SYSTEM DESIGNATIONS EQUIPMENT/DEVICES RECEPTACLES ABBREVIATIONS GENERAL NOTES <br /> N'S <br /> HMARKS INDICATETHE QUANTITYOF CONDUCTORS $ SINGLE POLE TOGGLE SWITCH DUPLEX,15A,120V,l0,2P,3W, PARALLEL BLADE, GROUNDED. A. AMPERES A. ELECTRICAL LAYOUT DRAWINGS ARE PARTIALLY DIAGRAMMATIC. REFER <br /> #12WREUNLESSOTERWISENOTED). IF UNMARKED AC ALTERNATING CURRENT TO ARCHITECTURAL,STRUCTURAL, MECHANICAL AND HVAC DRAWINGS FOR <br /> STALL 2#12 IN 1/2 ND $3 THREE-WAY TOGGLE SWITCH FOUR PLEX-2 DUPLEX 15A,10,2P,3W, PARALLEL BLADE GROUNDED. GUIDANCE ON DIMENSIONS, CEILING HEIGHTS, DOOR SWINGS, ROOM FINISHES, <br /> PHASE CONDUCTORS $K KEY SWITCH 30 SINGLE, 30A, 480V, 30, 4 POLE, WITH A.F.F. ABOVE FINISHED FLOOR STRUCTURAL AND ARCHITECTURAL DETAILS, LOCATIONS OF DUCTS, PIPES AND <br /> NEUTRAL CoNDUCTOR(IF REQUIRED) BACK BOX, GROUND THRU EXTRA POLE AND SHELL. ATS AUTOMATIC TRANSFER SWITCH STRUCTURAL STEEL. INSTALL THE ELECTRICAL SYSTEMS WITHOUT INTERFERING <br /> GROUND CoNDUCTOR(IF REQUIRED) $LV SWITCH FOR LOW-VOLTAGE SWITCHING SYSTEM 20 AWG AMERICAN WIRE GAUGE WITH DUCTS, PIPES, STRUCTURAL STEEL OR OTHER SYSTEMS. LOCATE LIGHTING <br /> 3V34-iV-6A/7,9,11 INDICATES THE NUMBER OF LOW VOLTAGE SWITCHES 9 DUPLEX,20A,120V,10,2P,3W, PARALLEL BLADE, GROUNDED B.O.D. BOTTOM OF DUCT SYMMETRICALLY IN PROPER RELATION TO FINISHED AREAS EXCEPT WHERE <br /> 3/4"c,3N8 PANEL HOME-RUN $Lv(z)PANEL/CIRCUIT AS NOTED ON DRAWING. (EG. (2) INDICATES TWO Ic DUPLEX 15A 120V 10 2P 3W PARALLEL BLADE B.O.T. BOTTOM OF TRAY DIMENSIONED ON THE DRAWINGS OR LOCATED ON REFLECTED CEILING PLANS. <br /> CONDUIT/CONDUCTORS SWITCHES AT THIS LOCATION) WITH ISOLATED GROUND, ORANGE CAT. NO. CATALOGUE NUMBER B. PROVIDE ADDITIONAL SUPPORTS FOR SWITCHES, STARTERS, RACEWAYS AND <br /> OTHER ELECTRICAL EQUIPMENT WHERE THE BUILDING STRUCTURE IS NOT <br /> CONDUIT RUN EXPOSED, ALL CONDUITS 1/2" UNLESS $OC LIGHTING SWITCH WITH OCCUPANCY SENSOR #20 FOUR PLEX-2 DUPLEX, 20A,10,2P,3W, PARALLEL BLADE GROUNDED. CKT. CIRCUIT SUITABLE FOR DIRECT MOUNTING. <br /> OTHERWISE REQUIRED OR NOTED zo CND. CONDUIT <br /> $y MOTOR RATED SWITCH, 120V, 15A, 10 SINGLE, 20A, 120V, 10, 2P, 3W, STRAIGHT BLADE, GROUNDED C. A NUMERAL BESIDE A BRANCH CIRCUIT OUTLET ON WIRING PLANS INDICATES <br /> ------- CONDUIT RUN CONCEALED IN WALLS, ABOVE CEILING, IN 30 CONT. CONTINUATION PANELBOARD BRANCH CIRCUIT CONNECTION. A LOWER CASE LETTER BESIDE AN <br /> FLOOR SLAB OR UNDERGROUND C] PUSHBUTTON STATION SINGLE, 30A, 120V, 10, 2P, 3W, STRAIGHT BLADE, GROUNDED DC DIRECT CURRENT OUTLET INDICATES THE SWITCH LEG CONNECTION WHERE OUTLETS ARE LOCALLY <br /> -T- TELEPHONE, 3/4" MINIMUM CONDUIT ONLY, UNLESS M MANUAL MOTOR STARTER WITH OVERLOADS AND l30 SINGLE, 30A, 208V, 10, 2P, 3W, STRAIGHT BLADE, GROUNDED DISC DISCONNECT SWITCHED. <br /> SIZED OTHERWISE PILOT LIGHT @20 SINGLE, 20A, 120/208V, 10, 3P, 4W, POLARIZED, DPST DOUBLE POLE SINGLE THROW D. SYMBOLS IN THE LEGENDS ARE APPLICABLE GENERALLY. FOR EXACT <br /> -e- EMERGENCY CIRCUIT IS MAGNETIC MOTOR STARTER DWG. DRAWING <br /> STRAIGHT BLADE, GROUNDED REQUIREMENTS REFER TO THE SCHEDULES, LAYOUTS, DETAILS AND <br /> 60 SINGLE, 60A, 120/208V, 10, 3P, 4W, POLARIZED, EL. ELEVATION SPECIFICATIONS. <br /> -PA- PAGING CONDUIT WITH WIRE AS NOTED COMBINATION STARTER, CIRCUIT BREAKER TYPE, STRAIGHT BLADE, GROUNDED ELEC. ELECTRICAL/ELECTRIC E. PROVIDE SEAL FITTINGS IN CONDUITS THAT ENTER HAZARDOUS AREA FROM <br /> -G- COPPER GROUND WIRE, SIZE AS NOTED 30A UNLESS NOTED OTHERWISE 20 DUPLEX, 20A, 120V, 10, 2P, 3W, STRAIGHT BLADE, NON-HAZARDOUS AREAS. <br /> cFcl ENCLOSED CIRCUIT BREAKER SIZE AS NOTED GROUND FAULT CIRCUIT INTERUPTING. EWC ELECTRIC WATER COOLER <br /> -LV- LOW VOLTAGE CONDUIT/WIRE ON DRAWING EXP EXPLOSION PROOF F. INSTALL 120 VOLT CONVENIENCE OUTLETS 48" A.F.F. FOR COLUMN MOUNTED <br /> FLOOR MOUNTED AND 18" A.F.F. FOR WALL MOUNTED. <br /> -FO- FIBER OPTIC, 3/4" MIN., WITH CABLE AS INDICATED, DISCONNECT SWITCH, FUSED, 30=SWITCH RATING, FOUR PLEX-2 DUPLEX 15A, 10, 2P, 3W,PARALLEL BLADE GROUNDED. EXST. EXISTING <br /> UNLESS SIZED OTHERWISE. NO CONDULET FITTINGS IN 3o FA FORCED AIR/FIRE ALARM <br /> 3o/zo 20=FUSE RATING � FLOOR MOUNTED FACP FIRE ALARM CONTROL PANEL G. UNLESS OTHERWISE NOTED, RECEPTACLES SHOWN MOUNTED ON STEEL COLUMNS <br /> FIBER OPTIC RUNS ALLOWED. SINGLE, 30A, 208V, 10, 2P, 3W, TWISTLOCK, GROUNDED SHALL BE MOUNTED IN COLUMN WEB. <br /> DISCONNECT SWITCH, NON-FUSED, 30A FATC FIRE ALARM TERMINAL CABINET <br /> -C- COMMUNICATIONS CIRCUIT UNLESS NOTED OTHERWISE ® IN CARPET MOUNTED COMBINATION COMM/POWER FLA FULL LOAD AMPERES H. CONDUITS AND CABLE TRAYS SHALL MAINTAIN A MINIMUM CLEARANCE <br /> IC WITH ONE DUPLEX 20A, 10, 2P, 3W, RECEPTACLES AND TEL/DATA JACKS OF 1'-0" FROM HOT WATER AND STEAM PIPES. ALL OTHER PIPING <br /> CONDUIT TURNED UP ® MOTOR CONTROLLER Q� CEILING MOUNTED 20A, 10, 2P, 3W RECEPTACLE,HUBBELL CAT NO 5362 FUT FUTURE GFI GROUND FAULT INTERRUPTER CLEARANCES SHALL BE A MINIMUM OF SIX (6) INCHES. <br /> CONDUIT TURNED DOWN ® CAPACITOR GND GROUND I. B.O.D. & B.O.T. DO NOT INDICATE BOTTOM OF REQUIRED HANGERS & <br /> 1A CONDUIT IDENTIFICATION <br /> m TRANSFORMER, SIZE AND TYPE AS NOTED LABELING AND SIGN REQUIREMENTS: HID HIGH INTENSITY DISCHARGE SUPPORT MATERIALS FOR DUCT AND TRAY. <br /> /� ELEVATION 100' " <br /> CABLE TRAY, SIZE AS NOTED ON THE DRAWINGS 4 MOTOR, 120V,10, SIZE AS NOTED A. PROVIDE SIGNS AS REQUIRED FOR EMERGENCY AND OPTIONAL STANDBY HISS HIGH PRESSURE SODIUM J. ALLAWIRNG, FITTINGSD UNCTIONNBOXES, CONDUIT, CON ROLL PANNELS, ETC.NSHALL L <br /> MOTOR, 208V, 30, SIZE AS NOTED SYSTEMS IN ACCORDANCE WITH WAC 296-46B-700 AND WAC HORZ. HORIZONTAL CONFORM TO CLASS 1 DIVISION 1 GROUP C & D REQUIREMENTS PER THE NATIONAL <br /> -U-t_r FLEXIBLE CONDUIT, 1/2" UNLESS NOTED OTHERWISE 296-466-702. HP HORSEPOWER ELECTRICAL CODE SECTIONS 500 AND 501. FROM ELEVATION 125-0" TO ELEVATION <br /> 4) MOTOR, 460V, 30, SIZE AS NOTED HVAC HEATING, VENTILATING AND 137'-0" ALL WIRING, FITTINGS, JUNCTION BOXES, CONDUIT, CONTROL PANELS, ETC. <br /> �Ff PREWIRED FLEXIBLE CONDUIT PROVIDED WITH LIGHT B. PROVIDE EMERGENCY SYSTEMS EQUIPMENT IDENTIFICATION IN ACCORDANCE AIR CONDITIONING SHALL CONFORM TO CLASS 1 DIVISION 2 GROUP C & D REQUIREMENTS PER THE <br /> FIXTURE TYPE R, R-2, S AND S-2 AS LST (LABOR © JUNCTION BOX, FIELD SIZED OR AS NOTED WITH WAC 296-4613-700. EXISTING PANELBOARDS THAT ARE DESIGNATED NATIONAL ELECTRICAL CODE SECTION 500 AND 502. ABOVE ELEVATION 137'-0" IS <br /> SAVING TANDEM) J❑ JUNCTION BOX, SQUARE 4" TO BECOME PART OF THE "EMERGENCY" SYSTEM SHALL BE RENAMED AND INST. INSTRUMENT/INSTRUMENTATION RATED AS NON-HAZARDOUS, UNLESS NOTED OTHERWISE. <br /> RE_LABELED TO REFLECT THEIR EMERGENCY DESIGNATION AS INDICATED IN JB JUNCTION BOX <br /> >� CONDUIT TO BE REMOVED GROUNDING PIGTAIL THE 'PANEL NOMENCLATURE' IDENTIFICATION BREAKDOWN SHOWN BELOW. K THOUSANDS OF CIRCU AR MILS K. ALL METAL RACEWAYS, THE METAL ARMOR OR METALLIC SHEATH ON CABLES, AND ALL <br /> EQUIPMENT TO BE REMOVED (EG. PANELBOARD) NON-CURRENT-CARRYING METAL PARTS OF FIXED OR PORTABLE ELECTRICAL EQUIPMENT, <br /> 0 PULLBOX, FIELD SIZED OR AS NOTED C. EXISTING BACKUP SYSTEMS AND/OR EQUIPMENT SUCH AS FEEDERS, KV KILOVOLTS REGARDLESS OF VOLTAGE, SHALL BE GROUNDED. <br /> (E) EXISTING ® JUNCTION BOX, SPECIAL. FIELD SIZED OR AS NOTED TRANSFER SWITCHES, DISTRIBUTION SWITCHBOARDS, PANELBOARDS, ETC., KVA KILOVOLT-AMPERES THAT ARE TO REMAIN IN SERVICE BUT ARE NOT CLASSIFIED AS KW KILOWATTS L. TO PREVENT SPARKS FROM THE ACCUMULATION OF STATIC ELECTRICITY, ALL ELECTRICALLY <br /> CONDUCTIVE OBJECTS, INCLUDING METAL PARTS OF SPRAY BOOTHS, HVAC DUCTS, DUCT <br /> N TELEPHONE OUTLET, WALL MOUNTED "EMERGENCY" SYSTEMS SHALL BE RENAMED AND LABELED AS STANDBY LTG LIGHTING <br /> DISTRIBUTION SYSTEMS IN ACCORDANCE WITH THE 'PANEL NOMENCLATURE' IDENTIFICATION SUPPORTS, METAL PIPING SYSTEMS, SYSTEMS CONVEYING FLAMMABLE COMBUSTIBLE LIQUIDS <br /> b DATA OUTLET, WALL MOUNTED MEZZ. MEZZANINE OR PAINT, SOLVENT LIQUIDS OR PAINT, SOLVENT TANKS, AND CANISTERS, SHALL BE GROUNDED. <br /> ® PANELBOARD, 48OV, 30, 3W, PANELBOARD E PUSHBUTTON STATION, TYPE AS NOTED BREAKDOWN SHOWN BELOW. MCC MOTOR CONTROL CENTER M. NO PRODUCTS CONTAINING SILICONE SHALL BE USED IN THIS BUILDING. <br /> PANELBOARD, 480Y/277V, 30, 4W, PANELBOARD, D. ALL EXISTING FEEDERS, BRANCH CIRCUITS, BOXES, ENCLOSURES, EQUIPMENT, MR MULTI-RATIO <br /> a SURFACE MOUNTED, FLUSH MOUNTED O THERMOSTAT RECEPTACLES, OUTLETS, ETC., THAT ARE FED FROM A RENAMED PANELBOARD MTR. MOTOR N. SEAL EACH CONDUIT AT THE CLASS 1 BOUNDARY PER NEC. <br /> v PANELBOARD, 208Y/12OV, 30, 4W, OR 30, 5W © CONTACTOR, TYPE AS NOTED OR SWITCHBOARD SHALL BE RE-LABELED TO MATCH THE NAMING USED FOR MV MEDIUM VOLTAGE <br /> a PANELBOARD SURFACE MOUNTED, FLUSH MOUNTED THE PANELBOARD OR SWITCHBOARD IN ACCORDANCE WITH THE ABOVE <br /> race MOTOR CONTROL CENTER ® CONTROL PANEL PARAGRAPHS AS APPLICABLE TO "EMERGENCY" AND "STANDBY" SYSTEMS. NEC NATIONAL ELECTRIC CODE COLOR CODES <br /> [� SPECIAL PANEL AS NOTED ® RELAY NEMA NATIONAL ELECTRICAL 120/208 COMPUTER CIRCUITS <br /> PANEL NOMENCLATURE MANUFACTURERS AssoCarloN C I q �q T �p <br /> INDICATES WALL MOUNTING N.C. NORMALLY CLOSED IRE ALARM SYSTEM PHASE COLOR <br /> SINGLE LINE DIAGRAM XE 3 V03-1 a D12-1-D A BLACK <br /> TELEPHONE BY <br /> DATA/POWER POLE N.I.C. NOT C CONTRACT WALL MOUNT HORN/STROBE B <br /> «^�> � SUFFIX "-D" INDICATES DISTRIBUTION PANEL � SUBSCRIPT ##CD = CANDELA RATING RED <br /> CIRCUIT BREAKER, AIR, DRAW OUT PROVIDED BY SYSTEMS FURNITURE MFR. O.C. ON CENTERS <br /> TELEPHONE AND DATA/POWER POLE SUFFIX "MU IP -3, ETC." IS USED TO SUBSCRIPT WP = WEATHER PROOF C WHITE PHASE TAPE BOTH <br /> PBRD. PANELBOARD ( <br /> ® FUSE O INDICATE MULTIPLE PANELS AT SAME LOCATIONCEILING MOUNT ENDS BLUE OR YELLOW) <br /> PROVIDED BY ELECTRICAL CONTRACTOR WHICH ARE SAME VOLTAGE, FED FROM SAME PH. PHASE SUBSCRIPT ##CD =HOR CANDELA RATING NEUTRAL WHITE <br /> STROBE <br /> TRANSFORMER VAULT AND LOCATED ON SAME FLOOR RECP. RECEPTACLE ® WALL MOUNT STROBE EQPT. GROUND GREEN <br /> S SINGLE POLE SINGLE THROW <br /> LIGHTING NOTE: IF SUFFIX "-A, -B, -C, ETC." IS BEING SWW.. SUBSCRIPT ##CD = CANDELA RATING SWITCH 120/208VAC POWER <br /> CURRENT TRANSFORMER A FIXTURE TYPE DESIGNATION. SEE FIXTURE SCHEDULE, USED INSTEAD OF "-1, -2, -3, ETC.", THEN SMOKE DETECTOR, <br /> SWGR. SWITCHGEAR s SUBSCRIPT X:XX = DEVICE ADDRESS PHASE COLOR <br /> -3a <br /> SHT. EOb QUANTITY AND RATING OF LAMPS CONTINUE USING SUFFIX LETTERS FOR CLARITY x:xx <br /> GROUND <br /> � (A=TYPE, 2=QUANTITY, 34=L TYR. TYPICAL AMP RATING) A BLACK <br /> PANEL LOCATION AT NEAREST COLUMN V. VOLT O HEAT DETECTOR, B RED <br /> - ® x:xx LOCATION OF PANEL WHEN NOT ON FIRST FLOOR: VFD VARIABLE FREQUENCY DRIVE SUBSCRIPT X:XX = DEVICE ADDRESS C BLUE <br /> ® AMMETER FLUORESCENT FIXTURE, 3 LAMP, TYPE AS NOTED M = MEZZANINE U = 2ND FLOOR VERT. VERTICAL F❑ MANUAL STATION, <br /> x:xx NEUTRAL WHITE <br /> P = PENTHOUSE UT = UTILIDOR VPB VERTICAL PAINT BOOTH SUBSCRIPT X:XX = DEVICE ADDRESS 0 GROUND GREEN VOLTMETER FLUORESCENT FIXTURE, 2 LAMP, TYPE AS NOTED R = P1 PARKING FLOOR V = ZED FLOOR W WATT SMOKE DUCT DETECTOR <br /> S = P2 PARKING FLOOR W 4TH FLOOR � PROVIDED BY OTHERS) 277/480 VAC POWER CABLES <br /> I ) ENCLOSED CIRCUIT BREAKER T TRUSS LEVEL X = 5TH FLOOR W/ WITH <br /> Li I SIZE AS NOTED TN = TUNNEL W/o WITHOUT MMM MINI MONITOR MODULE, PHASE COLOR <br /> FLUORESCENT FIXTURE ON EMERGENCY SYSTEM, SUBSCRIPT X:XX = DEVICE ADDRESS <br /> TYPE AS NOTED WP WEATHERPROOF A BROWN <br /> AUXILIARY SYSTEMS ® SOURCE OF POWER: VAULT NO. XFMR. TRANSFORMER FATC FIRE ALARM TERMINAL CABINET g ORANGE <br /> FLIGHTLINE EXAMPLE: VS38 FOR SUBSTATION S38 FACP FIRE ALARM CONTROL PANEL <br /> FLUORESCENT FIXTURE WITH BRANCH CIRCUIT CH GROUSE HINDS C YELLOW <br /> $y P.A. SYSTEM ATTENUATOR, WALL MOUNTED, ® CONNECTION POINT 1 LAMP, TYPE AS NOTED VOLTAGE AND ASSOCIATED PANEL SYMBOL: CLASS I DIV. 1 RATED FAC FIRE ALARM COMMUNICATOR (CELLULAR DIALER) NEUTRAL WHITE/GREY <br /> 10 WATT RATING FLUORESCENT FIXTURE WITH BRANCH CIRCUIT GRC GALVANIZED RIGID GROUND GREEN <br /> SPEAKER, RECESSED MOUNTED IN CEILING ® CONNECTION POINT 2 LAMP, TYPE AS NOTED ® 4 = 480V, 3PH, 3W STEEL CONDUIT RPS REMOTE POWER SUPPLY <br /> ® 3 480Y/277V, 3PH, 4W 28 VOLT D.C. CIRCUITS <br /> FA_NUl ANNUNCIATOR INCANDESCENT FIXTURE, TYPE AS NOTED 0 2 = 208Y/12OV, 3PH, 4W OR *NOTE: SEE SHEET E510 FOR ADDITIONAL <br /> ® TELEPHONE CABINET EXIT LIGHTING SIGN, WALL MOUNTED. © 120/24OV, 1PH, 3W FIRE ALARM ABBREVIATIONS. POSITIVE (+) RED <br /> �� © 5 = 400 HZ, 575Y 331V, 3PH, 4W <br /> NEGATIVE (-) BLACK <br /> LS LIMIT SWITCH DIRECTION OF EGRESS AS NOTED 0 2 = 400 HZ, 200Y/115V, 3PH, 4W <br /> ® EXIT LIGHTING SIGN, SUSPENDED OR CEILING 1 28 VDC 15 KV POWER CABLES <br /> MOUNTED. DIRECTION OF EGRESS AS NOTED PREFIX: <br /> O FIXTURE OUTLET (SHOWN WITH FIXTURES) (BLANK)= NORMAL POWER PANEL PHASE COLOR <br /> OS OCCUPANCY SENSOR 11 I" ISOLATED GND PANEL A BLACK/PURPLE BAND <br /> "Z" = 400 HZ PANEL B RED/PURPLE BAND <br /> "XE" = EMERGENCY PANEL C BLUE/PURPLE BAND <br /> "XL" = LEGALLY REQUIRED STANDBY PANEL GROUND GREEN <br /> "XS" OPTIONAL STANDBY PANEL -� <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY ,f,$, 06/20/24 DAIL SUBTITLE CURRENT REVISION SYMBOL n DATE <br /> A EVERETT 40-36 ADD 4 HEAT DETECTORS 35074790 FASDESION AOOW/KM 06/20/24 THIS DESIGN AND/OR CHECKED ELECTRICAL LEGEND&ABBREVIATIONS A 06/20/24 <br /> SPECIFICATION IS APPROVED K.M. 06/20/24 SHEET <br /> N IN TITLE E 0 <br /> BOE/NG® APPROVED By DEPT. DATE K.M. 06/20/24 <br /> CHECKED <br /> APPROVED BUILDING 40-036 JOB NO, 35074790 COMP N0. <br /> APPROVED EVERETT, WA DWG NO. 40-036-GO <br />