B" 12 GA. HANGER a- <br /> BERC2 CLIP <br /> BERC2 CLIP MAX. WIRE 4'-0" O <br /> .C. MAX. <br /> POP RIVET MAIN RUNNER (SEE DETAIL 1) <br /> WALL _OR CROSS TEE WALL <br /> O� CROSS TEE CROSS TEE ANGLE ACOUSTICAL <br /> BOARD WALL <br /> WALL 1/8" POP RIVET (NO POP RIVETS) ANGLE <br /> PROVIDE 3/4" SPACE AT WALL <br /> MEMBER AT OPPOSING WALL <br /> WALL ANGLE (ATTACHED WALLS) (UNATTACHED WALLS) <br /> #8 x 1/2" ROUND WASHER HEAD TEK <br /> WALL ANGLE SCREW (SELF— TAPPING) ATTACHED WALL HANGER AND PERIMETER WIRES MUST BE PLUMB WITHIN 1:6 UNLESS <br /> NOTE: SCREW IS �TIGHTENED DOWN <br /> AGAINST BERC2 CLIP (TWO ADJACENT WALLS) COUNTER SLOPING WIRES ARE PROVIDED <br /> LATERAL—FORCE BRACING <br /> UNATTACHED WALL SEISMIC BERC2 CLIP IS THE USE OF VERTICAL STRUTS AND SPLAY WIRES. <br /> (TWO ADJACENT WALLS) —FACTORY INSTALLED AT TWO ADJACENT WALLS. CEILING AREAS OF 1000 SQ.FT. OR LESS SHALL BE EXEMPT FROM <br /> —SCREW TIGHTENED FOR SHIPPING IN ROOMS WHERE LATERAL—FORCE BRACING REQUIREMENTS. <br /> CEILING CROSSES MOD LINE, LOOSEN SCREW ON SITE CEILINGS WITH INTERSTITIAL SPACE LESS THAN 12" TO FRAMING <br /> BY SET UP CREW ARE NOT REQUIRED TO HAVE LATERAL—FORCE BRACING. <br /> —NOT REQUIRED FOR CEILINGS LESS THAN OR EQUAL SEISMIC SEPARATION JOINTS: <br /> TO 144 SF AND SURROUNDED BY WALLS CONNECTED TO ALL CONTINUOUS CEILING AREAS EXCEEDING 2500 SQ.FT. SHALL <br /> THE STRUCTURE ABOVE. HAVE A SEISMIC SEPARATION JOINT. <br /> —SOURCES: ASCE 7-16 SECTION 13.5.6 EXCEPTION 1, <br /> ASTM E580 SECTION 1.4 <br /> 1 SEISMIC ATTACHMENT AT WALLS 2 STANDARD T-BAR DETAIL <br /> N.T.S. [ARMSTRONG SEISMIC 'Rx SUSPENSION SYSTEM (ESR 1308)] N.T.S. <br /> OSEISMIC BERC CUP O <br /> SUSPENDED T—BAR —FACTORY INSTALLED <br /> CEILING GRID AT TWO ADJACENT WALLS 2 x 2 SUPPLY <br /> SEE DETAIL (2/A-5) SEE DETAIL (1/A-5) AIR DIFFUSER <br /> O <br /> O O z O O <br /> O <br /> WALL MOUNTED <br /> EXHAUST FAN <br /> TYP. OF 3 <br /> REFLECTED CEILING PLAN <br /> SCALE:114"=1'-0" <br /> CUSTOMER APPROVAL <br /> ❑APPROVED <br /> STATEMENT OF SPECIAL INSPECTIONS ❑APPROVED EXCEPT AS NOTED <br /> The materials,systems,components,and work required to have special ❑ REVISE AS NOTED AND RESUBMIT <br /> inspections are listed below. Inspections will be completed by the APPROVED By Date <br /> engineer of record.Special inspection for suspended ceiling system: PRELIMINARY <br /> Periodic inspection of the suspended ceiling system to verify that it <br /> complies withESR-1308. F NOT FOR CONSTRUCTION <br /> 12-7-21 PRELIM REVIEW-DG LDG COPYRIGHT 2021,BLAZER INDUSTRIES.INC. MOBILE ADARR IOC. Approved for Const: Job No: 20080 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY <br /> NOTOF BE <br /> INDUSTRIES.INC.AND OR <br /> �� 10x46 port of Everett - Norton Expansion F'le Copy: <br /> NOT BE REPRODUCED,USED.OR DISCLOSED �� iNousTR AR <br /> Drawn By: LOG <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE i p,0.BOX 689 wwwAlazanntlmm <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. �� 9g501ney SL ■ Aumsvllk,OR97325-0489 WA Pacific Mobile Everett,WA Issue Date: i2-7-21 <br />