Laserfiche WebLink
PB = Pullbox DIF= Determine in Field PB = Pullbox DIF= Determine in Field > >- <br /> JS = Junction Box (N) = New Equipment KES ELECTRICAL JB Junction Box KES ELECTRICAL SCHEDULE m <br /> EC = Electrical Contractor EC = Electrical Contractor <br /> AG # QTY DESCRIPTION VOLT/PH FLA BRK SIZE COND/WIRE PNL/CCT(DIF) RECEP TYPE HGT AFF REQUIREMENTS & REMARKS TAG # QTY DESCRIPTION VOLT/PH FLA BRK SIZE COND/WIRE PNL/CCT(DIF) RECEP TYPE HGT AFF REQUIREMENTS & REMARKS <br /> 9.25E7 1 UTILITY CHASE DIVIDED - BDAP IW - - - - - _ _ CHASE AND RECEPTACLES BY KES, EC TO RUN WIRES AND 8021.01 E2 4 RELOCATED COFFEE BREWER - - - - - - - GC TO DETERMINE& REWORK ALL EXISTING UTILITIES AS RED. <br /> MAKE FINAL CONENECTIONS <br /> CHASE AND RECEPTACLES BY KES, EC TO RUN WIRES AND <br /> 8021.10E2 1 RELOCATED SPECIALTY COFFEE - - - - - - - GC TO DETERMINE & REWORK ALL EXISTING UTILITIES AS REQ. <br /> 2 <br /> 9.26E1 1 UTILITY CHASE DIVIDED - BDAP IW - - - - - - - MAKE FINAL CONENECTIONS 8021.12E2 2 RELOCATED CREAM DISPENSER - - - - - - - GC TO DETERMINE & REWORK ALL EXISTING UTILITIES AS REQ. <br /> 20.00E2 1 AUTOMATED BEVERAGE SYSTEM 120/1 5A 20A 1/2"C-2#12 DIF 5-20R 2'-0' EC TO BRING POWER DOWN WALL, PROVIDE 8021.2OE2 1 RELOCATED BLENDED ICE MACHINE - - - - - - - 0 AIES AS REQ. m <br /> POWER RECEPTACLE 8021.98E2 2 RELOCATED SUGAR DISPENSER - - - - - - - GC TOA U <br /> 20.00E3 1 AUTOMATED BEVERAGE SYSTEM _ _ - - - - - CABLE FURNISHED/INSTALLED BY POS INSTALLER <br /> 8023.07E2 1 RELOCATED COFFEE SERVER STAND - - GC TO DETERMINE& REWORK ALL EXISTING UTILITIES AS REQ. <br /> 20.99E2 1 ABS PRE COOLER 120/1 14,9A 20A 1/2"C-2#12 DIF 5-20R 3'-10" EC TO BRING POWER DOWN WALL, PROVIDE <br /> POWER RECEPTACLE 8024.01 E1 11 1 RELOCATED ORANGE JUICE DISPENSER - - - - - - - GC TO DETERMINE& REWORK ALL EXISTING UTILITIES AS REQ. W� <br /> 39.15E3 1 ICE MACHINE- 1000LB 120/1 1.1A 15A 1/2"C-2#12 OF 5-15R ®CLG CIRCUIT BREAKERS SHALL BE HACR TYPE 8025.02E2 1 RELOCATED ICE TEA BREWER - - - - - - - GC TO DETERMINE& REWORK ALL EXISTING UTILITIES AS REQ. <br /> 41.09E1 1 ICE MACHINE - REMOTE CONDENSER 1000LB 208/3 10.8A 15A 1/2"C-3#12 DIF SEE RMKS - EC TO PROVIDE WP 30A-3P NF DISC AT UNIT ON ROOF- 8116.23E1 2 RELOCATED UNIVERSAL HOLDING CABINET-HD - _ _ - - - GC TO DETERMINE& REWORK ALL EXISTING UTILITIES AS REQ. <br /> CIRCUIT BREAKERS SHALL BE HACR TYPE. 2 SIDED - P&S <br /> 45.24E1 1 BREAKER PANEL- 125 AMP - 1 PHASE - 120_208/1 - 125A 1-1/2"C-3#1 DIF - SEE RMKS 125A/1P BREAKER PANEL TO SUPPLY SERVICE FOR PRINTER 8118.00E1 1 RELOCATED DING OVEN - PIN & SLEEVE - GC TO DETERMINE& REWORK ALL EXISTING UTILITIES AS REQ. rl <br /> EQUIPMENT MOUNTED <br /> ELECTRIC COMMUNICATION UTILITY PLUG INTO ECU CHASE OUTLET <br /> 45.24E2 1 2Qg/1 13.OA 20A - OF - SEE RMKS 8122.26E7 1 RELOCATED HCT TOASTER - PIN & SLEEVE - - - - - - - GC TO DETERMINE& REWORK ALL EXISTING UTILITIES AS REQ. � I <br /> 45.24E4 1 CONVEYOR 208/1 4.9A 20A - OF - SEE RMKS PLUG INTO ECU CHASE OUTLET 8122.27E1 1 RELOCATED HRT TOASTER - PIN & SLEEVE - - - - - - - GC TO DETERMINE& REWORK ALL EXISTING UTILITIES AS REQ. o <br /> 8125.00E1 1 RELOCATED RAPID FILET BUN STEAMER - - - - - - - GC TO DETERMINE& REWORK ALL EXISTING UTILITIES AS REQ. <br /> 117.30E1 i UHC TABLE - 2 SIDED FOR OPL - 51" - 120/1 2.OA 20A SEE RMKS DIF SEE RMKS - PLUGS INTO OVERHEAD RECEPTACLE#33006W(B) PROVIDED <br /> PIN & SLEEVE BY KES-HEIGHT TO BOTTOM OF RECEPTACLE. 8181.01 E2 1 RELOCATED REFRIGERATOR-SPECIALTY COFFEE - - - - - - - GC TO DETERMINE & REWORK ALL EXISTING UTILITIES AS REQ. <br /> Professional of Record: <br /> 123.4OE2 1 PREP TABLE (2 SIDED COPL) 83"W-REF 120/1 7.OA 20A - DIF - - PLUGS INTO RACEWAY- POWERED BY BREAKER PANEL 8203.02E1 1 RELOCATED HEAT TREAT COMBINATION - _ _ _ _ _ - GC TO DETERMINE& REWORK ALL EXISTING UTILITIES AS REQ. <br /> SHAKE SUNDAE MACHINE <br /> 125.00E2 2 RAPID FILET BUN STEAMER 208/1 14.3A 30A 1/2"C-2#10 DIF - - PLUGS INTO ECU ELECT. PANEL 8205.11 E2 1 RELOCATED FROZEN CARBONATED BEVERAGE - _ _ _ _ _ - GC TO DETERMINE& REWORK ALL EXISTING UTILITIES AS REQ. <br /> 130.00E3 1 COMBI OVEN 208/3 15.1A 30A 1/2"C-3#10 OF - - EC TO EXTEND CIRCUIT TO L43OR9 RECEPTACLE 8207.00E1 1 RELOCATED BLENDER - MCFLURRY - - - - - - - - GC TO DETERMINE& REWORK ALL EXISTING UTILITIES AS REQ. <br /> COUNTERTOP PM <br /> 178.13E1 t REACH-IN REFERIGERATOR - SINGLE WIDE 120/1 11.3A 20A 1/2"C-2#12 DIF 5-20R 7'-6" EC TO BRING POWER DOWN WALL, PROVIDE 8215.98E1 2 RELOCATED POS - PC HARDWARE - - - - - - - GC TO DETERMINE& REWORK ALL EXISTING UTILITIES AS REQ. DESIGN <br /> POWER/RECEPTACLE 8215.98E2 2 RELOCATED POS - PC HARDWARE - - - - - - - GC TO DETERMINE& REWORK ALL EXISTING UTILITIES AS REQ. Architectural <br /> 183.02E2 1 REFRIGERATOR - 2 DRAWER 120/1 5.OA 20A 1/2"C-2#12 DIF 5-20R - EC TO EXTEND CIRCUIT TO 5-20R RECEPTACLE IN CHASE 8216.00E2 9 RELOCATED POS -VIDEO MONITOR - - - - - - GC TO DETERMINE& REWORK ALL EXISTING UTILITIES AS REQ. Solutions Group <br /> 207.11 E1 2 BASE REFRIGERATOR 120/1 3.2A 20A 1/2"C-2#12 DIF 5-20R 2'-0" EC TO BRING POWER DOWN WALL, PROVIDE 8216.00E3 2 RELOCATED POS -VIDEO MONITOR - - - - - - - GC TO DETERMINE& REWORK ALL EXISTING UTILITIES AS REQ. 1940140TH AVEW <br /> POWER/RECEPTACLE SUITE 420 <br /> 207.11 E4 1 BASE REFRIGERATOR 120/1 3.2A 20A 1/2"C-2#12 DIF 5-20R 6'-0" PLUGS INTO OVERHEAD RECEPTACLE W(Y) PROVIDED 8216.00E7 6 RELOCATED POS - VIDEO MONITOR 0 CHASE - - - - - - - GC TO DETERMINE& REWORK ALL EXISTING UTILITIES AS REQ. LYNNWOOD,WA 98036 <br /> _ _ <br /> BY KES-HEIGHT TO BOTTOM OF RECEPTACLE. <br /> _. 8217.00E1 3 RELOCATED PARK/ROTATE/SERVE BUMP BAR - - - - GC TO DETERMINE& REWORK ALL EXISTING UTILITIES AS RED. .tunes(425) ,v.e. <br /> PHON8219.00E3 3 RELOCATED POS - RECEIPT PRIMER - - - - - - - GC TO DETERMINE & REWORK ALL EXISTING UTILITIES AS REQ. L:JY lazsleaysass <br /> 11.00E6 1 DELIVERY TABLETS 120/1 3A 20A 1/2"C-2#12 DIF (2) 5-20R 5'-6" - enud weAnnnmvMociwc.coM <br /> 8219.00E4 3 RELOCATED POS - RECEIPT PRINTER - - - - - - - GC TO DETERMINE & REWORK ALL EXISTING UTILITIES AS REQ. <br /> 15.00E15 - POS REGISTER - FRONT COUNTER - - - 2"C OF PB 10 - 8219.00E7 1 RELOCATED POS - RECEIPT PRINTER - - - - - - GC TO DETERMINE & REWORK ALL EXISTING UTILITIES AS REQ. <br /> 15.07E1 1 POS REGISTER - DELIVERY 120/1 IG 3A 20A 1/2"C-2#12 DIF IG4700 3'-6" EC TO PROVIDE/INSTALL RECEPTACLE, POS INSTALLER TO 8219.00E8 1 RELOCATED POS - RECEIPT PRINTER - - - - - - - GC TO DETERMINE & REWORK ALL EXISTING UTILITIES AS REQ. <br /> CONN. POS 8237.00E2 1 RELOCATED PIE DISPLAY - - - - - - GC TO DETERMINE& REWORK ALL EXISTING UTILITIES AS REQ. <br /> 15.07E3 1 POS REGISTER - DELIVERY - - DIF 4X4X4 PB 3'-6" EXTEND 2"CONDUIT ABOVE CEILING FOR POS DATA CABLES <br /> 216.00E1 1 POS - VIDEO MONITOR 120/1 IG 1/2"C-2#121G OF IG4700 - EC TO PROVIDE/INSTALL RECEPTACLE, POS INSTALLER TO NOTE: EQUIPMENT SCHEDULE ABOVE IS FOR REFERENCE ONLY. EC TO FIELD DETERMINE ALL COMPONENTS ABOVE ARE INSTALLED AND IF NOT, PROVIDE PROVISIONS WITHIN SCOPE OF WORK TO DO SO. EC TO PROVIDE <br /> CONN. POS ALL POWER AND DATA REQUIREMENTS TO ENSURE A COMPLETE AND OPERATIONAL ELECTRICAL SYSTEM. DETERMINE ALL ROUGH-IN LOCATIONS WITH ACM AND MANUFACTURER'S SPECIFICATIONS PRIOR TO ROUGH-INS. <br /> 216.00E2 3 POS - VIDEO MONITOR - - DIF - - CABLE FURNISHED/INSTALLED BY POS INSTALLER <br /> 16.00E3 1 POS - VIDEO MONITOR W/SUPPORTS 120/1 IG 1.5A - 1/2"C-2#121G DIF IG4700 ®CLG EC TO PROVIDE/INSTALL RECEPTACLE, POS INSTALLER TO PER 2023 NEC 210.8(B): ALL SINGLE-PHASE p0000O0 <br /> CONN. POS RECEPTACLES 150V TO GROUND OR LESS, 50Yg°�oo <br /> AMPS OR LESS AND THREE-PHASE RECEPTACLES <br /> 16.00E7 1 POS - VIDEO MONITOR W/SUPPORTS & CHASE 120/1 IG 1.5A SEE RMKS 1/2"C-2#121G DIF _ SEE RMK EC TO BRING POWER DOWN CHASE AND CONNECT OT CHASE RATED 150V TO GROUND OR LESS, 100 AMPS OR CONFIRM QUANTITIES AND LOCATIONS WITH 00OFW�htiq'A 000 <br /> MOUNTED RECEPTACLE LESS INSTALLED WITHIN KITCHEN, BATHROOMS, GENERAL. FURNISH AND INSTALL ISOLATED o <br /> 16.00E11 1 POS-VIDEO MONITOR 120/1 IG 1.5A 20A 1/2"C-2#121G DIF IG4700 5'-6" EC TO PROVIDE/INSTALL RECEPTACLE, POS INSTALLER TO ROOFTOPS, OUTDOORS, SINKS, INDOOR WET CIRCUITS FOR EACH DEVICE PER DUAL POINT C=?� <br /> CONN. POS <br /> LOCATIONS SHALL HAVE GFCI PROTECTION FOR SYSTEM ELECTRICAL SCHEDULE. FURNISH AND <br /> 1 s.00E12 1 POS-VIDEO MONITOR _ _ _ _ plp 4X4X4 PB 5'-6" EXTEND 2"CONDUIT ABOVE CEILING. CABLE FURNISHED BY PERSONNEL. GFCI PROTECTION MAY BE PROVIDED INSTALL ADDITIONAL BREAKERS, FEEDERS, 00 'pFCISTE „ Q <br /> POS SYSTEM SUPPLIER. PANELS, AND MISCELLANEOUS AS NEEDED. 0p G <br /> 17.00E1 7 PARK ROTATE/SERVE BUMP BAR - - - - OF - - POS TO COORD W/MCD 0/0, RELOCATE EXIST AS REQUIRED AT THE RECEPTACLE IF READILY ACCESSIBLE, CONFIRM WITH VENDOR WHICH CIRCUITS REQUIRE `a''�C4VAL '�000 k <br /> / OTHERWISE, MUST BE PROVIDED AT THE PANEL DEDICATED CIRCUITS. Op000O000 �,��2 <br /> 219.00E3 1 POS - RECEIPT PRINTER 120/1 ISO 0.7A 20A 1/2"C-2#121G DIF IG4700 ®CLG - BREAKER. Sea! <br /> 219.o0E4 1 POS - RECEIPT PRINTER _ _ _ DIF 4X4X4 PB ®CLG - EC TO EXTEND EXISTING CONDUIT/CONDUCTOR AS MODULAR COUNTER LAYOUT, CONFIRM LAYOUT <br /> APPLICABLE FOR ALL RELOCATED RECEPTACLES TO WITH MCD CONSTRUCTION SUPERVISOR AND REFER TO <br /> -d <br /> 219.00E7 2 POS - RECEIPT PRINTER - - NEW LOCATION PER LATEST DECOR DRAWINGS. EC TO DETAILS ON SHEET E1.3 FOR MORE "O� <br /> 120 1 ISO 0.7A 20A 2"C-2 121G DIF IG4700 � z� ° L <br /> ; a`o 'o <br /> 219.00E8 2 POS - RECEIPT PRINTER _ _ _ - DIF - - CABLE FURNISHED/INSTALL INFORMATION. <br /> ED BY POS INSTALLER SHALL REMOVE ANY UN-USED u`5 U `o° Y°� <br /> ONDUIT/CONDUCTOR FOR ALL DEMO RECEPTACLES ' J 8o <br /> 219.05E3 1 STICKY LABEL PRINTER 120/1 ISO 0.7A 20A 1/2"C-2#121G DIF IG4700 3'-2" - _ J `0 89 ,m 2 <br /> ELECTRICAL CONTRACTOR TO DETERMINE ALL <br /> 700.24E1 1 ECONOMY OEP BOX W/MOUNTING HARDWARE - - - - OF - - CEILING MOUNTED (2 TWISTLOCK RECEPTACLES HSL IG4700 SCOPE OF WORK WITH ACM AND/OR GENERAL <br /> REQ) CONTRACTOR PRIOR TO BID. Q at c.n <br /> NOTE: EQUIPMENT SCHEDULE ABOVE IS FOR REFERENCE ONLY. EC TO FIELD DETERMINE ALL COMPONENTS ABOVE ARE INSTALLED AND IF NOT, PROVIDE PROVISIONS WITHIN SCOPE OF WORK TO DO SO. EC TO PROVIDE <br /> ALL POWER AND DATA REQUIREMENTS TO ENSURE A COMPLETE AND OPERATIONAL ELECTRICAL SYSTEM. DETERMINE ALL ROUGH-IN LOCATIONS WITH ACM AND MANUFACTURER'S SPECIFICATIONS PRIOR TO ROUGH-INS. - - - - - - - _ D °°-V <br /> 025.0 E2 1 N « Oo <br /> ELECTRICAL SCOPE 219.0 E7 021 1 E2 <br /> OF WORK <br /> o°°z" <br /> 215.9 E1 216.0 E7 � °m "'m <br /> ®KEYED NOTES <br /> ' d - <br /> 1. RELOCATED CONNECTION FOR NEW POS REGISTER - FRONT COUNTER. EC TO RELOCATE/EXTEND EXISTING CONDUIT/CONDUCTORS 130.00 E3 219.00 E3 215 9 E2 16.00 E7 023.0 E2 m .�o°°m c <br /> 024.01 E1 021.01 E2 <br /> y AS NECESSARY. FIELD DETERMINE FINAL LOCATION AND REQUIREMENTS PRIOR TO INSTALLATION. _ / 217.00 E4 237.0 E2 <br /> 17.00 E1 16.00 E2 217.00 E1 9:26 E1 A a 66 >P-m <br /> 2. RACEWAY PROVIDED WITH COUNTER, INSTALLED BY E.C, SEE SHEET E1.3. -� ! 219i0 E3 16.00 E, 216.0 E2 216.0 E7 I °t°° E <br /> i 122.2 E1 00.24 E1 219.0 E4 c°«nm° <br /> 205.11 E2 181.01 E2 °S°e.'.n S <br /> $ 3. EC TO PROVIDE 20A/1P BRANCH CIRCUIT BREAKER AND 1/2"C,2#12,IG, 5-20R RECEPTACLE FOR FUTURE DELIVERY TABLET. i 118.0 E1 207.11 E4 217.0 E1 203.0 E1 022b E2 021.1 E2 I CC� a�==3aay <br /> 207.0 Et 9.25 E1 o <br /> a RECEPTACLE SHALL BE MOUNTED AT 3'-4"AFF. - - <br /> J J o v�•..m"oo= <br /> 4. EC TO PROVIDE 1/2"C, 2#12 IG POWER FEED TO DIGITAL MERCHANDISER. FIELD DETERMINE WITH ACM AND MANUFACTURE'S 216.0 E2 2 °g '6. <br /> SPECIFICATIONS FOR EXACT LOCATION PRIOR TO ROUGH-IN AND INSTALLATION. -� 216.0 E3 1 4 �m5 <br /> N 217.0 E1 700.0 E1 M <br /> 4 E1 a <br /> a 5. RELOCATED CONNECTION FOR (E) SELF ORDER KIOSK WITH RELOCATED POWER AND DATA W/ TRIM PLACE. EC TO 219.0 Ea 117.30 E1 4 E2 215.00 E15 I k <br /> 116.2 E1 4 E4 <br /> RELOCATE/EXTEND EXISTING CONDUIT/CONDUCTOR AS NECCESARY. FIELD DETERMINE FINAL LOCATION AND REQUIREMENTS PRIOR E3 .0 E2 �TO INSTALL. -- - - 0[ 0 E7, : ES 17.00 E1 1600 E2 <br /> 16.00 E3 19 00 <br /> y 6. PROVIDE POWER AND DATA ROUGH-INS FOR CASH HANDLERS. REFER TO 2/E1.3 FOR MORE INFORMATION. COORDINATE EXACT _ 1 -- _ - - - - - - <br /> LOCATION WITH DECOR DRAWINGS. <br /> j <br /> 183.02 E2 <br /> 0 <br /> U <br /> p <br /> 20.00 E2 ill620.99 E2 <br /> 20.00 E3 i 3915 E3 <br /> . 19.05 E3 N <br /> 16.00 E11 <br /> b ! 17.00 E1 _ 3 <br /> v� Z Q <br /> N <br /> Ld <br /> _j LLi <br /> O Of m <br /> ZO - O Q o <br /> / 1 \ELECTRICAL ROUGH-IN PLAN N <br /> E1.1 3 16 11'-0" g <br /> E ® U <br /> °�. `^ ELEC ROUGH IN PLAN <br />