Laserfiche WebLink
GENERAL <br /> (E)"Z"PURLIN CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND <br /> TEMPORARY BRACING AS NECESSARY UNTIL PERMANENT SUPPORT AND <br /> STIFFENERS ARE SAFELY INSTALLED. <br /> #10S.D.S.@ T • •Mobile- <br /> + ® <br /> 2"O.C.STAGGERED DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. <br /> n n T <br /> WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED,BUT ARE OF A <br /> (3)#10 S,D,S @ Y Y SIMILAR CHARACTER TO DETAILS SHOWN,SIMILAR DETAILS OF <br /> -—+ + + + + CONSTRUCTION SHALL BE USED,SUBJECT TO REVIEW AND APPROVAL BY <br /> JOINT ENDS <br /> I I THE ENGINEER. <br /> 1„ PLANS PREPARED BY: <br /> ADD(2)RAMSET I STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH <br /> (PIN#SP58TH) ARCHITECTURAL AND ELECTRICAL DRAWINGS FOR BIDDING AND <br /> + + + + + + + XT ( <br /> @ 54 END CONSTRUCTION. Cp��sTp� <br /> (E)PENTHOUSE Ca-_* <br /> -- --------- ------------ -- CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS,ELEVATIONS AND <br /> DETAILS PRIOR TO FABRICATION OR CONSTRUCTION. 16928 WOODINVILLE-REDMOND RD NE,SUITE 210 <br /> 2" 4" WOODINVILLE,WA 98072 <br /> MIN 4 T CODE PHONE:425.487.1732 <br /> (E)END WALL I I I I I I WWW.CORNERSTONE-ENGR.COM <br /> (E)GIRDER BENT OR I I ALL MATERIALS,WORKMANSHIP,DESIGN AND CONSTRUCTION SHALL <br /> END WALL FRAME I I I I I I CONFORM TO THE DRAWINGS AND THE INTERNATIONAL BUILDING CODE(IBC), <br /> 2015 EDITION.STANDARDS WHERE REFERENCED ON THE DRAWINGS SHALL PROJECT INFO: <br /> (E)ANTENNA TRIPOD BE THE LATEST EDITION. <br /> -- ------------ ------ SE01510A <br /> DESIGN LOADS <br /> RISK CATEGORY=II <br /> - (E)BENT GIRDER WIND LOAD:(OTHER STRUCTURE) DOWNTOWN EVERETT-WALL <br /> V.I.F. BASIC WIND SPEED=110 MPH(3-SECOND GUST) <br /> EXPOSURE"B" <br /> IMPORTANCE FACTOR =1.0 2930 WETMORE AVENUE <br /> JOIST END CONNECTION DETAIL TOPOGRAPHIC FACTOR=1.0 EVERETT,WA 98201 <br /> 1 1 1 / SEISMIC LOAD:(COMPONENTS) SNOHOMISH COUNTY <br /> 22x34 SCALE:NTS 111x17 SCALE:NTS I 1 7==�1 <br /> I I � I I I I I I S"s=0.880g,&,=0.502g <br /> I I aP=1.0,RP=2.5,Q.=2.5 ISSUED FOR: <br /> SITE CLASS"D"(ASSUMED) r <br /> (E)MTL ROOF (E)"Z"PURLIN IMPORTANCE FACTOR=1.0 L PERMIT <br /> o d O SEISMIC DESIGN CATEGORY"D" <br /> 9 - REV::DATE:=ISSUED FOR: BY: <br /> o l COLD-FORMED STEEL FRAMING <br /> THE MEMBERS(Fy=50ksi)SHALL HAVE THE MINIMUM SECTION PROPERTIES <br /> I SHOWN BELOW <br /> MEMBER DEPTH(IN) GAUGE S(IN3) I(IN4) <br /> I I I Z I STUD 6.0 12 2.165 6.496 <br /> + + + + + + + + + I I I I I zi I (600S250-97) Q 09-23-20 PERMIT DRA <br /> � I I I I I I I I I dl I <br /> (E)MECHANICAL Ni ERECT FRAMING IN ACCORDANCE WITH MANUFACTURER'S <br /> - RECOMMENDATIONS. WELDS SHALL CONFORM TO AWS D1.3"STRUCTURAL 0 08-25-20 PERMIT LJS <br /> LOUVERED VENT E BENT GIRDER W <br /> ( ) I WELDING CODE SHEET STEEL",OR SECTION E2 OF THE AISI CODE. SCREWS <br /> Ll+ + + + + + + 2� DRAWN BY:—CHK.: APV.: <br /> I I I I I I I I SHALL BE HEX HEAD,SELF TAPPING TYPE,#8 OR HEAVIER,U.N.O.. <br /> LJS RKN JDG <br /> DRAWING NOTES <br /> 3 CURRENT ISSUE DATE: <br /> ALL EXISTING CONDITIONS AND EQUIPMENT ARE NOT SHOWN.CAREFUL <br /> 1^ TYP (E)ACCESS COORDINATION WITH EXISTING STRUCTURE AND EQUIPMENT IN REQUIRED. 09-23-20 <br /> #10S.D.S.@ L LADDER <br /> 11 <br /> 2"O.C.STAGGERED ADD'L 60OS250-97 SEE ARCHITECTURAL DRAWINGS FOR OVERALL SITE PLAN AND LOCATIONS. LICENSURE: <br /> (E)MTL CEILING I I � I (E)ANTENNA TRIPOD I I I I I <br /> � <br /> V.I.F.LOCATIONS I ��� I I I I I I I I of WA <br /> REMOVE& <br /> REPLACE q O <br /> rypNZ <br /> WHEREREQ'D a0 - 1 = I46939 <br /> 01 <br /> JOIST UPGRADE ELEVATION 4 \ (E)ANTENNATRIPOD <br /> 0 1 /j I PROVIDE UPGRADE OF Ssiq qL Eck c}Z'�$020 <br /> 22x34 SCALE:3/4"=1'-0" 11x17 SCALE:3/8"=1'-0" \� E BRACE <br /> .61 O (E)BRACE (2)60OS250-97 TYP OF <br /> -I - -I EA"Z"PURLIN ENGAGED <br /> E MTL ROOF (E)"Z PURLIN I % * BY(E)TRIPODS JURISDICTIONAL APPROVAL: <br /> O V.I.F.EXACT LOCATIONS // gam <br /> --Q/ <br /> ADD'L 60OS250-97 4 <br /> I I I I I I I I I I <br /> - OPP HAND I I I I I I I I I I I I <br /> I (E)END WALL I <br /> I I <br /> L-------- -----------------------------------------1 <br /> (E)VENT(TYP) PROPRIETARY INFORMATION: <br /> DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY <br /> ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY <br /> ERRORS AND OMISSIONS.ALL PREVIOUS ISSUES OF THIS <br /> DRAWING ARE SUPERSEDED BY THE LATEST REVISION. <br /> THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS <br /> IS PROPRIETARY BY NATURE.ANY USE OR DISCLOSURE <br /> OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS <br /> STRICTLY PROHIBITED. <br /> NOTE; DRAWING TITLE: <br /> J 1. CONTRACTOR SHALL FIELD VERIFY ALL FIELD CONDITIONS& STRUCTURAL NOTES, <br /> NOTIFY ENGINEER OF RECORD OF AND DISCREPANCIES OR <br /> #10 S.D.S.@ ALTERATIONS. PLAN&DETAILS <br /> 2"O.C.STAGGERED 2. CONTRACTOR SHALL VERIFY ANCHORAGE OF TRIPOD IS DRAWING NUMBER: <br /> CENTERED ON TOP FLANGE OF Z-PURLIN.NOTIFY ENGINEER OF <br /> ADD'L 60OS250-97 RECORD OF AND DISCREPANCIES OR ALTERATIONS. <br /> PLAN NORTH 1 � 1 1 <br /> JOIST UPGRADE SECTION 3 ROOF PLAN RT STRUCTURAL NOTES CEI JOB NUMBER: L600/ANCHOR 20-06014 <br /> 22x34 SCALE:1 1/2"=1'-01, 11x17 SCALE:3/4"=V-0" 22x34 SCALE:1/8"=V-0" 11x17 SCALE:1/16"=V-0" 22x34 SCALE:NTS 11x17 SCALE:NTS <br />