Laserfiche WebLink
8" 12 GA. HANGER 8.. <br /> BERC2 CLIP <br /> 4CUP MAX. WIRE 4'-0" o.c. MAX. <br /> POP RIVET MAIN RUNNER (SEE DETAIL 1) <br /> WALL OR CROSS TEE WALL <br /> CROSS TEE CROSS TEE ANGLE ACOUSTICAL <br /> BOARD WA L <br /> WALL 1/8' POP RIVET (NO POP RIVETS ANGLE <br /> PROVDE 3/4" SPACE AT WALL <br /> MEMBER AT OPPOSING WALL <br /> WALL ANGLE (ATTACHED WALLS) (UNATTACHED WALLS) <br /> #8 x 1/2" ROUND WASHER HEAD TEKWCREW (SELF— TAPPING) ATTACHED WALL HANGER AND PERIMETER WIRES MUST BE PLUMB WITHIN 1:6 UNLESS <br /> NOTE: SCREW IS C TIGHTENED DOWN <br /> AGAINST BERC2 CLIP (TWO ADJACENT WALLS) COUNTER SLOPING WIRES ARE PROVIDED <br /> LATERAL—FORCE BRACING: <br /> UNATTACHED WALL SEISMIC BERC2 CLIP IS THE USE OF VERTICAL STRUTS AND SPLAY WIRES. <br /> (TWO ADJACENT WALLS) —FACTORY INSTALLED AT TWO ADJACENT WALLS. CEILING AREAS OF 1000 SQ.FT. OR LESS SHALL BE EXEMPT FROM <br /> —SCREW TIGHTENED FOR SHIPPING IN ROOMS WHERE LATERAL—FORCE BRACING REQUIREMENTS. <br /> CEILING CROSSES MOD LINE, LOOSEN SCREW ON SITE CEILINGS WITH INTERSTITIAL SPACE LESS THAN 12" TO FRAMING <br /> BY SET UP CREW ARE NOT REQUIRED TO HAVE LATERAL—FORCE BRACING. <br /> —NOT REQUIRED FOR CEILINGS LESS THAN OR EQUAL SEISMIC SEPARATION JOINTS: <br /> TO 144 SF AND SURROUNDED BY WALLS CONNECTED TO ALL CONTINUOUS CEILING AREAS EXCEEDING 2500 SQ.FT. SHALL <br /> THE STRUCTURE ABOVE. HAVE A SEISMIC SEPARATION JOINT. <br /> —SOURCES: ASCE 7-16 SECTION 13.5.6 EXCEPTION 1, <br /> 1 ESEISMIC ATTACHMENT AT WALLS 2 STANDARD T-BAR DETAIL <br /> N.T.S. [ARMSTRONG SEISMIC 'Rx SUSPENSION SYSTEM (ESR 1308)) N.T.S. <br /> OSEISMIC BERC CUP 1 <br /> —FACTORY INSTALLED SUSPENDED T—BA <br /> 2 x 2 SUPPLY 2 x 2 RETURN AT TWO ADJACENT WALLS CEILING GRID <br /> AIR DIFFUSER TAIR GRILLE SEE DETAIL (1/A-5) SEE DETAIL (2/A-5) O <br /> A <br /> 7F z <br /> O O O <br /> .1 1 <br /> 11 1 <br /> I I I � � I I I LE Li <br /> 11 1 > <br /> REFLECTED CEILING PLAN <br /> SCALE:1/4"=T-0" <br /> CUSTOMER APPROVAL <br /> ❑APPROVED <br /> STATEMENT OF SPECIAL INSPECTIONS ❑APPROVED EXCEPT AS NOTED <br /> The materials,systems,components,and work required to have special ❑ REVISE AS NOTED AND RESUBMIT <br /> inspections are listed below. Inspections will be completed by the APPROVED By Date <br /> engineer of record.Special inspection for suspended ceiling system: PRELIMINARY <br /> Periodic inspection of the suspended ceiling system to verify that it <br /> complies withESR-1308. NOT FOR CONSTRUCTION <br /> COPYRIGHT 2021,BLAZER INDUSTRIES,INC. MOBILE BREAK ROOM for: Approved for Const Jot No: 20081 <br /> THIS MATERIAL IS THE S,CLL INC. NE SHALL tt <br /> OF BLAZER INDUSTRIES.INC.AND SHALL ■■ � 10 x 30 port of Everett - Norton Expansion File Copy: <br /> NOT BE REPRODUCED,USED,OR DISCLOSED <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE INDUSTRIES,INC. Drawn By: LDGA=5 <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. R.O.BOX489 www.blazerind.com WA Pacific Mobile Everett,WA <br /> �� 945 Olney SL ■ Aumsvill,OR 97325-0489 Issue Date: 11-29-21 <br />