GENERAL NOTES: <br /> O O <br /> 1. WHEN STRANDED WIRE IS USED.ALL TERMINATIONS ARE MADE BY <br /> A PRESSURE TERMINAL,BY TAILING OFF WITH SOLID CONDUCTORS <br /> O OR OTHER APPROVED MEANS OF TERMINATION. <br /> A D ii DS <br /> 2. ALL CONDUCTORS ARE COPPER:TYPE THHN/THWN <br /> �^ GFCI - - n O 3. RATING OF STANDARD PANEL IS 22,D00 A.I.C. <br /> 44" 4. WIRING METHOD IN METALLIC CONDUIT OR M.C.CABLE. <br /> I <br /> T ate_ S. BREAKER LOCK OUT DEVICE SHALL BE INSTALLED ON ALL <br /> PERMANENTLY CONNECTED APPLIANCES.2020 NEC 422.31 <br /> 6. HVAC DISCONNECTS SHALL BE LABELED WITH AN IDENTIFICATION <br /> WP PLATE SHOWING CIRCUIT SOURCE PANELBOARD,CIRCUIT <br /> GFCI � WH _Jo O NUMBER AND EQUIPMENT SERVED.WAC296-46B-110022 <br /> 7. EXTERIOR WEATHER PROOF GFCI SHALL HAVE A"HEAVY DUTY" <br /> O WEATHER PROOF"IN USE'COVER.2020 NEC 406.9(8)(1) <br /> Iul WALL MOUNTED B. CONTROLLED RECEPTACLES SHALL BE LABELED PER 2020 NEC <br /> EXHAUST FAN <br /> TYP. OF 3 406.3(E)WITH THE TEXT"CONTROLLED"AND THIS SYMBOL <br /> 9. THIS PLAN IS NOT AN"AS-BUILT'CIRCUITS MAY BE RUN DIFFERENT <br /> THAN SHOWN BASED ON OBSTACLES ENCOUNTERED. <br /> ELECTRICAL PLAN <br /> SCALE: 1/4"=1'-0" ars 17 <br /> CUSTOMER APPROVAL <br /> ❑APPROVED <br /> ❑APPROVED EXCEPT AS NOTED <br /> ❑ REVISE AS NOTED AND RESUBMIT <br /> APPROVED By Date <br /> PRELIMINARY <br /> NOT FOR CONSTRUCTION <br /> ELECTRICAL SYMBOLS <br /> SYMBOL DESCRIPTION AFF <br /> TO TOP REMARKS <br /> ELECTRICAL PANEL <br /> B WEATHER PROOF 36" <br /> DUPLEX RECEPTACLE CONTROLLED 20" 180 VA EACH <br /> �WWEATHER RESISTANT GFCI 20" 180 VA EACH <br /> RECEPTACLE <br /> b90 nUGHT DIMMING CONTROL 48" 1 ZONE DIMMING CONTROL <br /> .,,T WALL MOUNT TIMER 48" EXTERIOR LIGHTING CONTROL <br /> 7 DAY PROGRAMMABLE <br /> QTY. SIZE DESCRIPTION ® nUGHT PLUG LOAD CONTROL ABOVE CONTROLLED BY nUGHT ENABLED <br /> RELAY CEILING FIXTURE OCCUPANCY SENSORS <br /> ELECTRICAL PANEL 1 200 AMP SINGLE PHASE - NEMA 3R - 120/240 VOLT , PHONE/DATA ROUGH IN 4" 20" 3/4" FLEX STUBBED UP AND DOWN <br /> SQ BOX w/SINGLE GANG MR <br /> HVAC 1 4 TON BARD 15 kW WALL HUNG HEAT PUMP 11 EER DS DOOR SWITCH - HVAC AS 34" FLEX CONDUIT FROM DOOR FRAME <br /> REQUIRED 18/2 TO HVAC UNIT <br /> HVAC CONTROLS 1 THERMOSTAT - BARD #8403-060 WALL HUNG HVAC UNIT AS REQUIRED SEE MECH SCHEDULE AND CALCS <br /> 1 TEMP SENSOR - BARD #8403-062 Q HVAC THERMOSTAT 48" 4" SQUARE BOX w/SINGLE GANG MR <br /> 18AWG STAT WIRE <br /> LIGHTING 3 2 x 4 LED TROFFER- nLIGHT ENABLED- 6000 LUMEN- 48 WATTS- 4DOOK nLIGHT ENABLED LED TROFFER 48 VA EACH <br /> LITHONIA - 2BLT4 60L ADPT EZ1 LP840 N100 NES7ADCX PWS1836 w/INTEGRAL SENSORS CEILING 6000 LUMEN EACH <br /> 14 WATT LED WITH VANDAL RESISTANT COVER AND INTEGRAL PHOTO CELL. I-Q LED WALL PACK 84" 14 VA EACH <br /> 1 CONTROLLED BY 7 DAY PROGRAMMABLE WALL TIMER FIELD SET FOR <br /> BUSINESS HOURS. LITHONIA - OVWPLED4OK12DPEDDBHP17M4 I—f EXHAUST FAN - WALL MOUNT SEE VA EACH <br /> �] 270 CFM - BROAN 50B A-3.1 _ <br /> EXHAUST FAN 3 270 CFM BROAN 508 - SWITCHED WITH LIGHTS IN RESTROOM ® REMOTE SENSOR 48• t4" SQUARE BOX w/SINGLE GANG MR <br /> 18AWG SHIELDED STAT WIRE <br /> 12-8-21 PRELIM REVIEW-DG LDG COPYRIGHT 2021,BLAZER INDUSTRIES,INC. MOBILE Approved forConst: Job No: 20080 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY ADARR for: <br /> OF BLAZER INDUSTRIES,INC.AND SHALL File Copy: <br /> NOT BE REPRODUCED,USED,OR DISCLOSED 10x46 port of Everett - Norton Expansion <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE INDUSTRIES,INC. Drawn By: LDG <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. P.o.Box.29g <br /> es www.ewierind.com WA Pacific Mobile Everett,WA <br /> �� e45 Olney SL ■ Aumsville,Oft 97325-0489 Issue Date: 12-8-21 <br />