Laserfiche WebLink
T • •Mobile - <br /> FROM DIN <br /> DISTRIBUTION <br /> PLANS PREPARED BY: <br /> CCOPINEPl3TONE <br /> DAC(COOLING)CONTROLLER 16928 WOODINVILLE-REDMOND RD NE,SUITE 210 <br /> WOODINVILLE,WA 98072 <br /> PHONE:425+487.1732 <br /> RED RED + WWW.CORNERSTONE-ENGR.COM <br /> COHN FUNCTION LIGHT ASSEMBLY <br /> FROM DC DIN JI PIWR IN BLK BLK PROJECT INFO: <br /> DISTRIBUTION J8 DELTA T JUMPER SE01510A <br /> J1 Q TO CABINET J9 OUTSIDE TEMPETATURE LIGHT <br /> �sw1 � COOL ALARM BLOCK SWITCH DOWNTOWN EVERETT-WALL <br /> J7 DACFAN LOWER BLK � <br /> J6 DACFAN (UPPER) BLK NC 2930 WETMORE AVENUE <br /> ® J3 ALARM EVERETT,WA 98201 <br /> TO HEAT RED "° <br /> J8 J9 J7 IJ J8 J3 J2 COOLING INHBIT N SNOHOMISH COUNTY <br /> O ® O CONTROLLER BLK <br /> J4 HEAT REQUEST ISSUED FOR: <br /> HEATER DOOR OPEN C CONSTRUCTION <br /> COOLJ9 J8 DETECT L <br /> FROM J7 ALARM <br /> DAC REV:-DATE:—ISSUED FOR: BY: <br /> DOOR ALARM <br /> HEATER CONTROLLER Q 09-25-20 CLIENT COMMENTS DRA <br /> 07-10-zo FINAL DMo <br /> FROM DC DIN COHN FUNCTION Qo <br /> DISTRIBUTION JI PIWR IN <br /> g 06-01-20 REVISED TO ANCHOR JRF <br /> J1 J8 HEAT REQUEST q 05-04-20 PRELIMINARY JRF <br /> O SKU# 33965 - DC CABINET DOOR LIGHT POWER WIRING DIAGRAM <br /> J9 COOLING INHBIT 3 <br /> �sw1 -cb HEAT J7 UNUSED 22x34 SCALE:NTS 11x17 SCALE:NTS DRAWN BY:=CHK.: APV.: <br /> L JRF MWO MWO <br /> J6 HEATER FAN CURRENT ISSUE DATE: <br /> ® J3 ALARM � � r <br /> J8 J9 J7 J8 J3 J2 a J L 09-25-20 <br /> O ® O J2 DOOR SW INPUT p OJ LICENSURE: <br /> J4 HEATER REALY CONTROL I- <br /> z <br /> x LD O O Q� °SAS o <br /> Door Open W W ED J � <br /> FROM a � mQ O <br /> Detect ? p v O w <br /> DOOR RE PO�FSFG'sTF °a�� s-2s-2o2o <br /> TO LED LIGHT S/ONAL E <br /> RED oo BLACK BLACK <br /> B 0000000 <br /> JURISDICTIONAL APPROVAL: <br /> 0 0 0 000 000 <br /> O < < as O <br /> TO HEATER BLACK RED B 0 0 0 0 000 <br /> ELEMENT Gee <br /> ACPWR BLACK <br /> FROM CIRCUI RED V+ V-48 <br /> BREAKER TO DOOR BLACK FROM PROPRIETARY INFORMATION: <br /> RED <br /> V+ DC PLANT DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY <br /> UPPER FAN V- BLK RED 2 ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY <br /> ERRORS AND OMISSIONS.ALL PREVIOUS ISSUES OF THIS <br /> TO DOOR V+ RE DRAWING ARE SUPERSEDED BY THE LATEST REVISION. <br /> IN THE FORMATION CONTAINED IN THIS SET OF DOCUMENTS <br /> BLK IS PROPRIETARY BY NATURE.ANY USE OR DISCLOSURE <br /> LOWER FAN V_ OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS <br /> STRICTLY PROHIBITED. <br /> DC DISTRIBUTION (BLACK WIRE JUMPERS TO DRAWING TITLE: <br /> FUSE POSOTIONS REMOVED FOR CLARITY) ELECTRICAL DIAGRAMS <br /> DRAWING NUMBER: <br /> E-1 .2 1 <br /> SKU# 33965 - DC HEATING AND COOLING WIRING DIAGRAM 2 SKU# 33965 - DC FUSE BLOCK WIRING DIAGRAM <br /> CEI JOB NUMBER: L600/ANCHOR 20-06014 <br /> 2204 SCALE:NTS 111x17 SCALE:NTS 22x34 SCALE:NTS 111x17 SCALE:NTS <br />