n A <br /> PACKAGE *SPVU* HIGH EFFICIENCY WALL MOUNT HEAT PUMP — SCHEDULE <br /> SNCLE POINT <br /> DO FAN SENSIBLE HEATING HEAT CONNECTION <br /> BLOWER BLOWER EFFICIENCY VENTIL COOLING COOLING CAPACITY HEATING HEAT STRIPS UNITUNIT BARD UNIT UNIT MOTOR AJRFLOW SPEED BLOWER GRADE VFNTR- (FA) FILTER OUTDOOR ENTERING ENTERING CAPACITY CAPACITY 47degs COP UNIT UNIT STRIPS OUTPUT MCA MOCP <br /> TAG UNIT MODEL NUMBER SZE OTT TYPE CFM SETTING HP (FEG) DEVICE CFM TYPE EER (08)TEMP (DB)TEMP (WB)TEMP BTLIH STUN BTUH 47degs HERTZ VOLTS PHASE KW STUN AMPS AMPS WGT ADDITIONAL NOTES <br /> HP—i W48HC—A15ZP4XXR 4.0 1 ECM 1696 LIED 3/4 _ ECON MERV-8 11 95 80 67 48.330 37.679 41.378 3.3 60 240 1 15 51.195 87 1 90 505 1'2'3'4.5,8,7,8,900, <br /> ADDITIONAL NOTES: <br /> I I—CAPACITY USTED ABOVE ARE IN ACCORDANCE WITH ANS/ARI STANDARD 390-2DO3 FOR SPVU(SINGLE PACKAGE VERTICAL UNITS) Seouence of ooaratian: <br /> 2—COMPLIES WITH EFFICIENCY REQUIREMENTS OF ANSI/ASHRAE/IESNA 90.1-2076 1—Upon a Cooling call from the room thermostat the unit will be in mechanical cooling <br /> 3—BARD THERMOSTAT(8403-080),7—DAY PROGRAMMABLE mode. <br /> 4—BARD INDOOR REMOTE SENSOR.(8403-062) 2— Upon a heating call from the room thermostat the unit will be in mechanical heating, <br /> 5—DELETED 2nd stage heat strips will come on if the room temperature drops below <br /> 6—HEAT STRIPS KIT WITH CIRCUIT BREAKER Its setpoint and during defrost. <br /> 7-DELETED 3- DELETED <br /> 6-2"PLEATED FILTER,MERV-8 4- These modes with keep repeating and required by the thermostat <br /> PLENUM VA R I F I CAT I O N 9-UNIT COLOR IS'BUCKEYE GRAY 5_ if this h t Is equipped with a exterior door op dawn kit the unit mechanical system <br /> 10-WTOOIXt THERMOSTAT SET AT 40DEC'S k LAC CONTROL(R)CONTROL will io shut down alter the exterior has been open for it minutes.The Ventilation <br /> 11-DELETED portion will keep operating.Once the door closes the unit will restart If there Is still <br /> 12-(BSDTIMER)KIT-PROVIDES A MEANS ON SHUTTING DOWN OF THE MECHANICAL COGUNG AND HEATING SYSTEM,VENTILATION CONTINUES TO OPERATE,VIA EXTERIOR DOOR SWITCH(OPTIONAL) a call from the thermostat. <br /> SCALE:1/2"=1'-0" <br /> Ma To REFER TO glStALLATON INSTRUCnWS FOR START UP AND EOURMENT sal <br /> M. TO 06M STE VMTACE AND SET CORRECT TAP ON TRANSFORMER <br /> M.0 TO GRAM SET ANO PRO THERMOSTAT PER OLST011ERS REG:VIREMENTS <br /> e WQ To SET ANO 1NEM ECONRI@A AND VENIILATIDN PRE PRP RE:OURE'AaN3 <br /> O O <br /> MECHANICAL NOTES: [RELIEF VENT WITH <br /> BACKDRAFT DAMPER <br /> WA - 2018 IMC WAC AND 2018 WSEC TYP. OF 4 <br /> 1. VENTILATION PROVIDED VIA NATURAL VENTILATION IN ACCORDANCE WITH IMC SECTION 402 IN OVIAii <br /> LIEU OF DOAS REQUIREMENTS. [WSEC SECTION C 403.3.5 EXCEPTION 1] 4 TON 15 kW <br /> 2. MECHANICAL EQUIPMENT INSTALLATION IN OR ON THIS BUILDING SHALL BE IN ACCORDANCE WITH WALL HUNG <br /> THE REQUIREMENTS OF IMC WAC CHAPTER 5 UNLESS OTHERWISE EXEMPTED. HEAT PUMP <br /> 3. DUCT MATERIAL IS 26 GA. GALVANIZED WITH 2.2"FSK INSULATION. DUCTWORK SHALL BE <br /> SUPPORTED. [IMC WAC SECTION 603] 1 2Fq <br /> 4. ROUND FLEX DUCT SHALL BE UL LISTED CLASS 1, STANDARD 181 - FACTORY MADE AIR T 12 <br /> DUCTSAND AIR CONNECTORS.THE MINIMUM THERMAL PERFORMANCE SHALL BE AT R-6, AND <br /> MEASURED IN ACCORDANCE WITH ATSM C 518 OR ATSM C 177 AT 75DEG F MEAN 12 <br /> TEMPERATURE. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURERS INSTALLATION <br /> INSTRUCTIONS. <br /> 5. MATERIAL IN DUCTS SHALL HAVE A FLAME SPREAD INDEX OF LESS THAN 25, SMOKE PLENUM #PWS134 <br /> DEVELOPMENT OF 50. [IMC SECTION 602] <br /> 6. LOW PRESSURE DUCT SYSTEMS SHALL HAVE LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS <br /> AND CONNECTIONS OF SUPPLY AND RETURN DUCTS AND PLENUMS SECURELY FASTENED AND B <br /> SEALED WITH WELDS, GASKETS, MASTICS (ADHESIVES), MASTIC-PLUS EMBEDDED-FABRIC WALL MOUNTED <br /> SYSTEMS OR APPROVED TAPES INSTALLED IN ACCORDANCE WITH IMC WAC SECTION 603.9. WALL MOUNTED EXHAUST FAN <br /> 7. DUCT INSULATION SHALL COMPLY WITH IMC WAC SEC 604. EXHAUST FAN TYP. OF 3 <br /> B. WHEN ISOLATION SLEEVES ARE USED AT LINE CONNECTIONS TO PLENUMS, THEY SHALL COMPLY TYP. OF 3 <br /> WITH IMC WAC CHAPTER 6. <br /> 9. IF DIFFUSERS HAVE NO MANUAL DAMPERS, USE FLOW CONTROL AT WYES. TYPICAL AS NOTED ON TYPICAL DOOR SWITCH WITH MECHANICAL PLAN <br /> PLAN. TIME DELAY WIRING FOR HEAT PUMPS <br /> 10. MINIMUM OUTSIDE AIR VENTILATION PER IMC WAC TABLE 403.3.1.1. THIS DRAW INOIS SHOWN WM1A JUMPER WIRE SCALE:1/4"=V-0" <br /> INSTALLED ON TERMINALS 41 TO s2'DOOR <br /> 11. OUTSIDE AIR DAMPERS SHALL COMPLY WITH WSEC, SECTION C403.7.8. STVITOH JUMPER•WRE.REMOVE JUMPER WHEN <br /> DOOR SWITCH IS INSTALLED,WIRED AS SHOWN. <br /> 12. ALL NEW SYSTEMS REQUIRE ECONOMIZERS UNLESS EXEMPTED BY EXCEPTIONS. [WSEC SECTION <br /> 403.5] O 0 <br /> 13. DOOR SWITCH CONTROLS SHALL BE INSTALLED IN ACCORDANCE WITH WSEC 403.4.1.6 AT ALL ---------ice <br /> DOORS THAT OPEN TO THE OUTDOORS. j RT MECHANICAL SYMBOLS <br /> 14. MECHANICAL DRAWINGS SHOW DUCTWORK SIZES TO BE CLEAR INSIDE DIMENSION. __i —_____2 W2® ®G <br /> 15. ELECTRICIAN MUST VERIFY ALL ELECTRICAL REQUIREMENTS AND LOCATIONS. 1 I a® SYMBOL DESCRIPTION <br /> 16. CONTRACTOR SHALL ARRANGE ALL HVAC UNITS AND ASSOCIATED ITEMS FOR ACCESS I I 4 3® ®C ® 2'x2' SUPPLY AIR DIFFUSER <br /> CLEARANCES. i i E® ®Y <br /> 17. THERMOSTAT SCHEDULING TO BE PERFORMED ON SITE BY OTHERS. i i s® <br /> I 1 L® ®Y1 _____= EXHAUST FAN DUCT/RELIEF AIR GRILLE DUCT <br /> 18. ALL HVAC EQUIPMENT LEAVES FACTORY WIRED FOR 240 VOLT OPERATION. <br /> 19,THE ACCEPTABLE OPERATING RANGE FOR THE 240V& 208V TAPS ARE: i 7® AB g EXHAUST FAN WITH HOOD <br /> TAP RANGE e I I ® 019 �VY1 <br /> 240 253 -216 1 INSTALLED <br /> I I O O � 14"x14" RELIEF VENT WITH BACKDRAFT DAMPER <br /> I I WIRES ADONEW UNITLOWVOLTAGE <br /> 208 220-187 I I TERMINAL TERMINAL BLOCK <br /> — <br /> 20.SITE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR MAKING SURE THE RIGHT TAP IS i i aBLOCK —X SUPPLY DUCT w/DIAMETER INDICATOR <br /> CONNECTED FOR THE APPLIED SITE VOLTAGE. e607-02I <br /> 1 L-- ( THERMOSTAT <br /> 21. AIR FILTERS IN HVAC UNITS OR SYSTEMS ARE TO BE CHANGED EVERY 30 DAYS BY OTHERS ON i �000R SWITCH(FIELD <br /> SITE. I SWITCH ISS OPEN WHEN WHEN DOOR <br /> ISWT OPENPO'm'N <br /> 22.REGISTER AIR FLOW TEST AND BALANCE OF HVAC SYSTEM TO BE PROVIDED AND PERFORMED BY SWRCHLRCLaSBDWHENOOOR RS REMOTE SENSOR <br /> OTHERS ON SITE WHEN REQUIRED. L_____� IswTHE CLasED PosmoN <br /> 23.HVAC SITE CONTRACTOR IS RESPONSIBLE FOR BALANCING THE SYSTEM. BALANCING SHALL BE IN THIS KIT WILL COMPLY WrrH WSEC G03 1.6 <br /> ACCORDANCE WITH IMC WAC 403.3.1.5. CUSTOMER <br /> I ICTOA ACD APPROVAL <br /> ❑APPROVED <br /> ❑APPROVED EXCEPT AS NOTED PRELIMINARY <br /> El REVISE AS NOTED AND RESUBMIT <br /> APPROVED By Date NOT FOR CONSTRUCTION <br /> 12-7-21 PRELIM REVIEW-DG LOG COPYRIGHT2021,BLAZER INDUSTRIES,INC. MOBILE ADARR for <br /> App—ed for Ccnst Job No: 20080 <br /> THIS MATERIAL IS THE IXCLUSIVE PROPERTY <br /> OF BLAZER INDUSTRIES,INC.AND SHALL ■■ File Copy: <br /> NOT BE REPRODUCED,USED,OR DISCLOSED 10x46 port of Everett se Norton Expansion <br /> INDUSTRIES,INC. <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE CIAO.BOX 489 wwwDlazedna.wm Drawn By: LDG <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. �� 9as Olney sL ■ Aumsville,OR 97325M89 WA Pacific Mobile Everett,WA Issue Date: 12-7-21 <br />