Laserfiche WebLink
APage 11 <br /> DATE: 3/30/2022 COMPANY: American Home Planners <br /> VITRUVIUS BUILD: StruCalc DESIGNED BY: L V <br /> CUSTOMER: Carlisle Residence REVIEWED BY: L V <br /> PROD.ADDRESS: -- PROJECT NAME: Carlisle Residence <br /> LEVEL Roof LOADING: ASD <br /> MEMBER NAME: 8FtGirderTruss@CovBalcony CODE: 2018 International Building Code <br /> MEMBER TYPE: ROOF BEAM NDS: 2018 NDS <br /> MATERIAL Solid Sawn <br /> Douglas Fir-Larch No.2 (1)3.5 X 9.25 DRY <br /> f •- • • • <br /> T�7 j <br /> I I <br /> I $. <br /> Start(ft):0 End(ft):8 Member Slope:0/12 Actual Length(ft):8 <br /> Area Ix ly BSW Lams G Kcr <br /> (in') pn•) (in) (Ibf/ft) Creep Factor <br /> 32.38 230.84 33.05 7.38 1 OS 1 <br /> Fb(psi) Ft(psi) Fv(psi) Fc(psi) Fc-L(psi) E(psi)x103 Emin(psi)x103 <br /> Base Values 900 575 180 1350 625 1600 580 <br /> Adjusted Values 1080 632 180 1350 625 1600 580 <br /> CM 1 1 1 1 1 1 1 <br /> CT 1 1 1 1 1 1 1 <br /> Ci 1 1 1 1 1 1 1 <br /> CF 1.2 1.1 1 1 1 1 1 <br /> Bending Adjustment Factors Cfu=1 Cr=1 <br /> Unbraced Length(ft) Beam End <br /> Span Length(ft) Top Bottom Elev.Diff(ft) CL(Top) CL(Bottom) CL(Left) CL(Right) <br /> 1 8 0 8 0 1.00 0.99 1.00 1.00 <br /> PASS/FAIL MAGNITUDE STRENGTH LOCATION(ft) LOAD COMBO DURATION FACTOR CD <br /> Shear Stress Y(psi) PASS (56.6%) 97.7 225.0 0 D+Lr 1.25 <br /> Bending Stress Y(psi) PASS(24.9%) 1014.4 1350.0 4 D+Lr 1.25 <br /> Deflection(in) PASS(75.3%) 0.132(=L/729) 0.533(=L/180) 4 D+Lr <br /> Bearing Stress(psi) PASS(72.4%) 172.2 625.0 0 D+Lr 1.25 <br /> • • Units for V:Ibf Units for M:Ibf-ft <br /> Y axis DEAD LIVE LIVE ROOF SNOW WIND+ WIND- SEISMIC+ SEISMIC- ICE RAIN EARTH <br /> A 810 0 1300 0 0 0 0 0 0 0 0 <br /> B 810 0 1300 0 0 0 0 0 0 0 0 <br /> Reaction Location <br /> A B <br /> PROJECT:Carlisle Residence 2018 International Building Code ASD <br />