LEGEND <br /> FIRE ALARM ABBREVIATIONS 4036 BUILDING FACP POINTS SEE SHEET EO <br /> ALT SECONDARY OR ALTERNATE ELEVATOR RECALL POINT NUMBER/ZONE BOEING DESCRIPTION FACP POINT - COMMENTS - GRID/SHEET LOC. <br /> BEAM DET BEAM DETECTOR L1:001 SV36-1 WF PRESSURE WATERFLOW PRESSURE SWITCH WITH DELAY R/12.7 - 1E269 <br /> CDR COMPUTER/NETWORK/DATA/IDF ROOM L1:002 SV36-1 WE ISO TAMPER WATERFLOW ISOLATION TAMPER SWITCH R/12.7 - 1E269 <br /> COL COLUMN L1:003 SV36-1 TAMPER SPRINKLER PIV R/12.7 OUTSIDE WALL - 1E269 <br /> COMMAIL COMMUNICATION FAILURE <br /> CTRL CONTROL /L1:004 SV36-IA TAMPER OS&Y SPRINKLER VALVE R 12.5 - 1E269 <br /> TRL <br /> CW CATWALK L1:005 SV36-1A HI/LO AIR HI/LO AIR PRESSURE SWITCH R/12.5 - 1E269 <br /> DMPR DAMPER L1:006 SV36-1A WE PRESSURE WATERFLOW PRESSURE SWITCH R 12.5 -1E269 <br /> DID DUCT SMOKE DETECTOR L1:007 SV36-3 WE PRESSURE WATERFLOW PRESSURE SWITCH WITH DELAY R/12.7 - 1E269 <br /> DIESEL DIESEL <br /> FP FIRE PUMP L1:008 SV36-3 WE ISO TAMPER WATERFLOW ISOLATION TAMPER SWITCH R/12.7 - 1E269 <br /> ELEC ELECTRICAL; ELECTRICAL ROOM L1:009 SV36-3 TAMPER SPRINKLER PIV R/12.7 OUTSIDE WALL - 1E269 <br /> ELEV ELEVATOR L1:010 SV36-5 WF PRESSURE WATERFLOW PRESSURE SWITCH WITH DELAY R/12.7 - 1E269 <br /> EPP EXCESS PRESSURE PUMPFACP FIRE L1:011 SV36-5 WF ISO TAMPER WATERFLOW ISOLATION TAMPER SWITCH R/12.7 - 1E269 <br /> ELEV FF HAT LIGHT FIRE FIGHTER ER RM OHAT RLIGHT INOL LA ELEVATOR L1:012 SV36-5 TAMPER SPRINKLER PIV R/12.7 OUTSIDE WALL - 1E269 GENERAL NOTES <br /> FLR FLOOR L1:013 SV36-7 WF PRESSURE WATERFLOW PRESSURE SWITCH WITH DELAY R/12.7 - 1E269 <br /> FM HEAT HEAT DETECTOR FIRE MAIN VALVE L1:014 SV36-7 WE ISO TAMPER WATERFLOW ISOLATION TAMPER SWITCH R/12.7 - 1E269 <br /> HE <br /> INTDEV INTERFACE DEVICE, MONITORING OR CONTROL L1:015 SV36-7 TAMPER SPRINKLER PIV R/12.7 OUTSIDE WALL - 1E269 <br /> ISO ISOLATION VALVE L1:016 SV36-9 WF PRESSURE WATERFLOW PRESSURE SWITCH WITH DELAY R/13.5 - 1E270 <br /> KITCHEN KITCHEN L BATT LOW BATTERY L1:017 SV36-9 WE ISO TAMPER WATERFLOW ISOLATION TAMPER SWITCH R/13.5 - 1E270 <br /> L FUEL LOW FUEL (FIRE PUMP DIESEL TANK IS BELOW 50% FILLED) L1:018 SV36-9 TAMPER SPRINKLER PIV R/13.5 OUTSIDE WALL - 1E270 <br /> LBY LOBBY L1:022 UV36-5A TAMPER OS&Y SPRINKLER VALVE R/12.7 - 1E269 <br /> LRD LOW RATE DISCHARGE L1:023 UV36-5A WE WATERFLOW SWITCH R/12.7 - 1E269 <br /> MAN PULL MANUAL PULL STATION <br /> MECH MECHANICAL ROOM L1:024 SMK @ FACP P.5 14 - 1E270 <br /> NAC NOTIFICATION APPLIANCE CIRCUIT OR POWER SUPPLY L1:025 MAN PULL @ FACP P.5 14 - 1E270 <br /> OS&Y OUTSIDE SCREW AND YOKE VAVVE L1026 ELEV 66 67 FA P.5 13.7 - 1E270 <br /> PD PUMP DISCHARGE VALVE <br /> PH PENTHOUSE L1:027 ELEV 66 67 TRBL P.5 13.7 - 1E270 <br /> PIV POST INDICATOR VALVE L1:028 MAIN VESDA PANEL FA P 12 - 1E269 <br /> POWER FAIL FACP POWER FAILURE <br /> PREACT PREACTION SYSTEM L1:030 7PME HEAT 1 HEAT DETECTER N.6 13 DAKOTA TOWER REFERENCE D RAW N G S <br /> PRI PRIMARY <br /> PS PUMP SUPPLY VALVE L1:031 7PME HEAT #2 HEAT DETECTER N.6 13 DAKOTA TOWER <br /> PWR POWER L1:032 7PME HEAT #3 HEAT DETECTER N.6 13 DAKOTA TOWER <br /> RF ROOF RLY RELAY L1:033 7PME HEAT #4 HEAT DETECTER N.6 13 DAKOTA TOWER <br /> SEC SECTION VALVE <br /> SHUNT SHUNT TRIP <br /> SMK SMOKE DETECTOR <br /> STL STALL BUILDING FACP POINTS LIST (#1 -50) <br /> STROBE STROBE, HORN OR ANY NOTIFICATION DEVICE SCALE: NONE <br /> SUPPR SUPPRESSION E50`6-1 <br /> SUPV SUPERVISORY <br /> SV SPRINKLER VALVE <br /> TAMPER TAMPER SWITCH <br /> TL300 TL300 TYCO COMMUNICATION DEVICE <br /> TRBL TROUBLE <br /> UV UNIT VALVE PART # ITEM DESCRIPTION UNIT QUANTITY <br /> VLv VALVE <br /> WE 76-800100-001 ARIES NETLINK CONTROL UNIT EA 1 (EXISTING) <br /> ZN ZONERFLOW SWITCH 76-800010-002 PCB FOR ARIES NETLINK UNIT EA 1 (EXISTING) <br /> 76-800010-001 EXPANSION CARD CAGE EA 1 (EXISTING) <br /> Power Supply and Battery Size Calculation 70-407017-001 Al MODULE N/O EA 4 <br /> A Total Stand-By Current per System: p2ti6 Amps <br /> 27121-20 HEAT DETECTOR EA 4 <br /> B Taal Alarm Current per System: 0.443 Amps <br /> D Enter Stand-By <br /> Tinne: a: 48 Hour <br /> 10Minu FIRE ALARM BILL OF MATERIALS <br /> D EnYr Alarm Time: 10 Minute <br /> E Ampare Hour Required((A-C)w(B•D)): 12.94 AH SCALE: NONE E506-1 <br /> F Total Amp Hour Require(Berating Factor 1.2): 16.00 AH <br /> Right-Click to Update,Print and Clear Battery Calculation. <br /> e Battery Sim Required per System(two(2)batteries required): 16 AH <br /> 20.0000 <br /> H 3-Tiered Main or Expansion Enclosure,Max.20 Amps* 0 Amps <br /> I Expansion Enclosure(s)Required? YES <br /> d Number of Enclosure(Main/Expansion)Required: 1.00000 <br /> K Number of Power Management Unit(PMU)Board Required: 1 <br /> L Number of Power Supply Unit(PSU)Required: 1 <br /> Unit "Total "Total <br /> "Enter Standby On it "Unit Unit <br /> Quantity Curren Standby Current Alarm Current Alarm Current <br /> "Ite Description (Amps) <br /> 1.000 <br /> 00 MCB(with Keyboard/Display) 1.00000 0.158 0.158 0.300 0.300 <br /> 2.00 Digital Alarm Communicator Transmitter(DACT)Expansion Card(Max. <br /> 000 1 Per System) 1.00000 0.024 0.024 0.037 0.037 <br /> 3.00 <br /> 000 Smart0ne Photoelectric Smoke Detector DS-PS 1.00000 0.000150 0.000150 0-000220 0.000220 <br /> 4.00 27.0000 <br /> 000 Smart0re Contact Input Module(AII N/O) 0 0.000580 0.015660 0-000580 0.015660 <br /> 5.00 <br /> 000 Power Management Unit(PMU)Board#1,Max.10.8 Amps 1-00000 0.070 0.070 0.090 0.090 <br /> FIRE ALARM PANEL BATTERY CALCS. <br /> SCALE: NONE E506-1 <br /> GOW <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY <br /> R CHECKED os zo z4 FIRE ALARM SYSTEM RISER DIAGRAM A 06/20/24 <br /> A EVERETT 40-36 ADD 4 HEAT DETECTORS 35074790 FASDESIGN AGOW/KM 06/20/24 SPECIFICATION IS APPROVED K.M. 06 20 24 SHEET SEQUENCE NO. <br /> LNGINLLH""ALE V6TITLE E506-1 <br /> APPROVED BY DEPT. DATE K.M. 06 20 24 <br /> CHECKED <br /> APPROVED BUILDING 40-036 35074790 <br /> APPROVED EVERETT, WA DWG NO. 40-036-E506-1 <br />