Laserfiche WebLink
PACKAGE *SPVU* HIGH EFFICIENCY WALL MOUNT HEAT PUMP — SCHEDULE <br /> SIN DIN <br /> DO FAN SENSIBLE HEATING HEAT CONNECTION <br /> BLOWER BLOWER EFFICIENCY VENTIL COOLING COOLING CAPACITY HEATING HEAT STRIPS <br /> _ UNIT BARD UNIT UNIT MOTOR AIRFLOW SPEED BLOWER GRADE VENTIL (FA) FILTER OU1000R ENTERING ENTERING CAPACITY CAPACTY Qdegs COP UNIT UNIT STRIPS OUTPUT MCA MOCP UNIT <br /> TAG UNIT MODEL NUMBER SIZE OTY TYPE CFM SETTING HP (EEG) DEVICE CFM TYPE EER (08)TEMP (D8)TEMP (W43)TEMP STUN ITUH STUN 47dege HERTZ VOLTS PHASE KW BNH AMPS AMPS WGT ADDITIONAL NOTES <br /> HP-1 W48HC—A15ZP4XXR 4.a 1 ECM 1585 MED 3/4 -- ECON --- MERV-8 11 95 80 67 48.330 W.679 41,378 3.3 60 240 1 15 51,19E 87 90 505 <br /> CCU <br /> ADDITIONAL NOTES:1—CAPACITY LISTED ABOVE ARE IN ACCORDANCE NTH ANS/ARI STANDARD 39D-2003 FOR SPVU(SINGLE PACKAGE VERTICAL UNITS) Seauenae Of ooerailon: <br /> 2—COMPLIES WITH EFFICIENCY REQUIREMENTS OF ANSI/ASHRAE/IESNA 9MI_2015 1— Upon a Cooling call from the room thermostat the unit will be in mechanical cooling <br /> 3—BARD THERMOSTAT(8403-060),7—DAY PROGRAMMABLE mode. <br /> 4—BARD INDOOR REMOTE SENSOR.(5403-062) 2—Upon a heating call from the room thermostat the unit will be in mechanical heating, <br /> 5—DELETED 2nd stage heat strips will come on if the room temperature drops below <br /> 6—HEAT STRIPS KIT WITH CIRCUIT BREAKER its setpoint and during defrost. <br /> 7—DELETED 3— DELETED <br /> 8—2-PLEATED FILTER,MERV-8 4— These modes with keep repeating and required by the thermostat. <br /> PLENUM VA R I F I CAT I O N 9—UNIT COLOR IS`BUCKEYE GRAY` 5 If this unit is equipped with a exterior door shut dawn kit the unit mechanical system <br /> 10—OUTDOOR THERMOSTAT SET AT 400EC'S k LAC CONTROL(R)CONTROL portion <br /> io shut down pera the exterior has been open for it minutes.The Ventilation <br /> 11-DELETED portion w01 keep operating.Once the door doses the unit will restart If there Is still <br /> o call from the thermostat. <br /> 12—(BSDRMER)KIT—PROVIDES A MEWS ON SHUTTING DOWN OF THE MECHANICAL COOLING AND HEATING SYSTEM,VENTILATION CONTINUES TO OPERATE,NA EXTERIOR DOOR SNITCH(OPTIONAL) <br /> SCALE:1/2"=V-O" <br /> M. 70 REFER To it STMJ.ATI0N INMUCTIONS FOR START UP AND EQUIPMENT SET <br /> M. To CHECK SITE VOLTAGE AND SET CORRECT TAP ON TRAHWORMER <br /> » M.C.70 SET AND PROGRAM THERMOSTAT PER CUSTOMERS 1EauIROJTJrs <br /> » M.G To SET ANa DIED(ECON0w—ANO VE 11-0N PIE PRO.ECT REQuIREMOITS <br /> O O <br /> MECHANICAL NOTES: RELIEF VENT WITH <br /> BACKDRAFT DAMPER <br /> WA - 2018 IMC WAC AND 2018 WSEC TYP. OF 4 <br /> 1. VENTILATION PROVIDED VIA NATURAL VENTILATION IN ACCORDANCE WITH IMC SECTION 402 IN O /i <br /> LIEU OF DOAS REQUIREMENTS. [WSEC SECTION C 403.3.5 EXCEPTION 1] 4 TON 15 kW <br /> 2. MECHANICAL EQUIPMENT INSTALLATION IN OR ON THIS BUILDING SHALL BE IN ACCORDANCE WITH WALL HUNG <br /> THE REQUIREMENTS OF IMC WAC CHAPTER 6 UNLESS OTHERWISE EXEMPTED. HEAT PUMP <br /> 3. DUCT MATERIAL IS 26 GA. GALVANIZED WITH 2.2"FSK INSULATION. DUCTWORK SHALL BE <br /> SUPPORTED. [IMC WAC SECTION 6031 12 <br /> 4. ROUND FLEX DUCT SHALL BE UL LISTED CLASS 1, STANDARD 181 - FACTORY MADE AIR TO <br /> DUCTSAND AIR CONNECTORS.THE MINIMUM THERMAL PERFORMANCE SHALL BE AT R-6, AND <br /> MEASURED IN ACCORDANCE WITH ATSM C 518 OR ATSM C 177 AT 75DEG F MEAN 12 <br /> TEMPERATURE. INSTALLATIONSHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION <br /> INSTRUCTIONS. <br /> 5. MATERIAL IN DUCTS SHALL HAVE A FLAME SPREAD INDEX OF LESS THAN 25, SMOKE PLENUM #PWS134 <br /> DEVELOPMENT OF 50. [IMC SECTION 602] <br /> 6. LOW PRESSURE DUCT SYSTEMS SHALL HAVE LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS <br /> AND CONNECTIONS OF SUPPLY AND RETURN DUCTS AND PLENUMS SECURELY FASTENED AND 6 <br /> SEALED WITH WELDS, GASKETS, MASTICS (ADHESIVES), MASTIC-PLUS EMBEDDED-FABRIC WALL MOUNTED <br /> SYSTEMS OR APPROVED TAPES INSTALLED IN ACCORDANCE WITH IMC WAC SECTION 603.9. WALL MOUNTED EXHAUST FAN <br /> 7. DUCT INSULATION SHALL COMPLY WITH IMC WAC SEC 604. EXHAUST FAN TYP. OF 3 <br /> B. WHEN ISOLATION SLEEVES ARE USED AT LINE CONNECTIONS TO PLENUMS, THEY SHALL COMPLY TYP. OF 3 <br /> WITH IMC WAC CHAPTER 6. <br /> 9. IF DIFFUSERS HAVE NO MANUAL DAMPERS, USE FLOW CONTROL AT WYES. TYPICAL AS NOTED ON TYPICAL DOOR SWITCH WITH MECHANICAL PLAN <br /> PLAN. TIME DELAY WIRING FOR HEAT PUMPS <br /> 10. MINIMUM OUTSIDE AIR VENTILATION PER IMC WAC TABLE 403.3.1.1. THIS DRAWING IS SHOWN WITH A JUMPER WIRE SCALE:1/4" 1'-0' <br /> INSTALLED ON TERMINAIS e1 TO 02'DOOR <br /> 11. OUTSIDE AIR DAMPERS SHALL COMPLY WITH WSEC, SECTION C403.7.8. SWITCH JUMPER'WIRE-REMOVE JUMPER WHEN <br /> DOOR SWITCH 15 INSTALLED.WIRED AS SHOWN. <br /> 12. ALL NEW SYSTEMS REQUIRE ECONOMIZERS UNLESS EXEMPTED BY EXCEPTIONS. [WSEC SECTION <br /> 403.5] 0 0 <br /> 13. DOOR SWITCH CONTROLS SHALL BE INSTALLED IN ACCORDANCE WITH WSEC 403.4.1.6 AT ALL r---------1L <br /> DOORS THAT OPEN TO THE OUTDOORS. j y� RT MECHANICAL SYMBOLS <br /> 14. MECHANICAL DRAW NGS SHOW DUCTWORK SIZES TO BE CLEAR INSIDE DIMENSION. --------2 29 <br /> I ®G SYMBOL DESCRIPTION <br /> 15. ELECTRICIAN MUST VERIFY ALL ELECTRICAL REQUIREMENTS AND LOCATIONS. I I 3 3® ®C <br /> 16.CONTRACTOR SHALL ARRANGE ALL HVAC UNITS AND ASSOCIATED ITEMS FOR ACCESS 4® ®CLEARANCES. E® ®Y 2'x2' SUPPLY AIR DIFFUSER <br /> 17. THERMOSTAT SCHEDULING TO BE PERFORMED ON SITE BY OTHERS. i °® L® ®Y1 =____= EXHAUST FAN DUCT/RELIEF AIR GRILLE DUCT <br /> 18. ALL HVAC EQUIPMENT LEAVES FACTORY WIRED FOR 240 VOLT OPERATION. I <br /> 19.THE ACCEPTABLE OPERATING RANGE FOR THE 240V& 208V TAPS ARE: 7® DH® LB g RANGE EXHAUST FAN WITH HOOD <br /> TAP I I ® 01® 1 <br /> 240 253 -216isrAUEo °O 0 14"x14" RELIEF VENT WITH BACKDRAFT DAMPER <br /> I I WIRES ADD NEW UNITLOWVOLTAGE <br /> 2D6 22D-167 I I TERMINAL TERMINAL BLOCK <br /> I I — <br /> 20.SITE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR MAKING SURE THE RIGHT TAP IS I I BARD —X SUPPLY DUCT w/DIAMETER INDICATORBLOCK <br /> CONNECTED FOR THE APPLIED SITE VOLTAGE. I sSDr4Q1 <br /> THERMOSTAT <br /> 21. AIR FILTERS IN HVAC UNITS OR SYSTEMS ARE TO BE CHANGED EVERY 30 DAYS BY OTHERS ON �Dao6 swTCH(FIELDIS <br /> WHEN DOOR <br /> SITE. I SWITCH N THE <br /> PO ODR <br /> Li Pl THE OPEN POSITION <br /> 22.REGISTER AIR FLOW TEST AND BALANCE OF HVAC SYSTEM TO BE PROVIDED AND PERFORMED BY 1 - SWRCH IS NTHEGEOWHENDOOR RS REMOTE SENSOR <br /> OTHERS ON SITE WHEN REQUIRED. L___ IswTHECLos6DPosrloN <br /> 23.HVAC SITE CONTRACTOR IS RESPONSIBLE FOR BALANCING THE SYSTEM. BALANCING SHALL BE IN THISKRWILLCOMPLY WRHWSECCIO3 .1.6 <br /> ACCORDANCE WITH IMC WAC 403.3.1.5. CUSTOMER <br /> TOVCR APPROVAL <br /> PDDOVAL <br /> 11 APPROVED <br /> ❑APPROVED EXCEPT AS NOTED PRELIMINARY <br /> ❑ REVISE AS NOTED AND RESUBMIT <br /> APPROVED By Dote NOT FOR CONSTRUCTION <br /> 12-7-21 PRELIM REVIEW-DG LOG COPYRIGHT 2021,BLAZER INDUSTRIES,INC. MOBILE ADARR fO!'. Approved for Const JObNo: 20080 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY <br /> OF BLAZER INDUSTRIES,INC.AND SHALL ■■ r File Copy: <br /> NOT BE REPRODUCED,USED,OR DISCLOSED 10x46 port of Everett - Norton Expansion <br /> --blINDUS hrd.NC. <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE RO.BOX 4 t. wwwblazennd.com Drawn By: LOG <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. �� 945Omey sl. ■ Aumsville,OR 97325-0489 WA Pacific Mobile Everett,WA Issue Date: 12-7-71 <br />