Laserfiche WebLink
FLOOR PLAN NOTES <br /> I. CONTRACTOR SHALL VERIFY ALL NOTES,MATLRIAL5 t CGNDITION5 PRIOR TO <br /> CONSTRUCTION. <br /> WINDOWS 4 DOORS: <br /> 2. ALL EXTERIOR WINDOW t DOOR HEADERS TO BE INSULA-,ED w/R-10 INSULATION. <br /> 3. WINDOWS t DOOR$ARE SHOWN t NOTED AS NOMINAL SIZES. <br /> 4. WINDOW HEAD HEIGHT R.O.SHOWN PER ELEVATIONS, EGRESS WINDOW SILL HEIGHT R.O.:+ <br /> MAX.42'A.F.F. <br /> 5. ALL WOOD IN CONTACT WITH CONC.TO BE PRESSURE TREATED. �'"0, <br /> 6. EXTERIOR WALLS TO BE 2x6 STUDS @ 16,QC.,U.NO. 14'-I' <br /> 7. GARAGE DOOR HEADERS @ 84'A.F.F. 4'-7' <br /> 8. EXTERIOR SWING DOOR HEADERS @ 83 1/2"A F,F. <br /> 9. INTERIOR SWING DOOR HEADERS @ 83'A.F.F. 5'-2' 4'-0' 4-II' V-7" 2'-0' 3'-6?' 4-0' 3'-8%, <br /> 10. SWING DOORS TO FOLLOW CENTERLINE DIMENSION IN PLANS OR BE 3"MIN,ON HINGE SIDE. <br /> 11. GARAGE-TO-HOUSE DOOR TO BE A SOLID WOOD IV THICK 20-MINUTE FIRE-RATED DOOR { - <br /> w/A SELF CLOSING HARDWARE DEVICE. Q <br /> 12. PER R311.3.1:THE LANDING OR FLOOR ON THE Ex rERiOR SIDE OF ALL EXTERIOR DJORS 1 1 1 <br /> U <br /> EXCEPT THE FRONT DOOR SHALL BE NOT MORE THAN 7-5/4"BELOW THE TOP OF THE L <br /> THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR T <br /> 13, ALL BI-FOLD t 51-PASS DOORS TO BE CENTERED,UA C. :T <br /> FRAMING: 4040 XO 4040 XO �( <br /> C: (EGRESS) (EGRESS) (-L1 <br /> 14. VERIFY FIREPLACE STYLE t LOCATION w/SUPERVISOR iZ,OR TO CON5T. <br /> 15. FRAMERS TO INSTALL ALL WINDOWS t INTERIOR COLUMNS EQ. :E0. 1-1L <br /> 16. TOWEL RING BLK'G @ 57'A.F.F. <br /> I � <br /> 17. TOWEL BAR BLK'G @ 48"A.F.F.t 13LGCK BOTH BAY5. 1 ' 1 , I <br /> kJ <br /> _ <br /> 18. TOILET PAPER HOLDER BLK'G @ 22'A.F.F.AND 42"FROM BACK WALL WHERE POSSIBLE I ' <br /> A THERMOSTAT BLK'G @ 60'A.F.F <br /> 20, EXTERIOR LIGHT BLOCKS AT ALL FRONT ENTRY'S SHALL BE 15TALLED AT T-6"A.F.F. - <br /> 21. THE TOP OF THE EXTERIOR LIGHT BLOCKS AT GARAGE SHALL ALIGN WITH TOP OF THE BEDROOM 3� 1 <br /> GARAGE DOOR TRIM I BEDROOM <br /> 22, ADD CONT.BLOCKING FOR STAIR HANDRAIL BRACKETS - 10 5XI3 8 <br /> 23. STAIRS w/WINDER STEPS WILL ALWAYS HAVE A CU4TIN000S HANDRAIL INSTALLED ON E0, EO 1017X12'0 - < <br /> THE INSIDE OF THE STAIR's RUN DOUBLE RIM OR <br /> 24, LADDER-BLOCK AT EXTERIOR WALLS AS NE,;ES5ARY FCR H450L1TION INSTALL PROVIDE SPLICE QSD <br /> VENTILATION: <br /> 25. WHOLE HOUSE VENTILATION SHALL BE PROVIDED BY A CENTRAL EXHAUST FAN IN MINI-SPLIT 2668 <br /> ACCORDANCE WITH M1505.4.1.1. <br /> 26. WHOLE HOUSE FAN SHALL OPERATE CON1"INUGUSLY. 2x6 WALL MINI-SPLIT q1D <br /> 2668MINI-SPLIT 2x6 WALL <br /> 27. WHOLE HOUSE FAN CFM RATE BASED ON TABLE M1505.4.3(1),EXAMPLE 70 CFM FOR 2600SF HOME w/4 BEDROOMS,AND THEN INCREASE BY FACTOR OF 1.5 PER TABLE ADD FLAT 2668 BATHM1505.4.3(2)TO ACCOUNT FOR NOT-BALANCED, NOT-DISTRIBUTED VENTILATION 5Y5 TEMi 2X4 THROUGH CPT 2B. WHOLE HOUSE FAN SHALL BE 1.0 SONES OR LE55, AND SHALL HAVE AN EFFICACY OF 2.8 JOIST @ 5'O,C. V xb H560"x32CFM/WATT PER WSEC R403.6.1. BEDROOM 25 63�_ TuRTe29. FRESH AIR SHALL BE INTRODUCED INTO THE HOUSE VIA 0"rERA6LE WINDOWS PER STATE CODE INTERPRETATION 17-I5. Y�Xw - - 1018XI3184,_ 4B®TY 2 3'- ' <br /> 30. PROVIDE A FRESH AIR TRANSFER GRILL ABOVE DOOR HEADER IN THE ROOM WITH THE - <br /> WHOLE HOUSE FAN. k TRANSFER i <br /> 31. PER IRC M1502.4.5,:WHERE THE DRYER VENT EXHAUST DUCT IS CONCEALED WITHIN THE _- GRILL ABO 2x6 WALL <br /> BUILDING CONSTRUCTION,THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE STT 14R5416Z. DOOR <br /> IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED ATTACH TO SECTION THRU - 8'-5' 5'W S UTILITY <br /> WITHIN EFT OF THE EXHAUST DUCT CONNECTION WALL CAP - <br /> 2x AND TO SD/CO- cPr -Cl_, 1 I DRYER <br /> AIR RIM 5/o eF T HB nirlc 5 X7 VENT @ <br /> LIFE SAFETY: ACCF55 WHOLED 60"pFF <br /> 26. A HEAT ALARM OR HEAT DETECTOR RATED FOR AMBIENT OUTDOOR"TEMPERATURES AND - E' LINEN m FOUSE VTO91 <br /> v O <br /> m , <br /> HUMIDITY TO BE CENTRALLY LOCATED IN THE GARAGE Y;, --------W/5(1�------- W/5(3) it <br /> 27. THE HEAT ALARM OR HEAT DETECTOR WILL BE CONN"cCTEO TO AN ALARM OR SMOKE <br /> ALARM THAT 15 INSTALLED IN THE DWELLING AND LOCATED IN A HALLWAY,ROOM OR Ll-2Y4' <br /> -------------� - <br /> OTHER LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION _ _ V-6' _ 10'-3'�' 4/0 OF 4,_ _ WIO I^10. SMOKE DETECTORS TO BE IIOV,INTERCONNECTED,w/BATTERY BACKUP t CENTRALLY HALF WALL FRAMING CAP DETAIL _ 1 QLOCATED IN EACH HABITABLE ROOM. ADDITIONAL SMOKE DETECTORS SHALL BE D15 scale: ,,I_o.� pN D15 m 9X10 7INSTALLED WHERE THERE 15 A CEILING HEIGHT CHANGE GREATER THAN 24 15R,I4T A54'-4 <br /> 11. SMOKE DETECTORS SHALL BE INSTALLED 'till LESS THAN 3 FT HORIZONTALLT FROM 1HL uUDOOR OR OPENING OF A BATHROOM THAT CONTAINS TUB OR SHOWER.IR3141 CL ;id <br /> 12. IONIZATION SMOKE ALARMS: - 'r IG TECEO SHALL NOT BE INSTALLED LE55 THAN 20 Fl"HORIZONTALLY FROM A PERMANENTLY u"� f NICHEINSTALLED COOKING APPLIANCE. -PROVIDE MIN.30' ATTIC ACCESS nr �+ m <br /> + IONIZATION SMOKE ALARMS WITH AN ALARM-51LE14CING 5WITCH SHALL NOT BE INSTALLED a QSD <br /> LE55 THAN 10 FT HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE. HEADROIXI CLEARANCE. SHEATHING ON R a <br /> 24. PHOTO ELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED LESS THAN 6 FT -TRUSSES MUST BE OUTSIDE OF sT m <br /> INSTALLED @ 24'O.C. TRU55 MEMBERS uT ® � 2468 g ca'YRlcur NOTICE,n+ls <br /> HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE IR3141 - - PL,UI 15 OWNED BY PACIFIC <br /> 25.GARAGE NOTE:WRAP ALL WARM WALLS AND SUPPORTING MEMBERS WITH 1/2'G.W.B.t 6/8' RIME Hates.USE OF THIS <br /> TYPE'X'ON THE CEILING.POLY SEAL RIM, ENTIRE GARAGE TO MEET JURISDICTION P �1 6T > 2 0e PL.LN 15 PROHIBITED BY LAN <br /> DRAFT STOP REQUIREMENTS ® � BATH I W WIl'NPJT PAYMENT OF <br /> " BDRM I RIME <br /> FEE TO PACIFIC <br /> 26, ENCLOSED USABLE SPACE UNDER STAIRS 1"0 BE PROTECTED WTfH h GW5 AT THE `I R Rur.E W111P5. <br /> HALLS,UNDER-STAIR SURFACES AND SOFFITS. ! IOIXI0'7 CPT i <br /> 27, PROVIDE FIREBLOCKING PER PLAN AND @ ALL PLUMBING PENETRATIONS. 'IT -0, 2'10 13 3X15 _ F'LAN SUMMARY <br /> 5/4 TRIM GWB ATTIC °f 668 la,.,cameue.,,sa Fr.. <br /> OR SIM, ACCESS LID 'sT ,x " <br /> ATTIC ACCESS DETAIL <br /> EE 12 2'-B' <br /> D39 3 <br /> SCALE:I/2' I'-0' <br /> '^ umx uus <br /> 1251 <br /> 2030 2630 S.H. <br /> Plc (SG, - 2102 <br /> 055) 804E XOX <br /> (EGRESS) 430 <br /> ELECTRIC <br /> 9' .wanauu"nre omm,uTe. <br /> J14A <br /> 14Y 2'-0' Vz" V-6' V-2, <br /> BTL ENGINEERING <br /> 3'-6' 6'-7y' 3'-Illy" 8'-0" 3'-IVR' menu <br /> SEE REVISION LOG <br /> 14-1' 15'-I1' <br /> SCALE:y"= I'-O" <br /> UPPER FLOOR PLAN <br /> UPPER FLOOR PLAN: 'C' I 'D' ELEV. <br /> SCALE: 1/4'=V-0' <br /> ('.:' If 'D' ELEV'5) <br />