Laserfiche WebLink
8" 12 GA. HANGER 8" BERC2 CLIP <br /> BERC2 CLIP MAX. WIRE 4'-0" o.c. MAX. <br /> POP RIVET MAIN RUNNER (SEE DETAIL 1) <br /> O WALL OR CROSS TEE WALL <br /> n <br /> n CROSS TEE CROSS TEE ANGLE ACOUSTICAL <br /> BOARD WALL <br /> WALL 1/8" POP RIVET (NO POP RIVETS) ANGLE <br /> PROVIDE 3/4" SPACE AT WALL <br /> MEMBER AT OPPOSING WALL <br /> WALL ANGLE (ATTACHED WALLS) (UNATTACHED WALLS) <br /> #8 x 1/2" ROUND WASHER HEAD TEK <br /> WALL ANGLE SCREW (SELF— TAPPING) ATTACHED WALL HHAANNG <br /> NOTE: SCREW IS NOT TIGHTENED DOWN GER AND PERIMETER WIRES MUST BE PLUMB WITHIN 1:6 UNLESS AGAINST BERC2 CLIP (TWO ADJACENT WALLS) COUNTER SLOPING WIRES ARE PROVIDED <br /> LATERAL—FORCE BRACING: <br /> UNATTACHED WALL <br /> SEISMIC BERC2 CLIP IS THE USE OF VERTICAL STRUTS AND SPLAY WIRES. <br /> (TWO ADJACENT WALLS) —FACTORY INSTALLED AT TWO ADJACENT WALLS. CEILING AREAS OF 1000 SQ.FT. OR LESS SHALL BE EXEMPT FROM <br /> —SCREW TIGHTENED FOR SHIPPING IN ROOMS WHERE LATERAL—FORCE BRACING REQUIREMENTS. <br /> CEILING CROSSES MOD LINE, LOOSEN SCREW ON SITE CEILINGS WITH INTERSTITIAL SPACE LESS THAN 12" TO FRAMING <br /> BY SET UP CREW ARE NOT REQUIRED TO HAVE LATERAL—FORCE BRACING. <br /> —NOT REQUIRED FOR CEILINGS LESS THAN OR EQUAL SEISMIC SEPARATION JOINTS: <br /> TO 144 SF AND SURROUNDED BY WALLS CONNECTED TO ALL CONTINUOUS CEILING AREAS EXCEEDING 2500 SQ.FT. SHALL <br /> THE STRUCTURE ABOVE. HAVE A SEISMIC SEPARATION JOINT. <br /> —SOURCES: ASCE 7-16 SECTION 13.5.6 EXCEPTION 1, <br /> 1 SECTION SEISMIC ATTACHMENT AT WALLS 2 STANDARD T-BAR DETAIL <br /> N.T.S. [ARMSTRONG SEISMIC 'Rx' SUSPENSION SYSTEM (ESR 1308)] N.T.S. <br /> O SUSPENDED T—BAR SEISMIC BERG CLIP O <br /> C —FACTORY INSTALLED <br /> CEILING GRID 2 x 2 SUPPLY <br /> AT TWO ADJACENT WALLS SEE DETAIL (2/A-5) SEE DETAIL (1/A-5) AIR DIFFUSER <br /> 71 71 1 7 7T 71 7 1 71 7 71 <br /> O <br /> 77,< <br /> ZE H <br /> O I O <br /> `WALL MOUNTED <br /> EXHAUST FAN <br /> TYP. OF 3 <br /> REFLECTED CEILING PLAN <br /> SCALE:114"=V-0" <br /> CUSTOMER APPROVAL <br /> ❑APPROVED <br /> STATEMENT OF SPECIAL INSPECTIONS ❑APPROVED EXCEPT AS NOTED <br /> The materials,systems,components,and work required to have special ❑ REVISE AS NOTED AND RESUBMIT <br /> inspections are listed below. Inspections will be completed by the APPROVED By Date <br /> engineer of record. <br /> Special inspection for suspended ceiling system: /� <br /> Periodic inspection of the suspended ceiling system PRELIMINARY <br /> L IMI N to verify that it ' ` A ` 1[��/ <br /> complies withESR-1308. NOT FOR CONSTRUCTION <br /> 12-7-21 PRELIM REVIEW-DG LDG COPYRIGHT 2021,BLAZER INDUSTRIES,INC. MOBILE Approved for Const Job No: 20080 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERLY A DA RR for: <br /> ;j? <br /> OF BLAZER INDUSTRIES,INC.AND SHALL ■■ File Copy: <br /> NOT BE REPRODUCED,USED,OR DISCLOSED 10 x 46 port of Everett - Norton ExpansionA=5 <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE INDUSTRIES,wa Drawn By: LDG <br /> DATE REVISION 3Y WRLITEN PERMISSION OF BLAZER INDUSTRIES. I=.D.eoxaas wwrv.Dlazednd.mm WA Pacific Mobile Everett,WA <br /> �� ?45 Olney St. ■ Au—ille,OR 97325-0404 Issue Date: f2-7-21 <br />