My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2600 FEDERAL AVE 2022 PORT OF EVERETT Plans 2025-09-11 (2)
>
Address Records
>
FEDERAL AVE
>
2600
>
PORT OF EVERETT
>
Plans
>
2600 FEDERAL AVE 2022 PORT OF EVERETT Plans 2025-09-11 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2025 8:45:28 AM
Creation date
9/11/2025 8:44:47 AM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
2600
Tenant Name
PORT OF EVERETT
Permit
B2201-015
Year
2022
Notes
MODULAR BREAKROOM BUILDING WITH ACCESS RAMPS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8" 12 GA. HANGER 8" BERC2 CLIP <br /> 4CLIP MAX. WIRE 4'-0" o.c. MAX. <br /> POP RIVET MAIN RUNNER (SEE DETAIL 1) <br /> WALL OR CROSS TEE WALL <br /> CROSS TEE CROSS TEE ANGLE ACOUSTICAL <br /> BOARD WALWALL 1/8" POP RIVET (NO POP RIVETS) ANGLE <br /> PROVIDE 3/4" SPACE AT WALL <br /> MEMBER AT OPPOSING WALL <br /> WALL ANGLE (ATTACHED WALLS) (UNATTACHED WALLS) <br /> 8 x 1/2" ROUND WASHER HEAD TEKWCREW (SELF- TAPPING) ATTACHED WALL HANGER AND PERIMETER WIRES MUST BE PLUMB WITHIN 1:6 UNLESS <br /> NOTE: SCREW IS I�TIGHTENED DOWN <br /> AGAINST BERC2 CLIP (TWO ADJACENT WALLS) COUNTER SLOPING WIRES ARE PROVIDED <br /> LATERAL-FORCE BRACING- <br /> UNATTACHED WALL SEISMIC BERC2 CLIP IS THE USE OF VERTICAL STRUTS AND SPLAY WIRES. <br /> (TWO ADJACENT WALLS) -FACTORY INSTALLED AT TWO ADJACENT WALLS. CEILING AREAS OF 1000 SQ.FT. OR LESS SHALL BE EXEMPT FROM <br /> -SCREW TIGHTENED FOR SHIPPING IN ROOMS WHERE LATERAL-FORCE BRACING REQUIREMENTS. <br /> CEILING CROSSES MOD LINE, LOOSEN SCREW ON SITE CEILINGS WITH INTERSTITIAL SPACE LESS THAN 12" TO FRAMING <br /> BY SET UP CREW ARE NOT REQUIRED TO HAVE LATERAL-FORCE BRACING. <br /> -NOT REQUIRED FOR CEILINGS LESS THAN OR EQUAL SEISMIC SEPARATION JOINTS: <br /> TO 144 SF AND SURROUNDED BY WALLS CONNECTED TO ALL CONTINUOUS CEILING AREAS EXCEEDING 2500 SQ.FT. SHALL <br /> THE STRUCTURE ABOVE. HAVE A SEISMIC SEPARATION JOINT. <br /> -SOURCES: ASCE 7-16 SECTION 13.5.6 EXCEPTION 1, <br /> 1 SECTION SEISMIC ATTACHMENT AT WALLS 2 STANDARD T-BAR DETAIL <br /> N.T.S. [ARMSTRONG SEISMIC 'Rx' SUSPENSION SYSTEM (ESR 1308)] N.T.S. <br /> OSEISMIC BERC CUP <br /> -FACTORY INSTALLED SUSPENDED T-BA <br /> 2 x 2 SUPPLY 2 x 2 RETURN AT TWO ADJACENT WALLS CEILING GRID <br /> AIR DIFFUSER AIR GRILLE SEE DETAIL (1/A-5) SEE DETAIL (2/A-5) <br /> O <br /> no <br /> O O <br /> O <br /> REFLECTED CEILING PLAN <br /> SCALE:1/4"=P-0" <br /> CUSTOMER APPROVAL <br /> ❑APPROVED <br /> STATEMENT OF SPECIAL INSPECTIONS ❑APPROVED EXCEPT AS NOTED <br /> The materials,systems,components,and work required to have special ❑ REVISE AS NOTED AND RESUBMIT <br /> inspections are listed below. Inspections will be completed by the APPROVED By Date <br /> engineer of record. PRELIMINARY <br /> Special inspection for suspended ceiling system: <br /> Periodic inspection of the suspended ceiling system to verify that it <br /> complies with ESR-1308. NOT FOR CONSTRUCTION <br /> COPYRIGHT 2021,BLAZER INDUSTRIES,INC. MOBILE BREAK ROOM for: Approved f°rC°nst dob No: 2008i <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY <br /> OF BLAZER INDUSTRIES,INC.AND SHALL ■■ File Copy: <br /> NOT BE REPRODUCED,USED,OR DISCLOSED 10 X 30 port of Everett - Norton Expansion <br /> Yr <br /> DUSTRIES, <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THEDrawn ay: LDG = <br /> On.,nww.blazerfnd.mmINC. <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. ME 9as Olney s� ■ Aumsvllle,OR97325-0489 VVA Pacific Mobile Everett,VUA Iesue Date: 11-29-21 <br />
The URL can be used to link to this page
Your browser does not support the video tag.