Laserfiche WebLink
FLOOR PLAN NOTES ° Ea <br /> y <br /> I. CONTRACTOR SHALL VERIFY ALL NOTES,MATERIALS 4 CONDITIONS PRIOR TO I -D PER _ <br /> CONSTRUCTION. z„x nnnR TOW <br /> cortERm ax max <br /> WINDOW5 8 DOOR5: FR04T FO CH SLAB <br /> 2. ALL EXTERIOR WINDOW 4 DOOR HEADERS TO BE INSULATED w/R-10 INSULATION. <br /> 3. WINDOWS 4 DOORS ARE SHOWN 4 NOTED AS NOMINAL SIZES. <br /> 4. WINDOW THR <br /> HEAD HEIGHT R.O.SHOWN PER ELEVATIONS. EGRESS WINDOW SILL HEIGHT R.C.@ - ESIeLD <br /> RAI kD AI M (1nx4'a TO BE <br /> MAX.42"A.F.F. RIPPEE T REMOVED PRIOR DOOR 4 JAMB , <br /> 21 K' TO FRONT <br /> 5. ALL WOOD IN CONTACT WITH CONC. @ BE PRESSURE TREATED. - , TOE L STE'/WALK BEING CAULK BACK OF awl"' <br /> b. EXTERIOR WALLS TO BE 2x6 STUDS P 16"O.L.,U.NO. LDI T _N _ 4r_DOOR POURED THRESHOLD TO WRAP NERVASTRALd <br /> 7. GARAGE DOOR HEADERS @ 84'A.F.F. sL.x,FAPa. NERVESTRAL UP JAMB 6" <br /> 8. EXTERIOR SWING DOOR HEADERS @ 83 1/2'A.F.F, =ILw�u Z_ <ALL SEAMS <br /> 9. INTERIOR SWING DOOR HEADERS @ 83'A.F.F. Enc cD CAULK"UNDER °F <br /> 10. SWING DOORS TO FOLLOW CENTERLINE DIMENSION IN PLANS QR BE 3"f IF OIN HINGE SIDE. FrtoNt a TA.RAISED --_-- NERVESTRAL, I <br /> II, GARAGE-TO-HOUSE DOOR TO BE A SOLID WOOD I "THICK 20-MINUTE FIRE-RATED DOOR " "" ° �T SLOPE PORcu STEM WALL TO @ SIDES OF JAMB 6'-0' 4'-�° q'-3' 5'-0' 4'-BYzv <br /> w/A SELF CLOSING HARDWARE DEVICE. "`, Er 14'PER UN. STEM, T.O.FRONT PORCH WRAP EDGE 4 24°z36'NEAT <br /> 12. PER R3113.1 THE LANDING OR FLOOR ON THE EXTERIOR SIDE OF ALL EXTERIOR DOORS LEC( PT,MAX. STEM WALL•T THRESHOLD w/ <br /> EXCEPT THE FRONT DOOR SHALL BE NOT MORE THAN 7-3/4'BELOW THE TOP OF THE ADDL KERVASTRAL NERVA5TRAL OR EQ PUMP BASE. Q <br /> THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR _ WHEN GARAGE WI2 <br /> STEP <br /> ' 1 1 <br /> 13. ALL BI-FOLD 4 BI-PASS DOORS TO BE CENTERED,U.N.O. 'Rvl PORCH EXT. DETAIL � PRESHOLD DETAIL OPT.SELECTED, u-A <br /> 4 <br /> D� VERIFY LOCATION z <br /> r.,:I =ILO' J SCALE: I-I/2"=I'-0" w 3x3'6 CONIC. <br /> /SITE SUPER FRAMING: LANDING <br /> 14. VERIFY FIREPLACE 5TTLE 4 LOCATION w/SUPERVISOR PRIOR TO CON5T. �(� <br /> 15. FRAMERS TO INSTALL ALL WINDOWS 4 INTERIOR COLUMNS .4XO 5068 SGD(SG) ((-��� l�� <br /> 16' TOWEL RING BLK'G @ 57'A.F.F. LL 17. TOWEL BAR BLK'G @ 48'A.F.F.4 BLOCK BOTH BAYS. "Tn' 111AX01�0N <br /> ACTIVE <br /> Rnrt IxuR i ae+Aae MINI-5 LIT O <br /> IB. TOILET PAPER HOLDER BLK'G @ 22'A.F.F.AND 42°FROM BACK WALL WHERE POSSIBLE <br /> 19. THERMOSTAT BLK'G @ 60'A.F.F EQ. CPT" <br /> 20. EXTERIOR LIGHT BLOCKS AT ALL FRONT ENTRY'5 SHALL BE INSTALLED AT 7'-b'A.F.F. EGO PER PUN m H5 NOOK -�---1 v <br /> 21. THE TOP OF THE EXTERIOR LIGHT BLOCKS AT GARAGE SHALL ALIGN WITH TOP OF THE -ENABLE I FIXED <br /> GARAGE DOOR TRIM 7° <br /> 22. ADD CONT.BLOCKING FOR STAIR HANDRAIL BRACKETS K PAS'-.I ...I PANEL .......1 IO14xi3'6 �- <br /> 1 L <br /> 23. STAIRS /WINDER STEPS WILL ALWAYS HAVE A CONTINUOUS HANDRAIL INSTALLED ON �eR r - -�- ---------_ 216 REA)'HOOD CEDAR TRIM,THE I ICE OF THE STAIR'S RUN seNlur i F41.ALL s1DEs,uwwsEA1 cz <br /> - <br /> 2A. LADDER-BLOCK AT EXTERIOR WALLS AS NECE55ARY FOR INSULATION INSTALL x,rr I tW-{. .� EQ' GREAT ROOM <br /> ;3'r3'LWDIt ttP. D25 <br /> 0..A6AIN5T <br /> VENTILATION: NERv stRAL A9 _ <br /> PORCH PATIO C ELECTRIC 1517x17'7 T-6' <br /> I o <br /> 25. WHOLE HOUSE VENTILATION SHALL BE PROVIDED BY A CENTRAL EXHAUST FAN IN FIREPLACE <br /> 6'LANDING TYP. - <br /> ACCORDANCE WITH M1505.4.LI. exaa PAnO,RYAAp wore '^ <br /> v y ?BACK PATIOS ee rcuRm m ixe olRanw <br /> 26. WHOLE HOUSE FAN SHALL OPERATE CONTINUOUSLY. - sti.n e n e I' 34 H x Ea L W 024 WALL , R' <br /> 27. WHOLE HOUSE FAN CFM RATE BASED ON TABLE M1505.4.3(1).EXAMPLE:70 CFM FOR 2600 P E DRYWALL O4 SINK SIDE 6'-1'4 0 HALF IL <br /> 5F HOME w/4 BEDROOMS,AND THEN INCREASE BY FACTOR OF 1.5 PER TABLE "-216 AFARTYOOD CEDAR TRIM 2CM OVERHANGS TO BE 8"4 F' '3 M1505.4.3(2)TO ACCOUNT FOR NOT-BALANCED,NOT-DISTRIBUTED VENTILA-ION 5f5TEM. +A LANDING PER Pun'.PaR <br /> 28, WHOLE HOUSE FAN SHALL BE 1.0 BONES OR LESS,AND SHALL HAVE AN EFFI.ACC OF 2.8 _ AGAINST_ N°rvaT zx'HEARTWOOD CEDAR 3CM OVERHANGS TO BE 12" D/W I I" $ CENTER - <br /> TRIM:w FIASHING o STUD BAY <br /> CFM/WATT PER WSEC R403.6.1. ROE r<.I�` it --_ - -_---+ HOusE INTERSFcrION, I 1 �5 0SO <br /> 29. FRESH AIR SHALL BE INTRODUCED INTO THE HOUSE VIA OPERABLE WINDOW `R STATE IANgN>'PEv=uN ' rr+ERE GeCNRS a CM DWAIRGAP, ON RANGE <br /> CODE INTERPRETATION 17-15. 11N,:13'tYP:) _ 1 - H5 DW SIDE 4'-0'£ SEE CAB <br /> 30. PROVIDE A FRESH AIR TRANSFER GRILL ABOVE DOOR HEADER IN THE ROOM WITH THE aF BfEPS TBp Br jN- LINE CE NERVEstRAL ELECTRIC KITCHEN _ + LAYOFOR UT <br /> WHOLE HOUSE1FAN. lug �� ,_ E�cg+Dl�5 ` FIREPLACE OPT. 5'-11" 4'-4" 2'-IIV2' + 1 <br /> A v <br /> 31. OC <br /> PER IRO M1502.4.5.:WHERE THE DRYER VENT EXHAUST DUCT IS CONCEALED WITHIN THE 2xb WALL 8 5X�"-I"I ° .� <br /> BUILDING CONSTRUCTION,THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE l v 3- BF _. <br /> IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED ..,l _. µR SCALE: 1/4'•1'-0' T PANTRY <br /> HOOT,3' iv W/5(3) _______ LLR OPN'G <br /> WITHIN GIFT OF THE IXHAUST DUCT CONNECTION. <br /> • H 4Y"4 --2 1 e Y <br /> EX T -ANDING DETAIL @ Q LR ; -- <br /> 26. SAFETY: G GLASS DOOR TYP PWDR s0/co_ 7 <br /> 26. A HEAT ALARM OR HEAT DETECTOR RATED FOR AMBIENT OUTDOOR,TEMFERATURES AND ` J:_ 1 I _ 4°BOLLARD <br /> HUMIDITY TO BE CENTRALLY LOCATED IN THE GARAGE. i('V F - Tp z 5 Hs <br /> 27. THE HEAT ALARM OR HEAT DETECTOR WILL BE CONNECTED TO AN ALARM OR SMOKE \ ''--°�= S. o ":n CPT NOTE:HINT TO BE STALLED IN <br /> ALARM THAT IS INSTALLED IN THE DWELLING AND LOCATED IN A HALLWAY,ROOM OR T" 2668 THE 3rd CAR GARA(E OR <br /> OTHER LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION 2888 GARAGE BUMP-OUT WHEN THAT <br /> 10. SMOKE DETECTORS TO BE IIOV, INTERCONNECTED,w/BATTERY BACKUP 4 CENTRALLY T.IS SELECTED <br /> LOCATED IN EACH HABITABLE ROOM. ADDITIONAL SMOKE DETECTORS SHALL BE �---„ 24f0 <br /> INSTALLED WHERE THERE 15 A CEILING HEIGHT CHANGE GREATER THAN 24 4 `- i <br /> _ II. SMOKE DETECTORS SHALL BE INSTALLED NOT LESS THAN 3 FT HORIZONTALLY FROM THE <br /> DOOR OR OPENING OF A BATHROOM THAT CONTAINS TUB OR SHOWER.CR314) m '-- GARAGE <br /> 12. IONIZATION SMOKE ALARMS: Ia110x2014 1 V <br /> 4 SHALL NOT BE INSTALLED LE55 THAN 20 FT HORIZONTALLY FROM A PERMANENTLY �'R- 14T WRAP ALL WARM WALLS, POSTS, <br /> z INSTALLED COOKING APPLIANCE. N r oT BEAMS 4 SUPPORT WALLS W/1/2' <br /> 4 IONIZATION SMOKE ALARMS WITH AN ALARM-SILENCING SWITCH SHALL NOT BE INSTALLED n�' In G.W.B.4 5/8'TYPE'X"ON THE <br /> LESS THAN IO FT HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE. <br /> 24. PHOTO ELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED LESS THAN 6 FT .-�E' 4,_5' Irt ' 6-32" CEILING <br /> HORIZONTALLY DR4 X TOP EQUIREMENTS PERMANENTLY INSTALLED <br /> NRIM,LENTIREGARAGECOOKING <br /> PTO�:EET HUR SJICTION4 5�" Y 3WO HALF Y <br /> NCt[I�w <br /> 25.GARAGE NOTE:WRAP ALL WARN WALLS AND SUPPORTING MEMBER- ° <br /> COP I'RIWT NOTICE THIS <br /> TYPE FVG IS OWNED BY PACIFIC <br /> RIDGE 5WOMES.PRO14 USE OF THIS <br /> 26. ENCLOSED USABLE SPACE UNDER STAIRS TO BE PROTECTED WITH Jz"GWB AT THE _- sS' rr A-A/IC,D N41 4�I5 PPRAOTN'BBNT�r uw <br /> WALLS,UNDER-STAIR SURFACES AND SOFFITS. IC <br /> I _.._ <br /> 27. PROVIDE FIREBLOCKING PER PLAN AND @ALL PLUMBING PENETRATIONS, RME HOMES,36'TALL <br /> - U <br /> PONY WALL LAYOUT, PLAN SUMMARY <br /> ENTRY 3T ENTRY SEE wa ea n e asen n n.. <br /> 3 n IT NIA <br /> I A4 UP g UP <br /> 1. MR,�m <br /> _ ___.__ m I :n m a 16R T 3 851 <br /> ' i° A4 wce ore w.A. <br /> 15070 GARAGE DOOR 1251 <br /> -r TorAL MG m n., <br /> LINE OF FLOOR ABOVE ---- 2102 <br /> FRONT SORGH % GH q3o� <br /> CON L � - our soala. <br /> - Iraf NT I­ ELECTRIC w SOFFIT DOWN TO .aaIgA A.rws wvuw <br /> BTM OF BEAM JWA <br /> I I STEP P l0 IB" 7 u srP UP 18° 2, FOR LAN LIGHT I spy, <br /> STEP P I W2" B'fL ENGINEERING <br /> 10- <br /> SEE REVISION LOG <br /> 24V,4' �A <br /> - SCALE:Y" = 1'-0" <br /> 'm EXTENDED FRONT PORC✓-I D q <br /> DRIVEWAY WIDTH OPTION - 'C' $ 'D' ELEV.'s: MAIN FLOOR PLAN <br /> ENAY/PORCH PLAN_ SCALE: I/4"-I'-0" MAIN FLOOR PLAN: 'C' 'D' ELEV's <br /> SCALE: 3/B'-I'-0' /4 4 <br /> SCALE: I/4'=I'-0' <br /> ('C' 8 'D' ELEV's) <br />