2600 FEDERAL AVE 2022 PORT OF EVERETT Plans 2025-09-11 (3)
>
Address Records
>
FEDERAL AVE
>
2600
>
PORT OF EVERETT
>
Plans
>
2600 FEDERAL AVE 2022 PORT OF EVERETT Plans 2025-09-11 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2025 9:19:41 AM
Creation date
9/11/2025 9:18:07 AM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
2600
Tenant Name
PORT OF EVERETT
Permit
B2201-016
Year
2022
Notes
MODULAR GUARDSHACK ON TOP OF CONCRETE FOUNDATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I B i A <br /> PACKAGE *SPVU* HIGH EFFICIENCY WALL MOUNT HEAT PUMP - SCHEDULE <br /> N POIN <br /> DD FAN SENSIBLE HEATING HEAT CONNECTION <br /> BLOWER BLOWER EFF`CIENCY VENTIL COOLING COOLING CAPACITY HEATING HEAT STRIPS <br /> UNIT BARD UNIT UNIT MOTOR AIRFLOW SPEED BLOWER GRADE VENTIL (FA) FILTER OUTDOOR ENTERING ENTERING CAPACITY CAPACITY 47degs COP UNIT UNIT STRIPS OUTPUT MCA MOCP UNIT <br /> TAG UNIT MODEL NUMBER SIZE OTY TYPE CFM SETTING HP (FEG) DEVICE CFM TYPE EER (08)TEMP (DS)TEMP (WB)TEMP STUN STUN STUN 47dage HERTZ VOLTS PHASE KW STUN AMPS AMPS WGT ADDITIONAL NOTES <br /> HP-1 W48HC-A157P4XXR 4.0 1 ECM 1688 MED 3/4 ---- ECON _-__ MERV-8 11 95 8o 57 48,330 37,679 41,378 7.3 BO 240 1 15 51,195 87 90 505 <br /> r-- ---- --� ADDITIONAL NOTES <br /> I I $eauence at ooeratl0n: <br /> I I i-CAPACITY LISTED ABOVE ARE IN ACCORDANCE WITH ANS/ART STANDARD 390-2003 FOR SPW(SINGLE PACKAGE VERTICAL UNITS) <br /> 2-COMPUES WITH EFFICIENCY REOUIREMENTS OF ANSI/ASHRAE/IESNA 90.1-2016 1-Upon a Cooling call from the room thermostat the unit will be in mechanical cooling <br /> 3-BARD THERMOSTAT(8403-060),7-DAY PROGRAMMABLE mode. <br /> 4-BARD INDOOR REMOTE SENSOR(8403-062) 2- Upon a heating call from the room thermostat the unit will be in mechanical heating, <br /> 5-DELETED 2nd stage heat strips will come on If the room temperature drops below <br /> 6-HEAT STRIPS KIT WITH CIRCUIT BREAKER Its setpoint and during defrost. <br /> 7-DE ETm 3- DELETED <br /> e-2E PLEATED FILTER,MERV-8 4- These modes with keep repeating and required by the thermostat <br /> PLENUM VA R I F I CAT I O N 9-UNIT COLOR IS'BUCKEYE GRAY- 5- If this unit,9 equipped the a exterior door shut down kit the unit mechanical system <br /> 10-OUTDOOR THERMOSTAT SET AT 40DEG'S h LAC CONTROL(R)CONTROL will io shut down after the exterior has been open for it minutes.The here is still <br /> t1-DELETED portion will keep operating.Once the door closes the unit will restart If there is still <br /> 12-(BSDTIMER)KIT-PROVIDES A MEANS ON SHUTTING DOWN OF THE MECHANICAL COOLING AND HEATING SYSTEM,VENTILATION CONTINUES TO OPERATE,VIA EXTERIOR DOOR SWITCH(OPTIONAL) o call from the thermostat <br /> SCALE:1/2"=1'-0" <br /> M.G TO RHEA 10 INSTALLATION INSTRUCTIONS FOR START UP AND EQUIPMENT SET <br /> M.c TO OLEO(SIZE VOLTAGE AND SET CORRECT TAP ON TRANSmI <br /> M.0 To SEr AND P AM THERMOSTAT PER CUSTOIERS WWIREMENTS <br /> M.C.TO SET AHD 04E EWN ZER AND VENnLATIDN PRE PR0.ECT PEWIREMEIITS <br /> O O <br /> MECHANICAL NOTES: RELIEF VENT WITH <br /> BACKDRAFT DAMPER <br /> WA - 20181MC WAC AND 2018 WSEC TYP. OF 4 <br /> 1. VENTILATION PROVIDED VIA NATURAL VENTILATION IN ACCORDANCE WITH IMC SECTION 402 IN O ./ <br /> LIEU OF DOAS REQUIREMENTS. [WSEC SECTION C 403.3.5 EXCEPTION 1] 4 TON 15 kW <br /> 2. MECHANICAL EQUIPMENT INSTALLATION IN OR ON THIS BUILDING SHALL BE IN ACCORDANCE WITH WALL HUNG <br /> THE REQUIREMENTS OF IMC WAC CHAPTER 6 UNLESS OTHERWISE EXEMPTED. HEAT PUMP <br /> 3. DUCT MATERIAL IS 26 GA. GALVANIZED WITH 2.2"FSK INSULATION. DUCTWORK SHALL BE <br /> SUPPORTED. [IMC WAC SECTION 6031 1 2 <br /> 4. ROUND FLEX DUCT SHALL BE UL LISTED CLASS 1, STANDARD 181 - FACTORY MADE AIR VA <br /> TO <br /> DUCTSAND AIR CONNECTORS.THE MINIMUM THERMAL PERFORMANCE SHALL BE AT R-6, AND <br /> MEASURED IN ACCORDANCE WITH ATSM C 518 OR ATSM C 177 AT 75DEG F MEAN 12 <br /> TEMPERATURE. INSTALLATIONSHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION <br /> INSTRUCTIONS. <br /> 5. MATERIAL IN DUCTS SHALL HAVE A FLAME SPREAD INDEX OF LESS THAN 25. SMOKE PLENUM #PWS134 <br /> DEVELOPMENT OF 50. [IMC SECTION 6021 <br /> 6. LOW PRESSURE DUCT SYSTEMS SHALL HAVE LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS <br /> AND CONNECTIONS OF SUPPLY AND RETURN DUCTS AND PLENUMS SECURELY FASTENED AND B <br /> SEALED WITH WELDS, GASKETS, MASTICS (ADHESIVES), MASTIC-PLUS EMBEDDED-FABRIC WALL MOUNTED <br /> SYSTEMS OR APPROVED TAPES INSTALLED IN ACCORDANCE WITH IMC WAC SECTION 603.9. WALL MOUNTED EXHAUST FAN <br /> 7. DUCT INSULATION SHALL COMPLY WITH IMC WAC SEC 604. EXHAUST FAN TYP. OF 3 <br /> 8. WHEN ISOLATION SLEEVES ARE USED AT LINE CONNECTIONS TO PLENUMS, THEY SHALL COMPLY TYP. OF 3 <br /> WITH IMC WAC CHAPTER 6. <br /> 9. IF DIFFUSERS HAVE NO MANUAL DAMPERS, USE FLOW CONTROL AT WYES. TYPICAL AS NOTED ON TYPICAL DOOR SWITCH WITH MECHANICAL PLAN <br /> PLAN. TIME DELAY WIRING FOR HEAT PUMPS <br /> 10. MINIMUM OUTSIDE AIR VENTILATION PER IMC WAC TABLE 403.3.1.1. THIS DRAWING IS SHOWN WITH AJUMPER WIRE SCALE:1/4"=P-D" <br /> INSTALLED ON TERMINALS e1 TO e2'DOOR <br /> 11. OUTSIDE AIR DAMPERS SHALL COMPLY WITH WSEC, SECTION C403.7.6. 51YITCH JUMPER'WRE.REMOVE JUMPER WHEN <br /> DOOR SWITCH IS INSTALLED.WIRED AS SHOWN. <br /> 12. ALL NEW SYSTEMS REQUIRE ECONOMIZERS UNLESS EXEMPTED BY EXCEPTIONS. [WSEC SECTION <br /> 403.5] 0 0 <br /> 13.DOOR SWITCH CONTROLS SHALL BE INSTALLED IN ACCORDANCE WITH WSEC 403.4.1.6 AT ALL r---------1� <br /> DOORS THAT OPEN TO THE OUTDOORS. j R T MECHANICAL SYMBOLS <br /> -------- <br /> 14. MECHANICAL DRAWINGS SHOW DUCTWORK SIZES TO BE CLEAR INSIDE DIMENSION. i j-------DRAWINGS - <br /> 15. ELECTRICIAN MUST VERIFY ALL ELECTRICAL REQUIREMENTS AND LOCATIONS. i i 3® ®G SYMBOL DESCRIPTION <br /> 16. CONTRACTOR SHALL ARRANGE ALL HVAC UNITS AND ASSOCIATED ITEMS FOR ACCESS 3® MC <br /> CLEARANCES. i i 4® E® ®Y ® 2'x2' SUPPLY AIR DIFFUSER <br /> 17.THERMOSTAT SCHEDULING TO BE PERFORMED ON SITE BY OTHERS. L® ®Y1 =___-- EXHAUST FAN DUCT/RELIEF AIR GRILLE DUCT <br /> 1B. ALL HVAC EQUIPMENT LEAVES FACTORY WIRED FOR 240 VOLT OPERATION. I I <br /> 19. THE ACCEPTABLE OPERATING RANGE FOR THE 240V&208V TAPS ARE: j i T® OH® t6i <br /> EXHAUST FAN WITH HOOD <br /> TAP RANGE �� yy 01 <br /> 240 253 -216 i i INTA LED B® 0 14"x14" RELIEF VENT WITH BACKDRAFT DAMPER <br /> I I WIRES ADD NEW UNITLOWVOLTAGE <br /> 208 220-187 TERMINAL TERMINAL BLOCK <br /> - <br /> 20.SITE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR MAKING SURE THE RIGHT TAP IS I T BARD SUPPLY DUCT w/DIAMETER INDICATOR <br /> ONNECTED FOR THE APPLIED SITE VOLTAGE. 6 Kc <br /> -X <br /> CONNECTED <br /> THERMOSTAT <br /> 27.AIR FILTERS IN HVAC UNITS OR SYSTEMS ARE TO BE CHANGED EVERY 30 DAYS BY OTHERS ON �000R sw rcHS OPEN HE EO) <br /> SITE. i SWITCH ISTHE <br /> POSITION <br /> ISM THE OPEN WHEN <br /> DOOR <br /> 22.REGISTER AIR FLOW TEST AND BALANCE OF HVAC SYSTEM TO BE PROVIDED AND PERFORMED BY SWRISINTH.CLOSE ENDDDR RS REMOTE SENSOR <br /> I IS M THE CLOSED POSITION <br /> OTHERS ON SITE WHEN REQUIRED. L_____ <br /> 23.HVAC SITE CONTRACTOR IS RESPONSIBLE FOR BALANCING THE SYSTEM. BALANCING SHALL BE IN THIS KIT WILL COMPLY WITH WSEC C,1034,15 <br /> ACCORDANCE WITH IMC WAC 403.3.1.5. CUSTOMER APPROVAL <br /> ❑ APPROVED <br /> ❑APPROVED EXCEPT AS NOTED PRELIMINARY <br /> ❑ REVISE AS NOTED AND RESUBMIT <br /> APPROVED By Date NOT FOR CONSTRUCTION <br /> 12-7-21 PRELIM REVIEW-DG JB <br /> COPYRIGHT 2021,BLAZER INDUSTRIES,INC. MOBILE Approved for C-1, Job No: 20080 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY ADARR for: <br /> OF BLAZER INDUSTRIES,INC.AND SHALL ■■ File Copy: <br /> TO BE OTHERS EXCEPT <br /> AUTHORIZED <br /> RIZEDBYTED 10x46 port of Everett - Norton Expansion <br /> INDUSTRIES,INC. <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE P,O.BOX 46S www b,_Hnd.wm Drawn ey: LDG <br /> DATE REVISION WRITTEN PERMISSION OF BLAZER INDUSTRIES. �� 9as om"y 5L ■ Aumsville,OR 97325-0489 WA Pacific Mobile Everett,INA Issue Date: 12-7-21 MM 1 <br />