /> BACKFLOW PREVENTER QUARTER TURN,FULL PORT BALL VALVES AND STAINLESS STEEL NOTES:❑ DOMESTIC HOT WATER RETURN H �` �i 1
<br /> (STAINLESS STEEL) STRAINER. A. FURNISH WITH 1/2"X33/4"STAINLESS STEEL SIMPSON WEDGE-ALL WEDGE ANCHORS FOR ALL FIOOR MOUNTED FIXTURE CARRIERS. w ��wrpwa=3ri
<br /> B. REFERENCE ARCHITECTURAL DRAWINGS FOR EWC2 ORIENTATION. �w LLp Win°
<br /> BARRIER-TYPE TRAP SURE SEAL $S4009 INLINE FLOOR DRAIN TRAP SEAL.ASSE 1072 C. COORDINATE WATER ROUGH-IN HEIGHT FROM MANUFACTURER'S INSTALLATION INSTRUCTIONS WITH GRAB BAR LOCATION.REF ARCH. —IW— IRRIGATION WATER c0 rcris�'-°arc
<br /> SEAL PROTECTION JAY R SMITH 2692 D. USE SAME MANUFACTURER FOR URI AND UR2.
<br /> E. FURNISH WITH LAVATORY DECKASSEMBLY FIXTURE ANDTRIM. —T— TEPID OR TEMPERED WATER O
<br /> — CHECK VALVES RED-WHITE 232 BRASS JACKET WITH PLASTIC VALVE ASSEMBLY r °Wi�3rc w3 o€a F¢
<br /> APOLLO SERIES 61-100
<br /> CRANE 1191 WASTE PUMP SCHEDULE _F_ FILTERED WATER oaW EowGyww O'o"-';
<br /> WATTS 6 F Sao Fo' 0
<br /> NIBCO T-413 ALL PRODUCTS ON THIS SCHEDULE ARE FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR.REFER TO SPECIFICATIONS. m d°a„arc=rcrc«
<br /> —G— NATURAL GAS
<br /> — DOUBLE-CHECK WATTS LF007QT OR LF709 LEAD FREE,INCLUDE TWO INDEPENDENT-ACTING CHECK VALVES,TWO ELECTRICAL HEAD
<br /> VALVE BACKFLOW BEECO FDC-LF SHUT-OFF VAVLES AND REQUIRED MEANS FOR TESTING FOR EACH MARK SERVICE MANUFACTURER MODEL HP V I PHI HZ GPM (FT) DESCRIPTION —A— COMPRESSED AIR uJ
<br /> PREVENTER FEBCO LF850 ASSEMBLY.MINIMUM 175 PSI WORKING PRESSURE.
<br /> WILKINS 350XL OR 950XLT2 P11 WASTE PUMP WITH LITTLE GIANT VCL45ULS 0.2 120 1 60 4.0 25 PROVIDE PUMP WITH 1 GALLON BASIN WITH 21-1/8"DIAMETER INLET OPENINGS,INTEGRAL FLOAT $
<br /> BASIN SWITCHES,6'POWER CORD,AND CHECK VALVE ON DISCHARGE. —CD— CONDENSATE DRAIN
<br /> — LOCKABLE RED-WHITE 5042 BRASS BALL VALVES WITH PLASTIC JACKETED LEVER TYPE HANDLE. (MULTI USE) Ns
<br /> SHUTOFF APOLLO SERIES 70LF-100
<br /> VALVES CRANE U s
<br /> —RO— REVERSE OSMOSIS WATER C
<br /> WATTS LFB-6000 00 OR OR LF LFB-6001
<br /> PLUMBING FIXTURE SCHEDULE -v- PLDMBING VENT z
<br /> --- REDUCED WATTS LF0094T OR LF909 LEAD FREE,PROVIDE STRAINER,SHUT-OFF VALVES AND TEST COCKS:
<br /> PRESSURE BEECO FRP-LF INSTALL DRAIN LINE WITH AIR GAP ASSEMBLY TO RECEPTOR APPROVED ALL PRODUCTS ON THIS SCHEDULE ARE FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR.REFER TO SPECIFICATIONS. —vAC— PLUMBING VACUUM #WA
<br /> BACKFLOW FEBCO LF860 BY AUTHORITY HAVING JURISDICTION.MINIMUM 175 PSI WORKINGPREVENTER WILKINS 375XL OR 975XL PRESSURE. BRANCH SIZES(MIN)MARK FIXTURE CW HW WASTE VENT MANUFACTURER MODEL DESCRIPTION,TRIM AND ACCESSORIES NOTES UNION 0N
<br /> REDUCED WATTS SS009M3QT-S LEAD FREE,STAINLESS STEEL REDUCED PRESSURE ZONE ASSEMBLY. SS1 SERVICE SINK 3/4" 3/4" 3" 2" STERN-WILLIAMS SB-800 CHROME PLATED FAUCET WITH INTEGRAL CHECK VALVES,HOSE,BRACKET(MOUNT e �y�
<br /> PRESSURE FURNISHED WITH STAINLESS STEEL STRAINER,VANDAL RESISTANT (TERRAZZO) FIAT TSB-200 DIRECTLY ABOVE WALL GUARD),MOP HANGER(60"AFF). Dd GAS PRESSURE REGULATOR
<br /> BACKFLOW TEST COCKS,AND FULL PORT QUARTER TURN BALL VALVE SHUTOFFS. 24"x 24"x 12" ACORN TSH-24-SSC-LB FAUCET:CHICAGO 897-CP(DISCARD STANDARD SUPPLY ARMS&CONNECT(2)GCJKCP x
<br /> PREVENTER INSTALL DRAIN LINE WITH AIR GAP ASSEMBLY TO RECEPTOR APPROVED SUPPLY ARMS USING(2)897-020JKRCF ADAPTERS),ZURN Z843M1-CS,T&S BRASS V GAS COCK
<br /> (STAINLESS STEEL) BY AUTHORITY HAVING JURISDICTION.MINIMUM 175 PSI WORKING B-0665-BSTP W/ETERNA CARTRIDGES&SPRING CHECKS.
<br /> PRESSURE. HOSE/BRACKET:STERN WILLIAMS T-35,FIAT 832-AA,ACORN KH36. C
<br /> MOP HANGER:STERN WILLIAMS T-40,FIAT 889-CC,ACORN KMH. ELBOW-TURNED DOWN O 0 Z
<br /> STRAINER WATTS LF777SI CAST BRONZE Y-STRAINER WITH BALL VALVE GENERAL INFORMATION(ALL FIXTURES):C
<br /> APOLLO 59-004-06 0— ELBOW-TURNED UP O O O
<br /> 1. SUBSTITUTIONS NOT PERMITTED.REF SPECIFICATIONS FOR APPROVED MANUFACTURERS OF THE FOLLOWING TRIM AND ACCESSORIES:
<br /> TRAP PRIMER PRECISION PLUMBING PRODUCTS PRIME RITE OR OREGON#1 LEAD FREE,PROVIDE ALL BRONZE PRIMER VALVE WTIH REMOVABLE -P-TRAP WITH CLEANOUT PLUG AND SINK CONTINUOUS WASTES:POLISHED CHROME-PLATED TUBULAR BRASS,17 GAUGE WITH BRASS NUTS AND SLIP INSERTS.
<br /> (M El
<br /> TRAPS) MIFAB M-500-NPB OPERATING PARTS,INTEGRAL VACUUM BREAKER,GASKETED ACCESS El -SS BRAIDED WATER SUPPLY:FLEXIBLE BRAIDED STAINLESS STEEL(SS)OUTER SHEATHING WITH REINFORCED PVC INNER TUBING. TEE-TURNED DOWN O 0 0 Q
<br /> JOSAM 88300 COVER,AND MULTIPLE TRAP CAPABILITY ❑ -STOP VALVES:CHROME PLATED BRASS,QUARTER TURN ANGLE STOP VALVES. Z �i O
<br /> SIOUX CHIEF SERIES 695 NOTES:❑ ---C— TEE-TURNED UP = N ~O
<br /> — TRAP PRIMER PRECISION PLUMBING PRODUCTS PRIME-RITE OR OREGON#1 LEAD FREE,PROVIDE ALL BRONZE PRIMER VALVE WITH REMOVABLE A. MOUNT EYEWASH 36"AFF TO TOP OF HEAD SPRAY. (n a
<br /> (SINGLE TRAP) SIOUX CHIEF 695 OPERATING PARTS,INTEGRAL VACUUM BREAKER,AND GASKETED B. INSTALL MOP SINK FAUCET AT 32"AFF AND LOCATE TWO MOP HANGER BRACKETS SIDE BY SIDE NEAR MOP SINK. 0 a BALL VALVE Q M
<br /> ACCESS COVER. C. FURNISH WITH ZURN TMV(MODEL ZW3870XLT)UNLESS SERVED WITH TEMPERED WATER OR NOTED OTHERWISE ON PLUMBING DRAWINGS.SET AT 120-F. �1`UJ1
<br /> D. TRIM WITH OFFSET TAILPIECE,5/8"ARMAFLEX INSULATION ON EXPOSED HOT WATER AND DRAIN LINES.HOLD ALL EXPOSED PIPING HIGH AS POSSIBLE. FLOW CONTROL VALVE w O
<br /> — VACUUM RELIEF WATTS LFN36-Ml LEAD FREE BRASS BODY.CSA/ANSI Z21.22 E. REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR ACTUAL ROUGH-IN HEIGHT REQUIREMENTS. W Z N
<br /> VALVE F. FURNISH WITH 1/2"X 21/2"STAINLESS STEEL SIMPSON WEDGE-ALL ANCHORS FOR ALL FIXTURES. >W o
<br /> G. CONTRACTOR TO COORDINATE THE REQUIRED CARRIER PRIOR TO ORDERING. IQI PLUG VALVE w W
<br /> — VALVES RED-WHITE 5044AB OR 5049AB LEAD FREE FULL PORT BRASS BALL VALVE WITH PLASTIC JACKETED 0 w LU 0
<br /> APOLLO SERIES 70 LF LEVER TYPE HANDLE. CHECK VALVE (1)
<br /> CRANE LF9210SERIES FLOOR DRAIN SCHEDULE LLI
<br /> WATTS LFFBV-3C OR LFFBA-LF -3C LL PRODUCTS ON THIS SCHEDULE ARE FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR.REFER TO SPECIFICATION '� SHUT-OFF VALVE IN VERTICAL LINE w
<br /> NIBCOWATTS
<br /> FP-600-A-LF
<br /> w
<br /> GENERAL INFORMATION: MARK MANUFACTURER MODEL DESCRIPTION ,-�l BACKFLOW PREVENTER w
<br /> 1. THIS SCHEDULE IS COMPREHENSIVE.ALL MARKS MAY OR MAY NOT BE USED. FD1 SIOUX CHIEF 842 LIGHT DUTY ADJUSTABLE PVC WITH THREADED ADAPTER AND 5"DIAMETER NICKEL BRONZE RING
<br /> JOSAM VEF 400J AND FASTENED GRATE
<br /> OATEY 72000 WATER METER z
<br /> m
<br /> FD3 SIOUX CHIEF 860 LIGHT DUN PVC WITH 9"DIAMETER LOOSE SET PVC HALF GRATE �Y-1 O
<br /> JOSAM FD-3-370 I WHq WATER HAMMER ARRESTOR
<br /> FD4SS JOSAM 3000-S-SS STAINLESS STEEL FLOOR DRAIN,6"X 6"SQUARE TOP,SECURED GRATE
<br /> ZURN ZS415-3NH-6S-P THERMOMETER ISSUE BLOCK
<br /> CLEANOUT SCHEDULE
<br /> ALL PRODUCTS ON THIS SCHEDULE ARE FURNISHED BY OWNER AND INSTALLED B Y CONTRACTOR.REFER TO SPECIFICATIONS. T&P RELIEF VALVE
<br /> MARK MANUFACTURER MODEL DESCRIPTION TMv THERMOSTATIC MIXING VALVE
<br /> WCO ZURN Z1470(Z1469) THREADED,COUNTERSUNK BRONZE OR POLYPROPYLENE CLEANOUT PLUG.(PROVIDE DRILLED
<br /> SIOUX CHIEF 873 TAP FOR CENTER SCREW AND STAINLESS STEEL COVER FOR FINISHED AREAS.) ® FD FLOOR DRAIN
<br /> MIFAB C1430
<br /> JAY R.SMITH 4472T
<br /> JOSAM 58540(58600) $ RD ROOF DRAIN/OVERFLOW ROOF DRAIN
<br /> WATTS CO-590-RD
<br /> WADE 8590(8480R) ® FS FLOOR SINK
<br /> ❑ GENERAL INFORMATION(AS APPLICABLE):
<br /> 1. REFER TO PLANS FOR DRAIN OUTLET SIZE. FCO FLOOR CLEANOUT
<br /> 2. AMSE LOAD CLASSIFICATIONS:LIGHT DUTY<2000 LBS,MEDIUM DUTY 2000-4999 LBS,HEAVY DUTY 5000-7499 LBS,EXTRA HEAVY DUTY 7500-9999 LBS.
<br /> YCO YARD CLEANOUT
<br /> FPWH FREEZE PROOF WALL HYDRANT
<br /> HB HOSE BIBB
<br /> C-II WCO WALL CLEANOUT
<br /> jo CONNECT TO EXISTING CHECKED BY: JEE
<br /> DRAWN BY: RGD
<br /> ETR EXISTING TO REMAIN
<br /> PROTO: 90
<br /> DEMO PIPE
<br /> PROTO CYCLE: 11/11/22
<br /> AREA OF SLAB CUT DOCUMENT DATE: 02/22/23
<br /> —VBF— VENT BELOW FLOOR
<br /> NOT FOR
<br /> CONSTRUCTION
<br /> ALL DRAINS AND CLEANOUTS ON THE INSTALL OPEN HALF
<br /> SALES FLOOR SHALL BE FLUSH WITH OF GRATE UNDER
<br /> THE TOP OF CONCRETE SLAB;DO NOT REFRIGERATED CASE
<br /> SLOPE FLOOR TO THESE DRAINS ACCESS TO CONDENSATE NOTE:IF EXIST FLOOR SLOPES TO NOTE:THIS DETAIL APPLIES ONLY TO
<br /> CASE CONDENSATE DRAIN, DRAIN IS THRU REMOVABLE DRAIN,COORDINATE WITH KEYNOTED RESTROOM FLOOR DRAINS
<br /> END OPEN OVER DRAIN PANEL ON FRONT OF ARCHITECTURAL FOR FLOOR DRAIN AND SHALL NOT BE USED FOR DRAINS
<br /> WITH AIR GAP REFRIGERATED CASE TO BE FLUSH WITH FINISH FLOOR. AND CLEANOUTS ON THE SALES FLOOR.
<br /> REF REFRIGERATION
<br /> REFRIGERATED SET TOP OF DRAIN TO BE FLUSH
<br /> CASE KICKPLATE WITH FINISH CONCRETE OVERLAY.
<br /> SQUARE TOP FLOOR DRAIN COORDINATE FINISH ELEVATION
<br /> FLOOR WITH GENERAL CONTRACTOR.
<br /> DO NOT SLOPE
<br /> ' FLOOR TO DRAIN CONCRETE OVERLAY(TILE WHERE
<br /> ' INDICATED ON ARCHITECTURAL
<br /> FLOOR FINISH PLAN)
<br /> FLOOR
<br /> FLOOR DRAIN BODY WITH 2"OULET
<br /> PIPE INCREASER(IF REQUIRED) FLOOR DRAIN BODY WITH CAULK OR
<br /> PUSH ON OUTLET,�REF NOTE: SZE)MEMBRANE CLAMPI PLANS FOR COLLAR. PLUMBING
<br /> PIPE INCREASER ONLY REQUIR
<br /> CONNECTING WASTE LINE SZEED IF DETAILS AND
<br /> SHOWN ON PLANS IS LARGER THAN
<br /> FLOOR DRAIN OUTLET SIZE SCHEDULES
<br /> DEEP-SEAL P-TRAP
<br /> DEEP-SEAL P-TRAP 4 ;MIN.4"WATER SEAL
<br /> MIN.4"WATER SEAL
<br /> LOCATE FLOOR DRAIN WHERE SHOWN ON DIMENSIONED PLUMBING FLOOR PLAN LOCATE FLOOR DRAIN WHERE SHOWN ON DIMENSIONED PLUMBING FLOOR PLAN.
<br /> REFRIGERATED CASE DRAIN ��OPEN FLOOR AREA DRAIN -RR
<br /> L NTS NTS SHEET:
<br /> P1
<br />
|