Laserfiche WebLink
QA 12 Y4 B PACKAGE sSPW'HIGH EFFICIENCY WALL MOUNT HEAT PUMP - SCHEDULE <br /> I � <br /> DD FAN SENSIBLE HEATING HEAT CONNECTION <br /> BLOWER BLOWIER EFFICIENCY VENTIL OOCLING COOLING CAPACITY HEATING HEAT STRIPS <br /> TAME UNIT YODEL BARDNUF®ER 5� OTY TYPE UNIT UNIT MOTOR 'U CFH SETTEJG RFLOW SPEED eLHOP� ( C DEV7CE VENTIL (6M TYPE fFR (DB FILTER WKELP (DB)'IEMNP (WBw)lE]IPBTERING N� TUt CAPACITY 4B711�1He 4 COPUNIT 1R11T 57R8'S W1PI1T MCA MOW LINK <br /> e1y� HERTZ VGLTS PHASE KW L11UH AMPS AMPS WGT ADDITIONAL N016 <br /> O HP-1 WI8H8-AD4ZP4XXR 1.5 1 ECM 709 No 1/3 - ECON MERV-8 11.30 95 80 87 15.136 14,290 ie,B00 15 e0 240 1 OB 27.304 57 80 325 1.2,3,4,48.7.9,10,11 <br /> 1 I <br /> ADDITIONAL NOTES SEQUENCE OF OPERATION: <br /> 1-CAPACITY LISTED ABOVE ARE IN ACCORDANCE WITH ANS/ARM STANDARD 300-2003 FOR SPW(SINGLE PACKAGE VERTICAL UNITS) <br /> 2-COMPLIES WITH EFFICIENCY REOUIRENENTS OF ANSI ASI-RAE/1ESNA 90.1-201& <br /> 3-SAID THERMOSTAT�e4o�080.7-DAY PROGRAMMABLE 1-UPON A COOLING CALL FROM THE ROOM THERMOSTAT THE UNIT WILL BE IN ECONOMIZER qi MECHANICAL <br /> 4-BARD INDOOR REZ�GIE SENSOR.A8403-087 COOLING MODE OR BOTH DEPENDING ON THE ECONOMIZER JADE CONTROLLER SETPOINTS. <br /> 5-BARD 002 SENSOR'SM3-087 2-UPON A HEATING CALL FROM THE ROOM THERMOSTAT THE UNIT WILL BE IN MECHANICAL HEATING AND THE <br /> 4-r PLEATED FILTER MERV-8 ECONOMIZER WILL BE DISABLE,2ND STAGE HEAT STRIPS WILL COME ON IF THE ROOM TEMPERATURE DROPS <br /> 5-UNIT COLOR IS'BUCKEYE(RAY- BELOW ITS SETPOINT AND DURING DEFROST. <br /> 8-HEAT STRPS NIT WITH CIRCUIT BREAKER 3-CO2 SENSOR TO CONTROL THE VENTILATION MODE THROUGH THE OCCUPY CONNECTION AS REQUIRED BY ITS <br /> 7-PRE INSTALLED OUTDOOR THERMOSTAT,SET AT 40DEIS 3 LAC CONTROL(R)OPT SET POINTS10-ECONOMM.WITH JADE CONTROLLER ENTHAPY/TEMP SENSOR <br /> PLENUM VA R I F I CAT I O N 11-MBSDRMER-TO ALLAOOVIDE A MEANS OF SHUTTING DOWN OF THE MECHANICAL HEATING AND AND COOLING SYSTEM.WA DOOR SWITCH ,-THESE MODES WITH KEEP REPEATING AND REQUIRED BY THE THERMOSTAT. <br /> MC To REAR TONSTALUl1GM TIISiMICTIGS FED STAIR UP Aso ECOIPMFNT sr. <br /> M. TO OECK SITE VOLTAGE AND SST ccw=TAP ON TRANgOEER. <br /> M.0 TO SET A PROGRAM THERMOSTAT PER OISTOERS IEalIfE1IXIS <br /> MC TO SET AND GEL1G EOONOICIER AND 140411LATION PIE PRGECT PEQUI Elm/R <br /> SCALE:1/2"=1'-0" <br /> O O <br /> PLENUM #PWR139 <br /> O <br /> ---- 10 1.5 TON 4 kW <br /> MECHANICAL NOTES: - WALL HUNG <br /> 1------- S- HEAT PUMP <br /> WA - 2018 IMC WAC AND 2015 WSEC "1020 CFM MAX <br /> 1. VENTILATION PROVIDED VIA NATURAL VENTILATION IN ACCORDANCE WITH IMC SECTION 402 IN S <br /> LIEU OF DOAS REQUIREMENTS. [WSEC SECTION C 403.3.5 EXCEPTION 1] S 8 <br /> 2. MECHANICAL EQUIPMENT INSTALLATION IN OR ON THIS BUILDING SHALL BE IN ACCORDANCE WITH <br /> THE REQUIREMENTS OF IMC WAC CHAPTER 6 UNLESS OTHERWISE EXEMPTED. <br /> 3. DUCT MATERIAL IS 26 GA. GALVANIZED WITH 2.2"FSK INSULATION. DUCTWORK SHALL BE <br /> SUPPORTED. [IMC WAC SECTION 603] Q PLENUM #PWS052 <br /> 4. ROUND FLEX DUCT SHALL BE UL LISTED CLASS 1, STANDARD 181 - FACTORY MADE AIR <br /> DUCTSAND AIR CONNECTORS.THE MINIMUM THERMAL PERFORMANCE SHALL BE AT R-6, AND O <br /> MEASURED IN ACCORDANCE WITH ATSM C 518 OR ATSM C 177 AT 75DEG F MEAN <br /> TEMPERATURE. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION <br /> INSTRUCTIONS.IN MECHANICAL PLAN- <br /> DEVELOPMENT <br /> 5. MATERIAUAL IN DUCTS SHALL HAVE A FLAME SPREAD INDEX DF LESS THAN 25, SMOKE <br /> OF 50. [IMC SECTION 602] <br /> SCALE:1!4"=1'-0" <br /> 6. LOW PRESSURE DUCT SYSTEMS SHALL HAVE LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS <br /> AND CONNECTIONS OF SUPPLY AND RETURN DUCTS AND PLENUMS SECURELY FASTENED AND <br /> SEALED WITH WELDS, GASKETS, MASTICS (ADHESIVES), MASTIC-PLUS EMBEDDED-FABRIC MECHANICAL SYMBOLS <br /> SYSTEMS OR APPROVED TAPES INSTALLED IN ACCORDANCE WITH IMC WAC SECTION 603.9. <br /> 7. DUCT INSULATION SHALL COMPLY WITH IMC WAC SEC 504. SYMBOL DESCRIPTION <br /> 8. WHEN ISOLATION SLEEVES ARE USED AT LINE CONNECTIONS TO PLENUMS, THEY SHALL COMPLY ® 2'x2' SUPPLY AIR DIFFUSER <br /> WITH IMC WAC CHAPTER 6. <br /> 9. IF DIFFUSERS HAVE NO MANUAL DAMPERS, USE FLOW CONTROL AT WYES. TYPICAL AS NOTED ON TYPICAL DOOR SWITCH WITH 2'x2' RETURN AIR GRILLE <br /> PLAN. TIME DELAY WIRING FOR HEAT PUMPS <br /> 10. MINIMUM OUTSIDE AIR VENTILATION PER IMC WAC TABLE 403.3.1.1. THIS DRAWING IS SHOWN WRH A JUMPER WIRE <br /> INSTATED ON TERMINALS 01 TO n'DOOR -X- SUPPLY DUCT w/DIAMETER INDICATOR <br /> 11. OUTSIDE AIR DAMPERS SHALL COMPLY WITH WSEC, SECTION C403.7.8. SNITCH JUMPER'WRE.REMOVE JUMPER WHEN <br /> DOOR SW RCH IS INSTATED.WIRED AS SHOWN. <br /> 12. ALL NEW SYSTEMS REQUIRE ECONOMIZERS UNLESS EXEMPTED BY EXCEPTIONS. [WSEC SECTION O THERMOSTAT <br /> 403.5] O O <br /> 13. DOOR SWITCH CONTROLS SHALL BE INSTALLED IN ACCORDANCE WITH WSEC 403.4.1.6 AT ALL r---------'"- _a <br /> DOORS THAT OPEN TO THE OUTDOORS. i R e 94­43RT Natural Ventilation rates per IMC Section 402 <br /> 14. MECHANICAL DRAWINGS SHOW DUCTWORK SIZES TO BE CLEAR INSIDE DIMENSION. I r 2 WZN ®G <br /> I I room#1 name Az(sf) 4%(sf) openings check notes <br /> 15. ELECTRICIAN MUST VERIFY ALL ELECTRICAL REQUIREMENTS AND LOCATIONS. i i 3® 3® ®0 - Break Room 238 9.5 29.93 OK <br /> 16. CONTRACTOR SHALL ARRANGE ALL HVAC UNITS AND ASSOCIATED ITEMS FOR ACCESS ® N NY <br /> CLEARANCES. i i E�® <br /> 17. THERMOSTAT SCHEDULING TO BE PERFORMED ON SITE BY OTHERS. <br /> L® ®Y1 DOAS is not provided due to the exception for areas with natural ventilation under 2018 WSEC C403.3.5 Exception 1. <br /> 19. <br /> . THE ACCEPTABLE OPERATING RANGE FOR THE 240V&208V TAPS ARE:ALL HVAC EQUIPMENT LEAVES FACTORY WIRED FOR 240 VOLT OPERATION. i i EN® DH N Natural Ventilation is provided per 20181MC Section 402.1,402.2 and 402.3. <br /> 1 I <br /> T <br /> TAP RANGE FIrTD 4N 019 RB11 <br /> Section 402.1-The Natural Ventilation shall be provided through the windows and exterior doors(SEE PLAN SHEETA-1 <br /> 240 253 -216 i INSTALLED 0 O for location and sizing information). <br /> RES ADO NEW UNIT LOW VOLTAGE <br /> 208 220-187 I TERMIRIAL TERMINAL BLOCK <br /> 20.SITE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR MAKING SURE THE RIGHT TAP IS i BARD <br /> CK Section 402.2-The minimum openable area ofthese means of natural ventilation,shall meetthe 4%offloorarea <br /> CONNECTED FOR THE APPLIED SITE VOLTAGE. M7421 <br /> requirement.The exterior windows and doors provide direct natural ventilation to the spaces at the perimeterofthe <br /> 21. AIR FILTERS IN HVAC UNITS OR SYSTEMS ARE TO BE CHANGED EVERY 30 DAYS BY OTHERS ON �D- SANSWrITCHSOPE WHEN O) <br /> SITE. I �L SWRCH IS OPEN WHEN DOOR <br /> I 61N THE OPEN POSITION <br /> 22.REGISTER AIR FLOW TEST AND BALANCE OF HVAC SYSTEM TO BE PROVIDED AND PERFORMED BY - IN <br /> LS IN THE CLOSED POSRION <br /> OTHERS ON SITE WHEN REQUIRED. L----- <br /> 23.HVAC SITE CONTRACTOR IS RESPONSIBLE FOR BALANCING THE SYSTEM. BALANCING SHALL BE IN THISKIT WILL COMPLY WITH WSEC G03A.1.8 CUSTOMER APPROVAL <br /> ACCORDANCE WITH IMC WAC 403.3.1.5. <br /> ❑APPROVED <br /> ❑APPROVED EXCEPT AS NOTED PRELIMINARY <br /> El REVISE AS NOTED AND RESUBMIT <br /> APPROVED By Date NOT FOR CONSTRUCTION <br /> COP RIGHTMATER 2021, <br /> I1,THE ER INDUSTRIES, <br /> PROPERTY MOBILE BREAK ROOM for. ApproVed for COnst Job No: 20081 <br /> THISOF BLAZER INDUSTRIES,INC.AND SHALL ■■ r File Copy: <br /> TO BE OTHERS <br /> AUTHORIZED <br /> DISCLOSED 10 x 30 port of Everett - Norton Expansion <br /> TD OTHERS EXCEPT AS AUTHORIZED BY THE INDUSTRIES,INC. Drawn By: LDG I� <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. P.O.aox4e9 www.5lu_'ind.wm WA Pacific Mobile Everett,WA <br /> �� 99501ney St. ■ Aumsville.OR 97325-0489 Issue Date: 11-29-21 <br />