My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2600 FEDERAL AVE 2021 PORT OF EVERETT 2025-09-29
>
Address Records
>
FEDERAL AVE
>
2600
>
PORT OF EVERETT
>
2600 FEDERAL AVE 2021 PORT OF EVERETT 2025-09-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2025 11:38:10 AM
Creation date
9/5/2025 12:01:45 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
2600
Tenant Name
PORT OF EVERETT
Year
2021
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
448
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DESIGN AND CONSTRUCTION STANDARDS AND SPECIFICATIONS <br /> Pump(s)do not turn on or Trip floats check for Floats/Sensors function <br /> shutoff when water levels proper electrical action, as designed. <br /> reach design levels. replace floats if not <br /> functioning <br /> Rails(if Pump cannot be readily Dismount top rail mounts Rails repaired or <br /> present) raised from the wetwell due remove pump and rails, replaced so that pump <br /> to bent,corroded or inspect clean or replace can be removed with a <br /> otherwise non-functional rails. reasonable amount of <br /> rails. <br /> effort. <br /> Pump cannot be removed Clean and inspect rails Pump can be easily <br /> from disconnect flange or and piping,dislodge separated from flange <br /> is difficult to disconnect flange to pump discharge by <br /> from flange. piping <br /> lifting from above the <br /> wetwell. <br /> Pump does not re-connect to Clean and inspect mating Pump slides easily <br /> disconnect flange or leaks at surfaces and replace seal back into connection <br /> flange after being if damaged, when lowered into <br /> pulled. check rails for bending place and <br /> does not leak at flange. <br /> Panel No power to control panel Verify power from PUD, Power is restored to <br /> malfunction or portions thereof. fuses and disconnects entire panel. <br /> Error message or warning Issues identified and <br /> lights. resolved in accordance <br /> Consult O&M manual with operations manual <br /> Control from panel manufacturer and manufacturer's <br /> recommended <br /> Panel procedures. <br /> Pump(s)do no cycle Check for power and System checked and <br /> through on/off conditions control wiring via O&M functioning as <br /> when wetwell is filled. manual designed. <br /> Enclosure Enclosure is broken of Enclosure should have no Enclosure repaired. <br /> damage otherwise damaged to the moisture inside or <br /> extent that rainwater or exposed openings repair <br /> debris can enter. or replace as needed <br /> No.26—Private Stormwater Pumps(Continued) <br /> Pump(Cont.) Alarms Physical damage to O&M manual should Alarms are repaired <br /> auditory or visual alarms,or have instructions to test and operate as <br /> alarms are missing. alert systems. designed. <br /> Alarms don't trigger when Check float switch and Alarms are triggered at <br /> wetwell filled past max wiring,lights or buzzers, design water surface <br /> water or drained below repair/replace faulty levels. <br /> minimum water level. components. <br /> Telemetry system(where Telemetry system fully <br /> present)not communicating Consult O&M manual functional and sending <br /> with appropriate from panel manufacturer desired information to <br /> recipient(s). appropriate <br /> reci ient s . <br /> STORM AND SURFACE WATER 4-38 <br />
The URL can be used to link to this page
Your browser does not support the video tag.