Laserfiche WebLink
7. Bath fan with 50CFM is now shown on the plan as well as the whole house <br /> "intermittent" fan location along with a fresh air inlet location. <br /> 8. GAS fireplace changed to electric (Fake fireplace). There is only one fireplace. <br /> 9. Electric panel location has been moved to allow for proper front and side <br /> clearances. <br /> 10. HW tank seismic anchor straps are now shown and noted on the plan. <br /> 11. Square footage of 5'x11' or S5 SQFT is noted at top of sheet #2 with calc's <br /> showing 17.6 square inches "required" per rafter space. (about 9" top and <br /> bottom) NOTE: Not sure if this is what you were requesting? <br /> 12. Porch roof was extended and is shown and "colored" for recognition on <br /> the drawings. <br /> 13. Insulation for slab and walls now shown on drawings. R-10 & R-21 <br /> respectively. R-38 for dormer roof is also noted. <br /> 14. Please see #13 above. <br /> 15. Please see page one for related information. <br /> Structural <br /> 1. The shear wall and diaphragm schedule has been included on page 1 of the <br /> drawing. Shear wall locations have been noted on the drawings. <br /> Please call or email if you have further questions. <br /> 1 <br /> Cordially, <br /> _I . t � '� <br /> Richard Sullivan <br /> Owner 2018 Grand Ave <br /> 425-259-2685 <br /> 2 �� <br />